DICOM PS3.16 2022a - Content Mapping Resource

CID 3687 Electrophysiology Waveform Durations

This Context Group consists of the per-lead terms under the hierarchy of Reference ID MDC_ECG_TIME_PD in the ISO/IEEE 11073-10102 nomenclature.

The base terms from that hierarchy are included in the table below for reference. The per-lead base terms are pre-coordinated with concept discriminators for specific leads, and the code values for those pre-coordinated terms are arithmetically derived from the code values of the base terms. For the complete current list of terms and discriminator values, see the ISO/IEEE Standard. All pre-coordinated terms (measurements plus discriminators) within the identified hierarchy are part of this Context Group.

Note

  1. A prior version of this context group used codes from the SCP-ECG coding system.

  2. Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20110330

UID:

1.2.840.10008.6.1.201

Table CID 3687. Electrophysiology Waveform Durations

Coding Scheme Designator

Code Value

Code Meaning

ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)

MDC

2:6656

P duration, per lead

MDC_ECG_TIME_PD_P

MDC

2:4608

P onset to P1 duration, per lead

MDC_ECG_TIME_PD_P1

MDC

2:4864

P onset to P2 duration, per lead

MDC_ECG_TIME_PD_P2

MDC

2:5120

P onset to P3 duration, per lead

MDC_ECG_TIME_PD_P3

MDC

2:7168

P offset to QRS onset duration, per lead

MDC_ECG_TIME_PD_PR

MDC

2:7680

Q duration, per lead

MDC_ECG_TIME_PD_Q

MDC

2:7936

QRS duration, per lead

MDC_ECG_TIME_PD_QRS

MDC

2:8192

QT duration, per lead

MDC_ECG_TIME_PD_QT

MDC

2:11264

R1 duration, per lead

MDC_ECG_TIME_PD_R_1

MDC

2:11520

R2 duration, per lead

MDC_ECG_TIME_PD_R_2

MDC

2:11776

R3 duration, per lead

MDC_ECG_TIME_PD_R_3

MDC

2:12032

S1 duration, per lead

MDC_ECG_TIME_PD_S_1

MDC

2:12288

S2 duration, per lead

MDC_ECG_TIME_PD_S_2

MDC

2:12544

S3 duration, per lead

MDC_ECG_TIME_PD_S_3

MDC

2:11008

Ventricular activation time, per lead

MDC_ECG_TIME_PD_VENT_ACTIV

MDC

2:32768

PP time period, per lead

MDC_ECG_TIME_PD_PP

MDC

2:33024

RR time period, per lead

MDC_ECG_TIME_PD_RR

MDC

2:33280

PQ time period, per lead

MDC_ECG_TIME_PD_PQ

MDC

2:33536

PQ segment time period, per lead

MDC_ECG_TIME_PD_PQ_SEG

MDC

2:34560

QTU time period, per lead

MDC_ECG_TIME_PD_QTU


DICOM PS3.16 2022a - Content Mapping Resource