| DICOM PS3.16 2022a - Content Mapping Resource |
|---|
The Arterial Pressure Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing systolic, diastolic, and mean measurements. This implies that the name of the measurement is effectively post-coordinated from the measurement name, the Hemodynamic Measurement Group container (procedure phase) name, and the acquisition context (finding site) value.
Table TID 3504. Arterial Pressure Measurement
|
$LocationName = EV (363698007, SCT, "Finding Site") $LocationValue = DCID 3606 “Arterial Source Locations” |
||||||||
|
$Measurement = EV (8480-6, LN, "Intravascular arterial Systolic pressure") $Units = DCID 3500 “Pressure Units” |
||||||||
|
$Measurement = EV (8462-4, LN, "Intravascular arterial Diastolic pressure") $Units = DCID 3500 “Pressure Units” |
||||||||
|
$Measurement = EV (8478-0, LN, "Intravascular arterial mean pressure") $Units = DCID 3500 “Pressure Units” |
||||||||
| DICOM PS3.16 2022a - Content Mapping Resource |
|---|