DICOM PS3.16 2022a - Content Mapping Resource

TID 4207 Breast Imaging Pathology Results

This Template defines the pathology results for a procedure. It may be applied to a Breast Imaging Assessment (see TID 4203 “Breast Imaging Assessment”), or a Breast Imaging Intervention (see TID 4204 “Breast Imaging Report Intervention Section”).

Type:

Extensible

Order:

Significant

Root:

No

Table TID 4207. Breast Imaging Pathology Results

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111468, DCM, "Pathology Results")

1

M

2

>

CONTAINS

INCLUDE

DTID 4201 “Breast Imaging Procedure Reported”

1

U

3

>

CONTAINS

DATETIME

EV (111469, DCM, "Sampling DateTime")

1

M

4

>

CONTAINS

CODE

EV (122177, DCM, "Procedure Result")

1

M

DCID 6063 “Interventional Procedure Results”

5

>

CONTAINS

CODE

EV (111042, DCM, "Pathology")

1-n

U

BCID 6030 “Mammography Pathology Codes”

6

>>

HAS PROPERTIES

CODE

EV (111388, DCM, "Malignancy Type")

1

U

DCID 6159 “Malignancy Type”

7

>>

HAS PROPERTIES

NUM

DCID 6165 “Breast Linear Measurements”

1-n

U

UNITS = EV (mm, UCUM, "millimeter")

8

>>

HAS PROPERTIES

CODE

EV (373372005, SCT, "Histological grade finding")

1

U

BCID 6069 “Nottingham Combined Histologic Grade”

BCID 6070 “Bloom-Richardson Histologic Grade”

9

>>>

HAS CONCEPT MOD

CODE

EV (371469007, SCT, "Histologic grade")

1

U

BCID 6071 “Histologic Grading Method”

10

>>

HAS PROPERTIES

CODE

EV (372249001, SCT, "Tumor margin status")

1

U

DT (111470, DCM, "Uninvolved"),

DT (111471, DCM, "Involved")

11

>>

HAS PROPERTIES

CODE

EV (111472, DCM, "Nipple involved")

1

U

DCID 230 “Yes-No”

12

>>

HAS PROPERTIES

NUM

EV (111473, DCM, "Number of nodes removed")

1

U

UNITS = EV ({nodes}, UCUM, "nodes")

13

>>

HAS PROPERTIES

NUM

EV (111474, DCM, "Number of nodes positive")

1

MC

Shall be present IFF value of row 12 is > 0

UNITS = EV ({nodes}, UCUM, "nodes")

14

>>

HAS PROPERTIES

CODE

EV (385385001, SCT, "pT category finding")

1

U

DCID 6160 “Breast Primary Tumor Assessment From AJCC”

15

>>

HAS PROPERTIES

CODE

EV (385382003, SCT, "Node stage finding")

1

U

DCID 6161 “Clinical Regional Lymph Node Assessment for Breast”

16

>>

HAS PROPERTIES

CODE

EV (385380006, SCT, "Metastasis stage finding")

1

U

DCID 6162 “Assessment of Metastasis for Breast”

17

>>

HAS PROPERTIES

CODE

EV (385356007, SCT, "Tumor stage finding")

1

U

BCID 6068 “Tumor Stages From AJCC”

18

>>

HAS PROPERTIES

CODE

EV (111475, DCM, "Estrogen receptor")

1

U

DCID 250 “Positive-Negative”

19

>>

HAS PROPERTIES

CODE

EV (111476, DCM, "Progesterone receptor")

1

U

DCID 250 “Positive-Negative”

20

>>

HAS PROPERTIES

NUM

EV (111477, DCM, "S Phase")

1

U

UNITS = EV (%, UCUM, "percent")

21

>>

HAS PROPERTIES

CODE

EV (48676-1, LN, "HER2")

1

U

DCID 250 “Positive-Negative”


DICOM PS3.16 2022a - Content Mapping Resource