DICOM PS3.17 2022a - Explanatory Information

N.3.12 Right Ventricle

Name of ASE Concept

Base Measurement Concept Name

Concept or Acquisition Context Modifiers

Right Ventricular Internal Diastolic Dimension by M-Mode

(20304-2, LN, "Right Ventricular Internal Diastolic Dimension")

(399264008, SCT, "Image Mode") = (399155008, SCT, "M mode")

Right Ventricular Internal Diastolic Dimension by 2-D

(20304-2, LN, "Right Ventricular Internal Diastolic Dimension")

(399264008, SCT, "Image Mode") = (399064001, SCT, "2D mode")

Right Ventricular Outflow Tract Systolic Peak Velocity

(11726-7, LN, "Peak Velocity")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricular Outflow Tract Systolic Velocity Time Integral

(20354-7, LN, "Velocity Time Integral")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricular Outflow Systolic Diameter by 2-D

(399027007, SCT, "Cardiovascular Orifice Diameter")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

(399264008, SCT, "Image Mode") = (399064001, SCT, "2D mode")

Right Ventricular Outflow Tract Systolic Peak Instantaneous Gradient

(20247-3, LN, "Peak Gradient")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricular Outflow Tract Systolic Mean Gradient

(20256-4, LN, "Mean Gradient")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricular Stroke Volume by Doppler Volume Outflow

(90096001, SCT, "Stroke Volume")

(370129005, SCT, "Measurement Method") = (125219, DCM, "Doppler Volume Flow") (363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricular Outflow Tract Area

(399367004, SCT, "Cardiovascular Orifice Area")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricular Outflow Tract Mean Velocity

(20352-1, LN, "Mean Velocity")

(363698007, SCT, "Finding Site") = (44627009, SCT, "Right Ventricular Outflow Tract")

Right Ventricle Anterior Wall Diastolic Thickness

(18153-7, LN, "Right Ventricle Anterior Wall Diastolic Thickness")

Right Ventricular Anterior Wall Systolic Thickness

(18157-8, LN, "Right Ventricular Anterior Wall Systolic Thickness")

Right Ventricular Peak Systolic Pressure

(399023006, SCT, "Right Ventricular Peak Systolic Pressure")

DICOM PS3.17 2022a - Explanatory Information