DICOM PS3.16 2022a - Content Mapping Resource

TID 3802 Cardiovascular Patient History

This Template contains information about a cardiovascular patient's past medical history that is relevant for the interpretation of the SR document of which it is part. This information is considered to have some degree of "persistence" across different episodes of care.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3802. Cardiovascular Patient History

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (11329-0, LN, "History")

1

M

2

>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1

U

3

>

CONTAINS

CONTAINER

DT (11450-4, LN, "Problem List")

1

U

4

>>

CONTAINS

TEXT

DCID 3769 “Concern Types”

1-n

U

5

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1-n

U

$Problem = DCID 3756 “Cardiac Patient Risk Factors”

6

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1

U

$Problem = EV (161445009, SCT, "History of Diabetes mellitus")

$Therapy = DCID 3722 “Diabetic Therapy”

7

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1

U

$Problem = EV (161501007, SCT, "History of Hypertension")

$Therapy = DCID 3760 “Hypertension Therapy”

8

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1

U

$Problem = EV (414416008, SCT, "History of Hypercholesterolemia")

$Therapy = DCID 3761 “Antilipemic Agents”

9

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1

U

$Problem = EV (44808001, SCT, "Arrhythmia")

$Therapy = DCID 3762 “Antiarrhythmic Agents”

10

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1

U

$Problem = EV (399211009, SCT, "History of Myocardial infarction")

$ModType = DT (122170, DCM, "Type of Myocardial Infarction")

$ModValue = DCID 3723 “MI Types”

$Therapy = DCID 3764 “Myocardial Infarction Therapies”

11

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1

U

$Problem = EV (275552000, SCT, "History of Kidney disease")

$Stage = DCID 3778 “Stages”

12

>

CONTAINS

CONTAINER

DT (29762-2, LN, "Social History")

1

U

13

>>

CONTAINS

TEXT

EV (160476009, SCT, "Social History")

1

U

14

>>

CONTAINS

TEXT

DCID 3774 “Social History”

1-n

U

15

>>

CONTAINS

CODE

EV (365981007, SCT, "Tobacco Smoking Behavior")

1

U

DCID 3724 “Smoking History”

16

>>

CONTAINS

CODE

DT (228366006, SCT, "Drug misuse behavior")

1

U

DT (78267003, SCT, "Cocaine Abuse")

17

>

CONTAINS

CONTAINER

DT (10167-5, LN, "Past Surgical History")

1

U

18

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1-n

U

19

>>

CONTAINS

INCLUDE

DTID 3830 “Procedure Properties”

1-n

U

$ProcType = DT (387713003, SCT, "Surgical Procedure")

$Procedure = DCID 3721 “Cardiovascular Surgeries”

20

>

CONTAINS

CONTAINER

DT (30954-2, LN, "Relevant Diagnostic Tests and/or Laboratory Data")

1

U

21

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1-n

U

22

>>

CONTAINS

INCLUDE

DTID 3830 “Procedure Properties”

1-n

U

$ProcType = DT (103693007, SCT, "Diagnostic procedure")

$Procedure = DCID 3757 “Cardiac Diagnostic Procedures”

23

>>

CONTAINS

NUM

DT (2086-7, LN, "Cholesterol.in HDL")

1

U

UNITS = EV (mg/dl, UCUM, "mg/dl")

24

>>

CONTAINS

NUM

DT (2089-1, LN, "Cholesterol.in LDL")

1

U

UNITS = EV (mg/dl, UCUM, "mg/dl")

25

>

CONTAINS

CONTAINER

DT (10160-0, LN, "History of Medication Use")

1

U

26

>>

CONTAINS

TEXT

DT (111516, DCM, "Medication Type")

1-n

U

27

>>>

HAS PROPERTIES

CODE

DT (33999-4, LN, "Status")

1

U

DCID 3773 “Use Status”

28

>>

CONTAINS

CODE

DT (111516, DCM, "Medication Type")

1-n

U

29

>>>

HAS PROPERTIES

NUM

DT (260911001, SCT, "Dosage")

1

U

30

>>>

HAS PROPERTIES

CODE

DT (33999-4, LN, "Status")

1

U

DCID 3773 “Use Status”

31

>

CONTAINS

CONTAINER

DT (10157-6, LN, "History of Family Member Diseases")

1

U

32

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1-n

U

33

>>

CONTAINS

CODE

EV (416471007, SCT, "Family history of clinical finding")

1-n

U

DCID 3758 “Cardiovascular Family History”

34

>>>

HAS PROPERTIES

CODE

EV (408732007, SCT, "Subject relationship")

1

M

DCID 7451 “Family Member”

35

>

CONTAINS

CONTAINER

DT (46264-8, LN, "History of medical device use")

1

U

36

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1

U

37

>>

CONTAINS

INCLUDE

DTID 3831 “Medical Device Use”

1-n

U

$Device = DCID 3777 “Implanted Devices”


DICOM PS3.16 2022a - Content Mapping Resource