1
|
|
|
CONTAINER
|
EV (125200, DCM, "Adult Echocardiography Procedure Report")
|
1
|
M
|
|
Root node
|
|
2
|
>
|
HAS CONCEPT MOD
|
INCLUDE
|
DTID 1204 “Language of Content Item and Descendants”
|
1
|
U
|
|
|
|
3
|
>
|
HAS OBS CONTEXT
|
INCLUDE
|
DTID 1001 “Observation Context”
|
1
|
M
|
|
|
|
4
|
>
|
CONTAINS
|
CONTAINER
|
DT (55111-9, LN, "Current Procedure Descriptions")
|
1
|
U
|
|
|
|
5
|
>>
|
CONTAINS
|
CODE
|
DT (125203, DCM, "Acquisition Protocol")
|
1-n
|
M
|
|
BCID 12001 “Ultrasound Protocol Types”
|
|
6
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5201 “Echocardiography Patient Characteristics”
|
1
|
U
|
|
|
|
7
|
>
|
CONTAINS
|
CONTAINER
|
EV (111028, DCM, "Image Library")
|
1
|
U
|
|
|
|
8
|
>>
|
CONTAINS
|
IMAGE
|
|
1-n
|
M
|
|
|
|
9
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (87878005, SCT, "Left Ventricle")
$MeasType = DCID 12200 “Echocardiography Left Ventricle”
|
|
10
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (53085002, SCT, "Right Ventricle")
$MeasType = DCID 12204 “Echocardiography Right Ventricle”
|
|
11
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (82471001, SCT, "Left Atrium")
$MeasType = DCID 12205 “Echocardiography Left Atrium”
|
|
12
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (73829009, SCT, "Right Atrium")
$MeasType = DCID 12206 “Echocardiography Right Atrium”
|
|
13
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (34202007, SCT, "Aortic Valve")
$MeasType = DCID 12211 “Echocardiography Aortic Valve”
|
|
14
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (91134007, SCT, "Mitral Valve")
$MeasType = DCID 12207 “Echocardiography Mitral Valve”
|
|
15
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (39057004, SCT, "Pulmonic Valve")
$MeasType = DCID 12209 “Echocardiography Pulmonic Valve”
|
|
16
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (46030003, SCT, "Tricuspid Valve")
$MeasType = DCID 12208 “Echocardiography Tricuspid Valve”
|
|
17
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (15825003, SCT, "Aorta")
$MeasType = DCID 12212 “Echocardiography Aorta”
|
|
18
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (81040000, SCT, "Pulmonary artery")
$MeasType = DCID 12210 “Echocardiography Pulmonary Artery”
|
|
19
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (35532006, SCT, "Vena Cava")
$MeasType = DCID 12215 “Echocardiography Vena Cavae”
|
|
20
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (122972007, SCT, "Pulmonary Venous Structure")
$MeasType = DCID 12214 “Echocardiography Pulmonary Veins”
|
|
21
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (25489000, SCT, "Pericardial cavity")
$MeasType = DCID 12250 “Cardiac Ultrasound Common Linear Measurements”
|
|
22
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (241213007, SCT, "Cardiac Shunt Study")
$MeasType = DCID 12217 “Echocardiography Cardiac Shunt”
|
|
23
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5202 “Echo Section”
|
1
|
U
|
|
$SectionSubject = EV (9904008, SCT, "Congenital Anomaly of Cardiovascular System")
$MeasType = DCID 12218 “Echocardiography Congenital”
|
|
24
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5204 “Wall Motion Analysis”
|
1-n
|
U
|
|
$Procedure = DT (35757004, SCT, "Echocardiography for Determining Ventricular Contraction")
|
|
25
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5240 “Myocardial Strain Analysis”
|
1
|
U
|
|
|