DICOM PS3.16 2022a - Content Mapping Resource

CID 6303 Prostate Sector Anatomy from European Concensus 27 Sector (Optimal) Model

Note

From [Prostate Eu Concensus].

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20161106

UID:

1.2.840.10008.6.1.1141

Table CID 6303. Prostate Sector Anatomy from European Concensus 27 Sector (Optimal) Model

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

FMA ID

27 Sector Code

SCT

716925003

Apical anterior fibromuscular stroma of prostate

R0-0001B

C4274179

302546

15as

SCT

716891004

Basal anterior fibromuscular stroma of prostate

R0-00017

C4273850

302539

13as

SCT

716901006

Central zone of left half prostate

R-FFFFC

C4273550

302475

7p

SCT

716900007

Central zone of right half prostate

R-FFFD0

C4274157

302473

1p

SCT

716937001

Left anterior apical peripheral zone of prostate

R0-00025

C4274170

328760

12a

SCT

716905002

Left anterior basal peripheral zone of prostate

R0-00001

C4273857

328753

8a

SCT

716920008

Left anterior middle peripheral zone of prostate

R-FFFB0

C4274185

328768

10a

SCT

716929009

Left apical transition zone of prostate

R-FFFA9

C4274176

328769

11a

SCT

716895008

Left basal part transition zone of prostate

R0-00020

C4274160

328755

7a

SCT

716912006

Left middle transition zone of prostate

R-FFFD5

C4274192

328762

9a

SCT

716939003

Left posterolateral apical peripheral zone of prostate

R-FFFDD

C4274168

328752

12p

SCT

716907005

Left posterolateral basal peripheral zone of prostate

R-FFFC2

C4274197

328759

8p

SCT

716922000

Left posterolateral middle peripheral zone of prostate

R-FFFE9

C4274180

328791

10p

SCT

716941002

Left posteromedial apical peripheral zone of prostate

R0-0000B

C4274166

328792

11p

SCT

716924004

Left posteromedial middle peripheral zone of prostate

R-FFFB5

C4274183

328777

9p

SCT

42320003

Left seminal vesicle

T-93020

C0227980

19388

L SV

SCT

717027004

Male external urethral sphincter

R-FFFD9

C0815353

19733

US

SCT

716908000

Middle anterior fibromuscular stroma of prostate

R-FFFE0

C4274194

302542

14as

SCT

716936005

Right anterior apical peripheral zone of prostate

R0-00003

C4274125

328779

6a

SCT

716904003

Right anterior basal peripheral zone of prostate

R-FFFE2

C4274200

328798

2a

SCT

716919002

Right anterior middle peripheral zone of prostate

R-FFFCD

C4274141

328796

4a

SCT

716928001

Right apical transition zone of prostate

R-FFFC1

C4273855

328773

5a

SCT

716894007

Right basal transition zone of prostate

R-FFFBE

C4274164

328780

1a

SCT

716911004

Right middle transition zone of prostate

R-FFFB6

C4273545

328757

3a

SCT

716938006

Right posterolateral apical peripheral zone of prostate

R-FFFC0

C4273861

328782

6p

SCT

716906001

Right posterolateral basal peripheral zone of prostate

R0-0001E

C4274198

328797

2p

SCT

716921007

Right posterolateral middle peripheral zone of prostate

R0-0000C

C4274184

328771

4p

SCT

716940001

Right posteromedial apical peripheral zone of prostate

R-FFFEA

C4274167

328764

5p

SCT

716923005

Right posteromedial middle peripheral zone of prostate

R-FFFD4

C4274181

328766

3p

SCT

74308000

Right seminal vesicle

T-93010

C0227979

19387

R SV


DICOM PS3.16 2022a - Content Mapping Resource