DICOM PS3.16 2022a - Content Mapping Resource

CID 12226 Echocardiography Image View

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20211112

UID:

1.2.840.10008.6.1.617

Table CID 12226. Echocardiography Image View

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

399232001

Apical two chamber

G-A19B

C1302267

SCT

399214001

Apical four chamber

G-A19C

C1302256

DCM

130681

Apical four chamber RV Focused

DCM

130682

Apical four chamber RV Modified

SCT

399339008

Apical long axis

G-0395

C1302329

SCT

399139001

Parasternal long axis

G-0396

C1302222

SCT

443082005

Parasternal long axis view of the RV inflow tract

G-0577

C2733536

SCT

443083000

Parasternal long axis view of the RV outflow tract

G-0578

C2733537

SCT

399306005

Parasternal short axis

G-0397

C1302312

SCT

399239005

Parasternal short axis at the aortic valve level

G-0398

C1302271

SCT

399371001

Parasternal short axis at the level of the mitral chords

G-0399

C1302348

SCT

399036006

Parasternal short axis at the Mitral Valve level

G-039A

C1302178

SCT

399271003

Parasternal short axis at the Papillary Muscle level

G-039B

C1302289

SCT

398998003

Right Ventricular Inflow Tract View

G-039C

C1275800

SCT

399195005

Right Ventricular Outflow Tract View

G-039D

C1275831

SCT

399310008

Subcostal long axis

G-039E

C1302316

SCT

399200001

Subcostal short axis

G-039F

C1302251

SCT

399106004

Suprasternal long axis

G-03A0

C1302206

SCT

399145009

Suprasternal short axis

G-03A1

C1302224

SCT

443698002

Transesophageal short axis view

R-40B0E

C2733008

SCT

443100003

Subcostal view of cardiac outlets directed anteriorly

R-40AFF

C2732944

SCT

443160001

Subcostal short axis view at papillary muscle level

G-0579

C2732745

SCT

443499004

Subcostal short axis view at mitral valve level

G-057B

C2732947

SCT

443609003

Subcostal short axis view at aortic valve level

G-057E

C2733524

SCT

443500008

Subcostal short axis view at venous inflow level

G-057C

C2733525

SCT

443640005

Subcostal oblique coronal view

R-40B0A

C2733526

SCT

443162009

Suprasternal coronal view

R-40B00

C2733098

SCT

443163004

Suprasternal sagittal view

R-40B01

C2733099

SCT

443562002

Suprasternal long axis view of aortic arch

G-057D

C2732456


DICOM PS3.16 2022a - Content Mapping Resource