DICOM PS3.16 2022a - Content Mapping Resource

CID 12300 Core Echo Measurements

This codeset is populated mostly based on measurements identified in best practice articles published by the American Society of Echocardiography (ASE). The LOINC codes were introduced after fully modelling the underlying semantics of the measurement. The Units column contains the proper UCUM representation of the recommended units for the measured property.

Note

The Code Meaning shown here reflects the colloquial style by which the measurements were identified in the ASE articles and would likely be appropriate for displaying to users. However, implementers of clinical applications and databases will need to review the definitions of these measurements to correctly understand the full pre-coordinated semantics of the codes. Similarly, reuse of the codes based on the Code Meaning text without reviewing and confirming the applicability of the full semantics found in the code definitions is discouraged.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Non-Extensible

Version:

20211112

UID:

1.2.840.10008.6.1.1149

Table CID 12300. Core Echo Measurements

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

Units

LN

79940-3

Aortic annulus diameter

C4070180

(cm, UCUM, "cm")

LN

79941-1

Aortic regurgitant flow

C4071396

(ml/s, UCUM, "ml/s")

LN

79942-9

Aortic regurgitant fraction

C4071395

(%, UCUM, "%")

LN

79943-7

Aortic regurgitant jet area/LVOT area %

C4069758

(%, UCUM, "%")

LN

79944-5

Aortic regurgitant jet width/LVOT width %

C4069757

(%, UCUM, "%")

LN

79945-2

Aortic regurgitation PISA radius

C4069756

(cm, UCUM, "cm")

LN

79946-0

Aortic regurgitation PISA velocity

C4069755

(cm/s, UCUM, "cm/s")

LN

79947-8

Aortic regurgitation pressure half-time

C4069754

(ms, UCUM, "ms")

LN

79948-6

Aortic regurgitation vena contracta width

C4069753

(cm, UCUM, "cm")

LN

79949-4

Aortic regurgitation Vmax

C4069752

(cm/s, UCUM, "cm/s")

LN

79950-2

Aortic regurgitation volume (Continuity VTI)

C4070676

(ml, UCUM, "ml")

LN

79951-0

Aortic regurgitation volume (PISA)

C4070675

(ml, UCUM, "ml")

LN

79952-8

Aortic regurgitation VTI

C4070674

(cm, UCUM, "cm")

LN

79953-6

Aortic root diameter

C4070673

(cm, UCUM, "cm")

LN

79954-4

Aortic root diameter / BSA

C4069751

(cm/m2, UCUM, "cm/m2")

LN

79955-1

Aortic sinotubular junction dimension

C4069750

(cm, UCUM, "cm")

LN

79956-9

Aortic valve area (Continuity Vmax)

C4069749

(cm2, UCUM, "cm2")

LN

79957-7

Aortic valve area (Continuity Vmax) / BSA

C4069748

(cm2/m2, UCUM, "cm2/m2")

LN

79958-5

Aortic valve area (Continuity VTI)

C4069747

(cm2, UCUM, "cm2")

LN

79959-3

Aortic valve area (Continuity VTI) / BSA

C4069746

(cm2/m2, UCUM, "cm2/m2")

LN

79960-1

Aortic valve effective regurgitant orifice area

C4069745

(cm2, UCUM, "cm2")

LN

79961-9

Aortic valve mean blood velocity

C4069744

(cm/s, UCUM, "cm/s")

LN

79962-7

Aortic valve mean gradient

C4050483

(mm[Hg], UCUM, "mmHg")

LN

79963-5

Aortic valve peak instantaneous gradient

C4050482

(mm[Hg], UCUM, "mmHg")

LN

79964-3

Aortic valve Vmax

C4069743

(cm/s, UCUM, "cm/s")

LN

79965-0

Aortic valve VTI

C4069742

(cm, UCUM, "cm")

LN

79966-8

Ascending Aorta Dimension

C4069741

(cm, UCUM, "cm")

LN

79967-6

Inferior vena cava diameter

C4069740

(cm, UCUM, "cm")

LN

79968-4

Interventricular septum diastolic dimension MM

C4069739

(cm, UCUM, "cm")

LN

79969-2

Interventricular septum diastolic dimension 2D

C4069738

(cm, UCUM, "cm")

LN

79970-0

Interventricular septum systolic dimension MM

C4069737

(cm, UCUM, "cm")

LN

79971-8

Interventricular septum systolic dimension 2D

C4069736

(cm, UCUM, "cm")

LN

79972-6

Interventricular septum time to peak displacement

C4069735

(ms, UCUM, "ms")

LN

79973-4

Left atrial end systolic area 2C

C4069734

(cm2, UCUM, "cm2")

LN

79974-2

Left atrial end systolic area 4C

C4069733

(cm2, UCUM, "cm2")

LN

79975-9

Left atrial end systolic diameter (AP) 2D

C4069732

(cm, UCUM, "cm")

LN

79976-7

Left atrial end systolic diameter (AP) 2D / BSA

C4069731

(cm/m2, UCUM, "cm/m2")

LN

79977-5

Left atrial end systolic diameter (AP) MM

C4069730

(cm, UCUM, "cm")

LN

79978-3

Left atrial end systolic diameter (AP) MM / BSA

C4069729

(cm/m2, UCUM, "cm/m2")

LN

79979-1

Left atrial end systolic length 2C

C4069728

(cm, UCUM, "cm")

LN

79980-9

Left atrial end systolic length 4C

C4069727

(cm, UCUM, "cm")

LN

79981-7

Left atrial end systolic volume biplane (area-length)

C4069726

(ml, UCUM, "ml")

LN

79982-5

Left atrial end systolic volume biplane (area-length) / BSA

C4069725

(ml/m2, UCUM, "ml/m2")

LN

79983-3

Left atrial end systolic volume biplane (MOD)

C4069724

(ml, UCUM, "ml")

LN

79984-1

Left atrial end systolic volume biplane (MOD) / BSA

C4069723

(ml/m2, UCUM, "ml/m2")

LN

79985-8

Left atrial end systolic volume single plane 2C (MOD)

C4069722

(ml, UCUM, "ml")

LN

79986-6

Left atrial end systolic volume single plane 4C (MOD)

C4069721

(ml, UCUM, "ml")

LN

79987-4

Left pulmonary artery diameter

C4069720

(cm, UCUM, "cm")

LN

79988-2

Left venticular posterior wall time to peak displacement

C4069719

(ms, UCUM, "ms")

LN

79989-0

Left ventricular pre-ejection period

C4050481

(ms, UCUM, "ms")

LN

77891-0

Left ventricular ejection fraction (Teichholz) 2D

C4036567

(%, UCUM, "%")

LN

18049-7

Left ventricular ejection fraction (Teichholz) MM

C0801098

(%, UCUM, "%")

LN

79990-8

Left ventricular ejection fraction 3D

C4069718

(%, UCUM, "%")

LN

79991-6

Left ventricular ejection fraction biplane (MOD)

C4069717

(%, UCUM, "%")

LN

79992-4

Left ventricular ejection fraction single plane 2C (MOD)

C4069716

(%, UCUM, "%")

LN

79993-2

Left ventricular ejection fraction single plane 4C (MOD)

C4069715

(%, UCUM, "%")

LN

79994-0

Left ventricular end diastolic length 4C

C4069714

(cm, UCUM, "cm")

LN

79995-7

Left ventricular end diastolic volume (3D)

C4069713

(ml, UCUM, "ml")

LN

79996-5

Left ventricular end diastolic volume biplane (MOD)

C4069712

(ml, UCUM, "ml")

LN

79997-3

Left ventricular end diastolic volume biplane (MOD) / BSA

C4069711

(ml/m2, UCUM, "ml/m2")

LN

79998-1

Left ventricular end diastolic volume single plane 2C (MOD)

C4069710

(ml, UCUM, "ml")

LN

79999-9

Left ventricular end diastolic volume single plane 4C (MOD)

C4069700

(ml, UCUM, "ml")

LN

80000-3

Left ventricular end systolic volume (3D)

C4069699

(ml, UCUM, "ml")

LN

80001-1

Left ventricular end systolic volume biplane (MOD)

C4069698

(ml, UCUM, "ml")

LN

80002-9

Left ventricular end systolic volume biplane (MOD) / BSA

C4069697

(ml/m2, UCUM, "ml/m2")

LN

80003-7

Left ventricular end systolic volume single plane 2C (MOD)

C4069696

(ml, UCUM, "ml")

LN

80004-5

Left ventricular end systolic volume single plane 4C (MOD)

C4069695

(ml, UCUM, "ml")

LN

80005-2

Left ventricular endocardial area SAX PM level

C4069694

(cm2, UCUM, "cm2")

LN

80006-0

Left ventricular epicardial area SAX PM level

C4069693

(cm2, UCUM, "cm2")

LN

29434-8

Left ventricular fractional shortening (of minor axis) (2D)

C0945750

(%, UCUM, "%")

LN

29435-5

Left ventricular fractional shortening (of minor axis) (MM)

C0944886

(%, UCUM, "%")

LN

80007-8

Left ventricular internal diastolic dimension - 2D

C4069692

(cm, UCUM, "cm")

LN

80008-6

Left ventricular internal diastolic dimension - MM

C4069691

(cm, UCUM, "cm")

LN

80009-4

Left ventricular internal diastolic dimension / BSA

C4069690

(cm/m2, UCUM, "cm/m2")

LN

80010-2

Left ventricular internal diastolic dimension / BSA

C4069689

(cm/m2, UCUM, "cm/m2")

LN

80011-0

Left ventricular internal systolic dimension - 2D

C4069688

(cm, UCUM, "cm")

LN

80012-8

Left ventricular internal systolic dimension - MM

C4069687

(cm, UCUM, "cm")

LN

80013-6

Left ventricular internal systolic dimension / BSA

C4069686

(cm/m2, UCUM, "cm/m2")

LN

80014-4

Left ventricular internal systolic dimension / BSA

C4069685

(cm/m2, UCUM, "cm/m2")

LN

18071-1

Left ventricular isovolumic relaxation time by Doppler

C0801120

(ms, UCUM, "ms")

LN

80015-1

Left ventricular isovolumic relaxation time by TDI

C4069684

(ms, UCUM, "ms")

LN

80016-9

Left ventricular mass (area-length)

C4069683

(g, UCUM, "g")

LN

80017-7

Left ventricular mass (area-length) / BSA

C4069682

(g/m2, UCUM, "g/m2")

LN

80018-5

Left ventricular mass (area-length) / height^^2.7

C4069681

(g/m2.7, UCUM, "g/m2.7")

LN

80019-3

Left ventricular mass (dimension method) 2D

C4069680

(g, UCUM, "g")

LN

80020-1

Left ventricular mass (dimension method) 2D / BSA

C4069679

(g/m2, UCUM, "g/m2")

LN

80021-9

Left ventricular mass (dimension method) 2D / height^^2.7

C4069678

(g/m2.7, UCUM, "g/m2.7")

LN

80022-7

Left ventricular mass (dimension method) MM

C4266236

(g, UCUM, "g")

LN

80023-5

Left ventricular mass (dimension method) MM / BSA

C4069671

(g/m2, UCUM, "g/m2")

LN

80024-3

Left ventricular mass (dimension method) MM / height^^2.7

C4069670

(g/m2.7, UCUM, "g/m2.7")

LN

80025-0

Left ventricular mass (truncated ellipse)

C4069669

(g, UCUM, "g")

LN

80026-8

Left ventricular mass (truncated ellipse) / BSA

C4069668

(g/m2, UCUM, "g/m2")

LN

80027-6

Left ventricular mass (truncated ellipse) / height^^2.7

C4069667

(g/m2.7, UCUM, "g/m2.7")

LN

80028-4

Left ventricular outflow tract dimension (2D)

C4069666

(cm, UCUM, "cm")

LN

80029-2

Left ventricular outflow tract Vmax

C4069665

(cm/s, UCUM, "cm/s")

LN

80030-0

Left ventricular outflow tract VTI

C4069664

(cm, UCUM, "cm")

LN

80031-8

Left ventricular posterior wall diastolic thickness

C4069663

(cm, UCUM, "cm")

LN

80032-6

Left ventricular posterior wall diastolic thickness

C4069662

(cm, UCUM, "cm")

LN

80033-4

Left ventricular posterior wall systolic thickness

C4069661

(cm, UCUM, "cm")

LN

80034-2

Left ventricular posterior wall systolic thickness

C4069660

(cm, UCUM, "cm")

LN

80035-9

Left ventricular stroke volume 3D

C4069659

(ml, UCUM, "ml")

LN

80036-7

LV basal anterior time to S Vmax (Ts-basal anterior)

C4069658

(ms, UCUM, "ms")

LN

80037-5

LV basal anteroseptal time to S Vmax (TS-basal anteroseptal)

C4069657

(ms, UCUM, "ms")

LN

80038-3

LV basal inferior time to S Vmax (Ts-basal inferior)

C4069656

(ms, UCUM, "ms")

LN

80039-1

LV basal lateral time to S Vmax (Ts-basal lateral)

C4069655

(ms, UCUM, "ms")

LN

80040-9

LV basal posterior time to S Vmax (Ts-basal posterior)

C4069654

(ms, UCUM, "ms")

LN

80041-7

LV basal septal time to S Vmax (Ts-basal septal)

C4069653

(ms, UCUM, "ms")

LN

80042-5

LV mid anterior time to S Vmax (Ts-mid anterior)

C4069652

(ms, UCUM, "ms")

LN

80043-3

LV mid anteroseptal time to S Vmax (Ts-mid anteroseptal)

C4069651

(ms, UCUM, "ms")

LN

80044-1

LV mid inferior time to S Vmax (Ts-mid inferior)

C4069650

(ms, UCUM, "ms")

LN

80045-8

LV mid lateral time to S Vmax (Ts-mid lateral)

C4069649

(ms, UCUM, "ms")

LN

80046-6

LV mid posterior time to S Vmax (Ts-mid posterior)

C4069648

(ms, UCUM, "ms")

LN

80047-4

LV mid septal time to S Vmax (Ts-mid septal)

C4069647

(ms, UCUM, "ms")

LN

80048-2

LV Ts-SD (Dyssynchrony Index)

C4069646

(ms, UCUM, "ms")

LN

80049-0

Main pulmonary artery diameter

C4069645

(cm, UCUM, "cm")

LN

Main pulmonary artery Vmax

(cm/s, UCUM, "cm/s")

LN

80050-8

Mitral annulus diastolic diameter - A2C

C4069644

(cm, UCUM, "cm")

LN

80051-6

Mitral annulus diastolic diameter - A4C

C4069643

(cm, UCUM, "cm")

LN

80052-4

Mitral annulus diastolic diameter - PLAX

C4069642

(cm, UCUM, "cm")

LN

80053-2

Mitral annulus VTI

C4069641

(cm, UCUM, "cm")

LN

80054-0

Mitral lateral e-prime Vmax

C4069640

(cm/s, UCUM, "cm/s")

LN

80057-3

Mitral regurgitant flow (PISA)

C4069637

(ml/s, UCUM, "ml/s")

LN

80055-7

Mitral regurgitant fraction (Continuity VTI)

C4069639

(%, UCUM, "%")

LN

80056-5

Mitral regurgitant fraction (PISA)

C4069638

(%, UCUM, "%")

LN

80058-1

Mitral regurgitation peak gradient

C4069636

(mm[Hg], UCUM, "mmHg")

LN

80059-9

Mitral regurgitation PISA radius

C4069635

(cm, UCUM, "cm")

LN

80060-7

Mitral regurgitation PISA velocity

C4069634

(cm/s, UCUM, "cm/s")

LN

80061-5

Mitral regurgitation vena contracta width

C4069633

(cm, UCUM, "cm")

LN

80062-3

Mitral regurgitation Vmax

C4069632

(cm/s, UCUM, "cm/s")

LN

80063-1

Mitral regurgitation volume (Continuity VTI)

C4069631

(ml, UCUM, "ml")

LN

80064-9

Mitral regurgitation volume (PISA)

C4069630

(ml, UCUM, "ml")

LN

79911-4

Mitral septal e-prime Vmax

C4069780

(cm/s, UCUM, "cm/s")

LN

80067-2

Mitral valve area (PISA)

C4069709

(cm2, UCUM, "cm2")

LN

80068-0

Mitral valve area (Planimetry)

C4069708

(cm2, UCUM, "cm2")

LN

80069-8

Mitral valve area (Pressure Half-Time)

C4069707

(cm2, UCUM, "cm2")

LN

80065-6

Mitral valve A-wave duration

C4069629

(ms, UCUM, "ms")

LN

80066-4

Mitral valve A-wave Vmax

C4069628

(cm/s, UCUM, "cm/s")

LN

78191-4

Mitral valve deceleration time

C4071233

(ms, UCUM, "ms")

LN

80071-4

Mitral valve effective regurgitant orifice area (PISA)

C4069627

(cm2, UCUM, "cm2")

LN

18038-0

Mitral valve E-to-A ratio

C0801087

(1, UCUM, "no units")

LN

80070-6

Mitral valve E-wave Vmax

C4069706

(cm/s, UCUM, "cm/s")

LN

80072-2

Mitral valve flow propagation velocity (Vp)

C4069626

(cm/s, UCUM, "cm/s")

LN

80073-0

Mitral valve mean gradient

C4069625

(mm[Hg], UCUM, "mmHg")

LN

80074-8

Mitral valve peak instantaneous gradient

C4069624

(mm[Hg], UCUM, "mmHg")

LN

79912-2

Mitral valve pressure half-time

C4069779

(ms, UCUM, "ms")

LN

79913-0

Mitral valve Vmax

C4069778

(cm/s, UCUM, "cm/s")

LN

79914-8

Mitral valve VTI

C4069777

(cm, UCUM, "cm")

LN

78184-9

Pulmonary vein A-wave duration

C4071240

(ms, UCUM, "ms")

LN

79915-5

Pulmonary vein A-wave Vmax

C4069776

(cm/s, UCUM, "cm/s")

LN

79916-3

Pulmonary vein D-wave Vmax

C4069775

(cm/s, UCUM, "cm/s")

LN

79917-1

Pulmonary vein S-wave Vmax

C4069774

(cm/s, UCUM, "cm/s")

LN

79909-8

Pulmonic annulus diameter

C4069782

(cm, UCUM, "cm")

LN

79934-6

Pulmonic regurgitation end diastolic peak gradient

C4071399

(mm[Hg], UCUM, "mmHg")

LN

79918-9

Pulmonic regurgitation end diastolic velocity

C4069773

(cm/s, UCUM, "cm/s")

LN

79919-7

Pulmonic regurgitation Vmax

C4069772

(cm/s, UCUM, "cm/s")

LN

79928-8

Pulmonic valve acceleration time

C4069763

(ms, UCUM, "ms")

LN

18042-2

Pulmonic valve ejection time

C0801091

(ms, UCUM, "ms")

LN

79935-3

Pulmonic valve peak gradient

C4071398

(mm[Hg], UCUM, "mmHg")

LN

79920-5

Pulmonic valve Vmax

C4069771

(cm/s, UCUM, "cm/s")

LN

79910-6

Pulmonic valve VTI

C4069781

(cm, UCUM, "cm")

LN

80075-5

Right atrial end systolic area 4C

C4069623

(cm2, UCUM, "cm2")

LN

80076-3

Right atrial major axis dimension 4C

C4069622

(cm, UCUM, "cm")

LN

80077-1

Right atrial minor axis dimension 4C

C4069621

(cm, UCUM, "cm")

LN

80078-9

Right atrial minor axis dimension 4C / BSA

C4069620

(cm/m2, UCUM, "cm/m2")

LN

80079-7

Right pulmonary artery diameter

C4069619

(cm, UCUM, "cm")

LN

80080-5

Right ventricular basal dimension 4C

C4069618

(cm, UCUM, "cm")

LN

79929-6

Right ventricular ejection time

C4069762

(ms, UCUM, "ms")

LN

80081-3

Right ventricular end diastolic area 4C

C4069617

(cm2, UCUM, "cm2")

LN

80082-1

Right ventricular end systolic area 4C

C4069616

(cm2, UCUM, "cm2")

LN

79936-1

Right ventricular fractional area change

C4071397

(%, UCUM, "%")

LN

80083-9

Right ventricular free wall thickness 2D

C4069615

(cm, UCUM, "cm")

LN

80084-7

Right ventricular free wall thickness MM

C4069614

(cm, UCUM, "cm")

LN

80085-4

Right ventricular mid-cavity dimension 4C

C4069613

(cm, UCUM, "cm")

LN

80086-2

Right ventricular myocardial performance index

C4069612

(1, UCUM, "no units")

LN

80087-0

Right ventricular outflow tract diameter at pulmonic valve (RVOT-Distal)

C4069611

(cm, UCUM, "cm")

LN

80088-8

Right ventricular outflow tract diameter at subvalvular level (RVOT-Proximal)

C4069610

(cm, UCUM, "cm")

LN

80089-6

Right ventricular outflow tract VTI

C4069609

(cm, UCUM, "cm")

LN

80090-4

Right ventricular pre-ejection period

C4069608

(ms, UCUM, "ms")

LN

77903-3

Tricuspid Annular Plane Systolic Excursion (TAPSE)

C4036560

(cm, UCUM, "cm")

LN

80091-2

Tricuspid annulus diameter

C4069607

(cm, UCUM, "cm")

LN

79937-9

Tricuspid regurgitation peak gradient

C4070183

(mm[Hg], UCUM, "mmHg")

LN

79932-0

Tricuspid regurgitation PISA radius

C4069759

(cm, UCUM, "cm")

LN

79933-8

Tricuspid regurgitation vena contracta width

C4071400

(cm, UCUM, "cm")

LN

79921-3

Tricuspid regurgitation Vmax

C4069770

(cm/s, UCUM, "cm/s")

LN

79922-1

Tricuspid valve a-prime Vmax

C4069769

(cm/s, UCUM, "cm/s")

LN

79923-9

Tricuspid valve A-wave Vmax

C4069768

(cm/s, UCUM, "cm/s")

LN

79930-4

Tricuspid valve closure to opening time

C4069761

(ms, UCUM, "ms")

LN

79931-2

Tricuspid valve deceleration time

C4069760

(ms, UCUM, "ms")

LN

18175-0

Tricuspid valve diastolic VTI

C0801224

(cm, UCUM, "cm")

LN

79924-7

Tricuspid valve e-prime Vmax

C4069767

(cm/s, UCUM, "cm/s")

LN

79925-4

Tricuspid valve E-wave Vmax

C4069766

(cm/s, UCUM, "cm/s")

LN

79938-7

Tricuspid valve mean gradient

C4070182

(mm[Hg], UCUM, "mmHg")

LN

79939-5

Tricuspid valve peak gradient

C4070181

(mm[Hg], UCUM, "mmHg")

LN

18032-3

Tricuspid valve pressure half-time

C0801081

(ms, UCUM, "ms")

LN

79926-2

Tricuspid valve s-prime Vmax

C4069765

(cm/s, UCUM, "cm/s")

LN

79927-0

Tricuspid valve Vmax

C4069764

(cm/s, UCUM, "cm/s")

Include CID 12309 “Core Echo Strain Measurements”


DICOM PS3.16 2022a - Content Mapping Resource