1
|
|
|
CONTAINER
|
EV (59776-5, LN, "Findings")
|
1
|
M
|
|
|
|
2
|
>
|
HAS CONCEPT MOD
|
CODE
|
EV (363698007, SCT, "Finding Site")
|
1
|
M
|
|
DCID 3604 “Arterial Lesion Locations”
|
|
3
|
>
|
CONTAINS
|
IMAGE
|
EV (121112, DCM, "Source of Measurement")
|
1
|
M
|
|
|
|
4
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3205 “Calibration”
|
1
|
M
|
|
|
|
5
|
>
|
HAS ACQ CONTEXT
|
INCLUDE
|
DTID 3520 “Hemodynamic Clinical Context”
|
1
|
U
|
|
|
|
6
|
>
|
HAS ACQ CONTEXT
|
CODE
|
EV (129085009, SCT, "Catheterization Procedure Phase")
|
1
|
U
|
|
DCID 3651 “Hemodynamic Measurement Phase”
|
|
7
|
>
|
CONTAINS
|
SCOORD
|
EV (122507, DCM, "Left Contour")
|
1
|
M
|
|
GRAPHIC TYPE = {POLYLINE}
|
|
8
|
>>
|
R-SELECTED FROM
|
IMAGE
|
|
1
|
M
|
|
Must reference Row 3
|
|
9
|
>
|
CONTAINS
|
SCOORD
|
EV (122508, DCM, "Right Contour")
|
1
|
M
|
|
GRAPHIC TYPE = {POLYLINE}
|
|
10
|
>>
|
R-SELECTED FROM
|
IMAGE
|
|
1
|
M
|
|
Must reference Row 3
|
|
11
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3219 “Segment Values”
|
1
|
M
|
|
|
|
12
|
>
|
CONTAINS
|
INCLUDE
|
DTID 300 “Measurement”
|
1
|
M
|
|
$Measurement = EV (397413000, SCT, "Vessel Luminal Diameter")
$Derivation = EV (255605001, SCT, "Minimum")
$Units = DT (mm, UCUM, "mm")
|
|
13
|
>
|
CONTAINS
|
INCLUDE
|
DTID 300 “Measurement”
|
1
|
M
|
|
$Measurement = EV (397413000, SCT, "Vessel Luminal Diameter")
$Derivation = EV (56851009, SCT, "Maximum")
$Units = DT (mm, UCUM, "mm")
|
|
14
|
>
|
CONTAINS
|
CONTAINER
|
EV (122509, DCM, "Diameter Graph")
|
1
|
U
|
|
|
|
15
|
>>
|
CONTAINS
|
NUM
|
EV (122511, DCM, "Graph Increment")
|
1
|
M
|
|
Value = 1
UNITS = DT ({pixels}, UCUM, "pixels")
|
|
16
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 300 “Measurement”
|
1-n
|
M
|
|
$Measurement = EV (397413000, SCT, "Vessel Luminal Diameter")
$Units = DT (mm, UCUM, "mm")
|
|
17
|
>
|
CONTAINS
|
NUM
|
EV (122382, DCM, "Site of Luminal Minimum")
|
1
|
U
|
|
UNITS = DT ({pixels}, UCUM, "pixels")
|
|
18
|
>
|
CONTAINS
|
NUM
|
EV (122516, DCM, "Site of Luminal Maximum")
|
1
|
U
|
|
UNITS = DT ({pixels}, UCUM, "pixels")
|
|
19
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3215 “Angiographic Lesion Analysis”
|
1-n
|
U
|
|
|
|
20
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3217 “Sub-segmental Data”
|
1-n
|
U
|
|
|
|
21
|
>
|
CONTAINS
|
IMAGE
|
|
1
|
U
|
|
|