DICOM PS3.16 2022a - Content Mapping Resource

TID 3912 Stenosis Properties

Properties of a stenosis finding

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3912. Stenosis Properties

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

HAS PROPERTIES

CODE

EV (370129005, SCT, "Measurement method")

1

M

DCID 3804 “Stenosis Measurement Methods”

2

HAS PROPERTIES

CODE

EV (246244004, SCT, "Type of Stenosis")

1

U

DCID 3805 “Stenosis Types”

3

HAS PROPERTIES

CODE

EV (47429007, SCT, "Associated with")

1

U

DCID 3815 “Source of Vascular Finding”

4

HAS PROPERTIES

CODE

EV (300842002, SCT, "Shape")

1

U

DCID 3806 “Stenosis Shape”

5

HAS PROPERTIES

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = EV (397413000, SCT, "Vessel Lumen Diameter")

$Derivation = DCID 3488 “Min/Max/Mean”

$Units = DT (mm, UCUM, "mm")

6

HAS PROPERTIES

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = EV (397415007, SCT, "Vessel Lumen Cross-Sectional Area")

$Derivation = DCID 3488 “Min/Max/Mean”

$Units = DT (mm2, UCUM, "mm2")

7

HAS PROPERTIES

NUM

EV (408716009, SCT, "Stenotic Lesion Length")

1

U

UNITS = DT (mm, UCUM, "mm")

8

HAS PROPERTIES

CODE

EV (408716009, SCT, "Stenotic Lesion Length")

1

U

DCID 3831 “Stenosis Length”

9

HAS PROPERTIES

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = EV (408714007, SCT, "Lumen Area Stenosis")

$Derivation = DCID 3488 “Min/Max/Mean”

$Units = DT (%, UCUM, "%")

10

HAS PROPERTIES

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = EV (408715008, SCT, "Lumen Diameter stenosis")

$Derivation = DCID 3488 “Min/Max/Mean”

$Units = DT (%, UCUM, "%")

11

HAS PROPERTIES

CODE

EV (408714007, SCT, "Lumen Area Stenosis")

1-n

U

DCID 3832 “Stenosis Grade”

12

>

HAS CONCEPT MOD

CODE

EV (121401, DCM, "Derivation")

1

M

DCID 3488 “Min/Max/Mean”

13

HAS PROPERTIES

CODE

EV (408715008, SCT, "Lumen Diameter Stenosis")

1-n

U

DCID 3832 “Stenosis Grade”

14

>

HAS CONCEPT MOD

CODE

EV (121401, DCM, "Derivation")

1

M

DCID 3488 “Min/Max/Mean”


DICOM PS3.16 2022a - Content Mapping Resource