LN
|
20168-1
|
Acceleration Time
|
|
C0802983
|
(ms, UCUM, "ms")
|
|
LN
|
59130-5
|
Alias Velocity
|
|
C2923486
|
(m/s, UCUM, "m/s")
|
|
SCT
|
1483009
|
Angle
|
G-A160
|
C0205143
|
(deg, UCUM, "deg"
|
|
SCT
|
42798000
|
Area
|
G-A166
|
C0205146
|
(cm2, UCUM, "cm2")
|
|
SCT
|
75367002
|
Blood Pressure
|
F-31000
|
C0005823
|
(mm[Hg], UCUM, "mmHg")
|
|
SCT
|
70822001
|
Cardiac Ejection Fraction
|
F-32070
|
C0232174
|
(%, UCUM, "%")
|
|
LN
|
20217-6
|
Deceleration Time
|
|
C0803032
|
(ms, UCUM, "ms")
|
|
SCT
|
81827009
|
Diameter
|
M-02550
|
C1301886
|
(cm, UCUM, "cm")
|
|
LN
|
59120-6
|
dP/dt by US
|
|
C2923468
|
(mm[Hg]/s, UCUM, "mmHg/s")
|
|
SCT
|
385673002
|
Interval
|
G-D217
|
C1272706
|
(ms, UCUM, "ms")
|
|
DCM
|
125325
|
Dyssynchrony Index
|
|
|
(ms, UCUM, "ms")
|
|
DCM
|
125326
|
Effective Orifice Area
|
|
|
(cm2, UCUM, "cm2")
|
|
LN
|
59093-5
|
Epicardial Area
|
|
C2923421
|
(cm2, UCUM, "cm2")
|
|
DCM
|
125327
|
Excursion Distance
|
|
|
(cm, UCUM, "cm")
|
|
LN
|
59132-1
|
Fractional Shortening
|
|
C2923490
|
(%, UCUM, "%")
|
|
SCT
|
410668003
|
Length
|
G-D7FE
|
C1444754
|
(cm, UCUM, "cm")
|
|
SCT
|
118538004
|
Mass
|
G-D701
|
C1306372
|
(g, UCUM, "g")
|
|
DCM
|
125328
|
Maximum Orifice Area
|
|
|
(cm2, UCUM, "cm2")
|
|
SCT
|
6797001
|
Mean Blood Pressure
|
F-31150
|
C0428886
|
(mm[Hg], UCUM, "mmHg")
|
|
LN
|
20256-4
|
Mean Gradient [Pressure] by Doppler
|
|
C0803071
|
(mm[Hg], UCUM, "mmHg")
|
|
LN
|
20352-1
|
Mean Blood Velocity
|
|
C0803167
|
(m/s, UCUM, "m/s")
|
|
SCT
|
131188004
|
Minor Axis
|
G-A194
|
C1295724
|
(cm, UCUM, "cm")
|
|
LN
|
59099-2
|
Myocardial Performance Index (Tei)
|
|
C2923433
|
(1, UCUM, "no units")
|
|
LN
|
20247-3
|
Peak Gradient [Pressure]
|
|
C0803062
|
(mm[Hg], UCUM, "mmHg")
|
|
LN
|
34141-2
|
Peak Instantaneous Flow Rate
|
|
C1316604
|
(ml/s, UCUM, "ml/s")
|
|
DCM
|
125329
|
Peak Blood Pressure
|
|
|
(mm[Hg], UCUM, "mmHg")
|
|
LN
|
11726-7
|
Peak Systolic Blood Velocity
|
|
C0551845
|
(m/s, UCUM, "m/s")
|
|
DCM
|
125330
|
Peak Tissue Velocity
|
|
|
(cm/s, UCUM, "cm/s")
|
|
DCM
|
125331
|
PISA Radius
|
|
|
(cm, UCUM, "cm")
|
|
LN
|
20280-4
|
Pressure Half Time
|
|
C0803095
|
(ms, UCUM, "ms")
|
|
SCT
|
399301000
|
Regurgitant Fraction
|
G-0390
|
C1302309
|
(%, UCUM, "%")
|
|
DCM
|
125332
|
Regurgitation Jet Area
|
|
|
(cm2, UCUM, "cm2")
|
|
DCM
|
125333
|
Regurgitation Jet Width
|
|
|
(cm, UCUM, "cm")
|
|
LN
|
59090-1
|
Internal Dimension
|
|
C2923417
|
(cm, UCUM, "cm")
|
|
LN
|
59089-3
|
Thickness
|
|
C2923416
|
(cm, UCUM, "cm")
|
|
SCT
|
90096001
|
Stroke Volume
|
F-32120
|
C0038455
|
(ml, UCUM, "ml")
|
|
SCT
|
251271006
|
Vascular Resistance
|
F-02692
|
C0429119
|
(dyn.s/cm5, UCUM, "dyn.s/cm5")
|
|
LN
|
20354-7
|
Velocity Time Integral
|
|
C0803169
|
(cm, UCUM, "cm")
|
|
DCM
|
125334
|
Vena Contracta Width
|
|
|
(cm, UCUM, "cm")
|
|
SCT
|
118565006
|
Volume
|
G-D705
|
C0449468
|
(ml, UCUM, "ml")
|
|
LN
|
33878-0
|
Volume Flow Rate
|
|
C1316341
|
(ml/s, UCUM, "ml/s")
|
|
Include CID 12311 “Echo Measured Strain Properties”
|