DICOM PS3.16 2022a - Content Mapping Resource

N Externally Defined Value Sets (Informative)

This annex identifies those Value Sets defined externally to the DICOM Standard that are referenced by the Standard. These value sets are reproduced here for reference only, and might not be the current version.

These value sets use codes from various coding schemes or code systems, as identified in Section 8.

N.1 HL7 Value Sets

HL7 Value Sets are reproduced with the permission of HL7 International. For the current version of HL7 Value Sets, see the HL7v3 Normative Edition (http://www.hl7.org/implement/standards/product_brief.cfm?product_id=186).

Table N.1-1. HL7 Value Sets

Value Set Name

OID

Notes

ActPriority

2.16.840.1.113883.11.16866

AdministrativeGender

2.16.840.1.113883.11.1

HumanLanguages

2.16.840.1.113883.11.11526

Equivalent to CID 5000

ImageMediaType

2.16.840.1.113883.11.14839

NullFlavor

2.16.840.1.113883.11.10609

ObservationInterpretation

2.16.840.1.113883.11.78

x_BasicConfidentialityKind

2.16.840.1.113883.11.16926

x_serviceEventPerformer

2.16.840.1.113883.11.19601


N.1.1 ActPriority Value Set

Value Set:

ActPriority 2.16.840.1.113883.11.16866

Code System(s):

ActPriority 2.16.840.1.113883.5.7

Table N.1.1-1. ActPriority Value Set

Code

Code System

Print Name

A

ActPriority

ASAP

CR

ActPriority

Callback results

CS

ActPriority

Callback for scheduling

CSP

ActPriority

Callback placer for scheduling

CSR

ActPriority

Contact recipient for scheduling

EL

ActPriority

Elective

EM

ActPriority

Emergency

P

ActPriority

Preoperative

PRN

ActPriority

As needed

R

ActPriority

Routine

RR

ActPriority

Rush reporting

S

ActPriority

Stat

T

ActPriority

Timing critical

UD

ActPriority

Use as directed

UR

ActPriority

Urgent


N.1.2 AdministrativeGender Value Set

Value Set:

AdministrativeGender 2.16.840.1.113883.11.1

Code System(s):

AdministrativeGender 2.16.840.1.113883.5.1

Table N.1.2-1. AdministrativeGender Value Set

Code

Code System

Print Name

F

AdministrativeGender

Female

M

AdministrativeGender

Male

UN

AdministrativeGender

Undifferentiated


N.1.3 ImageMediaType Value Set

Value Set:

HL7 ImageMediaType 2.16.840.1.113883.11.14839

Code System(s):

mediaType 2.16.840.1.113883.5.79

Table N.1.3-1. ImageMediaType Value Set

Code

Code System

Print Name

image/g3fax

mediaType

g3fax

image/gif

mediaType

gif

image/jpeg

mediaType

jpeg

image/png

mediaType

png

image/tiff

mediaType

tiff


N.1.4 NullFlavor Value Set

Value Set:

HL7 NullFlavor 2.16.840.1.113883.11.10609

Code System(s):

NullFlavor 2.16.840.1.113883.5.1008

Table N.1.4-1. NullFlavor Value Set

Code

Code System

Print Name

NI

NullFlavor

No Information

OTH

NullFlavor

other

NINF

NullFlavor

negative infinity

PINF

NullFlavor

positive infinity

UNK

NullFlavor

unknown

ASKU

NullFlavor

asked but unknown

NAV

NullFlavor

temporarily unavailable

NASK

NullFlavor

not asked

TRC

NullFlavor

trace

MSK

NullFlavor

masked

NA

NullFlavor

not applicable

NP

NullFlavor

not present


N.1.5 ObservationInterpretation Value Set

Value Set:

HL7 ObservationInterpretation 2.16.840.1.113883.11.78

Code System(s):

ObservationInterpretation 2.16.840.1.113883.5.83

Table N.1.5-1. ObservationInterpretation Value Set

Code

Code System

Print Name

B

ObservationInterpretation

better

D

ObservationInterpretation

decreased

U

ObservationInterpretation

increased

W

ObservationInterpretation

worse

<

ObservationInterpretation

low off scale

>

ObservationInterpretation

high off scale

A

ObservationInterpretation

Abnormal

AA

ObservationInterpretation

Abnormal alert

HH

ObservationInterpretation

High alert

LL

ObservationInterpretation

Low alert

H

ObservationInterpretation

High

L

ObservationInterpretation

Low

N

ObservationInterpretation

Normal

I

ObservationInterpretation

intermediate

MS

ObservationInterpretation

moderately susceptible

R

ObservationInterpretation

resistent

S

ObservationInterpretation

susceptible

VS

ObservationInterpretation

very susceptible


N.1.6 x_BasicConfidentialityKind Value Set

Value Set:

x_BasicConfidentialityKind 2.16.840.1.113883.11.16926

Code System(s):

Confidentiality 2.16.840.1.113883.5.25

Table N.1.6-1. x_BasicConfidentialityKind Value Set

Code

Code System

Print Name

N

Confidentiality

Normal

R

Confidentiality

Restricted

V

Confidentiality

Very Restricted


N.1.7 x_serviceEventPerformer Value Set

Value Set:

HL7 x_serviceEventPerformer 2.16.840.1.113883.11.19601

Code System(s):

ParticipationType 2.16.840.1.113883.5.90

Table N.1.7-1. x_serviceEventPerformer Value Set

Code

Code System

Print Name

PRF

ParticipationType

Performer

PPRF

ParticipationType

Principal performer

SPRF

ParticipationType

Secondary performer


DICOM PS3.16 2022a - Content Mapping Resource