DICOM PS3.16 2022a - Content Mapping Resource

H Code Meanings of LOINC Codes in DCMR

Code Meanings for LOINC codes may use the LOINC "Long Common Name" for the Code Meaning, or if that is too long for the Value Representation of Code Meaning, or if it is preferred, the LOINC "Short Name" (which will be less than 40 characters), or synonyms as specified in this Annex.

Table H-1. Code Meanings of LOINC Codes

Code Value

Code Meaning

10160-0

History of Medication Use

11329-0

History

11450-4

Problem List

42148-7

Echocardiography Report

11525-3

Ultrasound Obstetric and Gyn Report

11528-7

Radiology Report

24627-2

CT Chest Report

24725-4

CT Head Report

41806-1

CT Abdomen Report

24590-2

MRI Head Report

11612-9

Aborta

11623-6

Fourth Quadrant Diameter

11624-4

First Quadrant Diameter

11625-1

Third Quadrant Diameter

11626-9

Second Quadrant Diameter

11629-3

Outer Orbital Diameter

11636-8

Live Births

11653-3

End Diastolic Velocity

11665-7

Minimum Diastolic Velocity

11692-1

Time averaged peak velocity

11726-7

Peak Systolic Blood Velocity

11726-7

Peak Velocity

11727-5

Estimated Weight

11732-5

EFW by AC, BPD, FL, HC, Hadlock 1985

11734-1

EFW by AC, BPD, FL, Hadlock 1984

11735-8

EFW by AC, BPD, FL, Hadlock 1985

11738-2

EFW by AC, BPD, Hadlock 1984

11739-0

EFW by AC and BPD, Shepard 1982

11746-5

EFW by AC, FL, HC, Hadlock 1985

11750-7

EFW by AC, FL, Hadlock 1984

11751-5

EFW by AC, FL, Hadlcok 1985

11754-9

EFW by AC, HC Hadlock 1984

11756-4

EFW by AC, Campbell 1975

11767-1

EFW percentile rank

11778-8

Estimated Date of Delivery

11779-6

EDD from LMP

11780-4

EDD from ovulation date

11781-2

EDD from average ultrasound age

11793-7

Follicle Diameter

11816-6

Yolk Sac length

11818-2

Anterior-Posterior Abdominal Diameter

11819-0

Anterior-Posterior Trunk Diameter

11820-8

Biparietal Diameter

11823-2

Cephalic Index

11824-0

BPD area corrected

11825-7

Left Kidney width

11827-3

Right Kidney width

11829-9

Left Ovary Width

11830-7

Right Ovary Width

11834-9

Left Kidney length

11836-4

Right Kidney length

11840-6

Left Ovary Length

11841-4

Right Ovary Length

11850-5

Gestational Sac Diameter

11851-3

Occipital-Frontal Diameter

11853-9

Left Kidney thickness

11855-4

Right Kidney thickness

11857-0

Left Ovary Height

11858-8

Right Ovary Height

11860-4

Cisterna Magna Length

11862-0

Transverse Abdominal Diameter

11863-8

Transverse Cerebellar Diameter

11864-6

Transverse Thoracic Diameter

11871-1

FL/AC

11872-9

FL/BPD

11873-7

FL/HC

11878-6

Number of Fetuses by US

11884-4

Average Ultrasound Age

11885-1

Gestational Age by LMP

11886-9

Gestational Age by ovulation date

11888-5

Composite Ultrasound Age

11889-3

AC, Campbell 1975

11892-7

AC, Hadlock 1984

11893-5

AC, Jeanty 1984

11900-8

BPD, Doubilet 1993

11901-6

BPDa, Hadlock 1982

11902-4

BPD, Hadlock 1984

11903-2

BPD, Hansmann 1985

11905-7

BPD, Jeanty 1984

11906-5

BPD, Kurtz 1980

11907-3

BPD, Sabbagha 1978

11910-7

CRL, Hadlock 1992

11911-5

CRL, Hansmann 1985

11913-1

CRL, Nelson 1981

11914-9

CRL, Robinson 1975

11917-2

CRL, Jeanty 1984

11918-0

Fibula, Merz 1987

11920-6

FL, Hadlock 1984

11921-4

FL, Hansmann 1985

11922-2

FL, Hohler 1982

11923-0

FL, Jeanty 1984

11924-8

FL, Merz 1987

11926-3

Foot Length, Mercer 1987

11928-9

GS, Hellman 1969

11929-7

GS, Rempen 1991

11932-1

HC, Hadlock 1984

11934-7

HC, Jeanty 1984

11936-2

Humerus, Jeanty 1984

11937-0

Humerus, Merz 1987

11939-6

Radius, Merz 1987

11941-2

Tibia, Jeanty 1984

11944-6

Ulna, Jeanty 1984

11945-3

Ulna, Merz 1987

11947-9

HC/AC

11948-7

Fetal Heart Rate

8665-2

Last Menstrual Period

11957-8

Crown Rump Length

11961-0

Cervix Length

11962-8

Clavicle length

11963-6

Femur Length

11964-4

Fibula length

11965-1

Foot length

11966-9

Humerus length

11967-7

Radius length

11968-5

Tibia length

11969-3

Ulna length

11976-8

Ovulation date

11977-6

Para

11979-2

Abdominal Circumference

11984-2

Head Circumference

11988-3

Thoracic Circumference

11996-6

Gravida

12008-9

Pulsatility Index

12023-8

Resistivity Index

12144-2

Systolic to Diastolic Velocity Ratio

12145-9

Endometrium Thickness

12146-7

Nuchal Fold thickness

12164-0

Left Ovary Volume

12165-7

Right Ovary Volume

12170-7

Width of Hemisphere

12171-5

Lateral Ventricle Width

17977-0

Left Atrium Area A4C view

17978-8

Mitral Valve A-Wave Peak Velocity

17985-3

Left Atrium to Aortic Root Ratio

17988-7

Right Atrium Area A4C view

17995-2

Thoracic Aorta Coarctation Systolic Peak Instantaneous Gradient

17996-0

Aortic Valve Cusp Separation

17998-6

Aortic Valve Regurgitant Diastolic Deceleration Time

18006-7

Inferior Vena Cava Diameter

18011-7

Aortic Arch Diameter

18012-5

Ascending Aortic Diameter

18013-3

Descending Aortic Diameter

18015-8

Aortic Root Diameter

18019-0

Left Pulmonary Artery Diameter

18020-8

Main Pulmonary Artery Diameter

18021-6

Right Pulmonary Artery Diameter

18026-5

Left Ventricular End Diastolic Volume

18030-7

Tricuspid Valve A Wave Peak Velocity

18031-5

Tricuspid Valve E Wave Peak Velocity

18035-6

Mitral Regurgitation dP/dt derived from Mitral Reg. velocity

18037-2

Mitral Valve E-Wave Peak Velocity

18038-0

Mitral Valve E to A Ratio

18040-6

Mitral Valve E-F Slope by M-Mode

18041-4

Aortic Valve Ejection Time

18043-0

Left Ventricular Ejection Fraction by US

18050-5

Inferior Vena Cava % Collapse

18051-3

Left Ventricular Fractional Shortening

18053-9

Left Ventricle Posterior Wall % Thickening

18054-7

Interventricular Septum % Thickening

18070-3

Right Atrium Systolic Pressure

18071-1

Left Ventricular Isovolumic Relaxation Time

18076-0

Left Ventricle Systolic Major Axis

18077-8

Left Ventricle Diastolic Major Axis

18087-7

Left Ventricle Mass

18096-8

Pulmonic valve Area by continuity

18118-0

LV Wall Motion Segmental Findings

18139-6

Stage

18148-7

Left Ventricular End Systolic Volume

18152-9

Left Ventricle Posterior Wall Diastolic Thickness

18153-7

Right Ventricle Anterior Wall Diastolic Thickness

18154-5

Interventricular Septum Diastolic Thickness

18155-2

Interventricular Septum to Posterior Wall Thickness Ratio

18156-0

Left Ventricle Posterior Wall Systolic Thickness

18157-8

Right Ventricular Anterior Wall Systolic Thickness

18158-6

Interventricular Septum Systolic Thickness

18179-2

Wall Segment

18185-9

Gestational Age

18745-0

Cardiac Catheterization Report

25045-6

CT Report

18748-4

Diagnostic Imaging Report

25056-3

MRI Report

18756-7

MRI Spine Report

49118-3

Nuclear Medicine Report

44136-0

PET Scan Report

25061-3

Ultrasound Report

18782-3

Findings

18783-1

Recommendations

18785-6

Indications for Procedure

18834-2

Previous Findings

19005-8

Impressions

20167-3

Acceleration Index

20168-1

Acceleration time

20217-6

Deceleration time

20247-3

Peak Gradient

20295-2

Time from Q wave to Pulmonic Valve Closes

20352-1

Time averaged mean velocity

29436-3

Left Ventricle Internal End Diastolic Dimension

29438-9

Left Ventricle Internal Systolic Dimension

29449-6

Mitral Valve Regurgitant Volume by Proximal Isovelocity Surface Area Method

29450-4

Pulmonary Vein Systolic Peak Velocity

29451-2

Pulmonary Vein Diastolic Peak Velocity

29452-0

Pulmonary Vein Systolic to Diastolic Ratio

29453-8

Pulmonary Vein Atrial Contraction Reversal Peak Velocity

29460-3

Thoracic Aorta Coarctation Systolic Peak Velocity

29462-9

Pulmonary-to-Systemic Shunt Flow Ratio

29463-7

Patient Weight

29463-7

Patient weight

29469-4

Left Atrium Antero-posterior Systolic Dimension

29471-0

Hepatic Vein Systolic Peak Velocity

29472-8

Hepatic Vein Diastolic Peak Velocity

29473-6

Hepatic Vein Systolic to Diastolic Ratio

29474-4

Hepatic Vein Atrial Contraction Reversal Peak Velocity

29486-8

Left Atrial Appendage Peak Velocity

29549-3

Medications Administered

33065-4

Ectopic Pregnancies

33066-2

Estimated LMP by EDD

33067-0

Conception Date

33068-8

Thoracic Area

33069-6

Nuchal Translucency

33070-4

Inner Orbital Diameter

33071-2

Spine Length

33072-0

AC, ASUM 2000

33073-8

AC, Hansmann1985

33074-6

AC, Lessoway 1998

33075-3

AC, Mertz 1988

33076-1

AC, Shinozuka 1996

33077-9

A-P Abdominal Diameter, Lessoway 1998

33078-7

AxT, Shinozuka 1996

33079-5

BPD, ASUM 1989

33080-3

BPD, Lessoway 1998

33081-1

BPD, Mertz 1988

33082-9

BPD, Osaka 1989

33083-7

BPD, Rempen 1991

33084-5

BPD, Shinozuka 1996

33085-2

BPD, Tokyo 1986

33086-0

BPD-oi, Chitty 1997

33087-8

BPD-oo, Chitty 1997

33088-6

Clavicle length, Yarkoni 1985

33089-4

CRL, ASUM 1991

33090-2

CRL, ASUM 2000

33091-0

CRL, Daya 1993

33092-8

CRL, Jeanty 1982

33093-6

CRL, Osaka 1989

33094-4

CRL, Rempen 1991

33095-1

CRL, Shinozuka 1996

33096-9

CRL, Tokyo 1986

33097-7

Fibula, Jeanty 1983

33098-5

FL, Chitty 1997

33099-3

FL, Jeanty 1982

33100-9

FL, Lessoway 1998

33101-7

FL, Osaka 1989

33102-5

FL, Shinozuka 1996

33103-3

FL, Tokyo 1986

33104-1

GS, Daya 1991

33105-8

GS, Hansmann 1979

33106-6

GS, Hansmann 1982

33107-4

GS, Nyberg 1992

33108-2

GS, Tokyo 1986

33109-0

HC, ASUM 2000

33110-8

HC measured, Chitty 1997

33111-6

HC derived, Chitty 1997

33112-4

HC, Hansmann 1985

33113-2

HC, Jeanty 1982

33114-0

HC, Lessoway 1998

33115-7

HC Merz, 1988

33116-5

Humerus Length, ASUM 2000

33117-3

Humerus Length, Osaka 1989

33118-1

Length of Vertebra, Tokyo 1986

33119-9

OFD, ASUM 2000

33120-7

OFD, Hansmann 1986

33121-5

OFD, Lessoway 1998

33122-3

IOD, Mayden 1982

33123-1

IOD, Trout 1994

33124-9

OOD, Mayden, 1982

33125-6

OOD, Trout 1994

33126-4

Radius, Jeanty 1983

33127-2

Spine Length, Tokyo, 1989

33128-0

TAD, Eriksen 1985

33129-8

TAD Hansmann, 1979

33130-6

TAD, Tokyo 1986

33131-4

ThC, Chitkara 1987

33132-2

TCD, Chitty 1994

33133-0

TCD, Goldstein 1987

33134-8

TCD, Hill 1990

33135-5

TCD, Nimrod 1986

33136-3

Transverse Thoracic Diameter, Hansmann 1985

33137-1

Transverse Thoracic Diameter, Lessoway 1998

33138-9

Fetal Trunk Cross-Sectional Area, Osaka 1989

33139-7

EFW by BPD, TTD, Hansmann 1986

33140-5

EFW by BPD, FTA, FL, Osaka 1990

33141-3

EFW1 by Shinozuka 1996

33142-1

EFW2 by Shinozuka 1996

33143-9

EFW3 by Shinozuka 1996

33144-7

EFW by BPD, APAD, TAD, FL, Tokyo 1987

33145-4

AC by GA, ASUM 2000

33146-2

AC by GA, Hadlock 1984

33147-0

AC (measured) by GA, Chitty 1994

33147-0

AC (measured) by GA, Chitty 1994

33148-8

AC by GA, Merz 1988

33149-6

AC by GA, Shinozuka 1996

33150-4

AxT by GA, Shinozuka 1996

33151-2

BPD by GA, ASUM 2000

33152-0

BPD outer-outer by GA, Chitty 1994

33153-8

BPD by GA, Jeanty 1982

33154-6

BPD by GA, Merz 1988

33155-3

BPD by GA, Rempen 1991

33156-1

BPD by GA, Shinozuka 1996

33157-9

Cephalic Index, by GA Chitty 1994

33158-7

Cephalic Index by GA, Hadlock 1981

33159-5

CRL by GA, ASUM 2000

33160-3

CRL by GA, Rempen1991

33161-1

CRL, by GA, Shinozuka 1996

33162-9

EFW by GA, Hadlock 1991

33163-7

EFW by GA, Hansmann 1986

33164-5

Fibula by GA, Jeanty 1983

33165-2

FL by GA, ASUM 2000

33166-0

FL by GA, Hadlock 1984

33167-8

FL by GA, Chitty 1994

33168-6

FL by GA, Jeanty 1982

33169-4

FL by GA, Merz 1988

33170-2

FL by GA, Shinozuka 1996

33171-0

GS by GA, Rempen 1991

33172-8

HC by GA, ASUM 2000

33173-6

HC by GA, Hadlock 1984

33174-4

HC derived by GA, Chitty 1994

33175-1

HC by GA, Jeanty 1982

33176-9

HC by GA, Merz 1988

33177-7

Humerus Length by GA, ASUM 2000

33178-5

OFD by GA, ASUM 2000

33179-3

OFD by GA, Chitty 1994

33180-1

Radius, by GA, Jeanty 1983

33181-9

TCD by GA, Goldstein 1987

80416-1

HC/AC by GA, Campbell 1977

33184-3

FWP by GA, Williams, 1982

33185-0

FWP by GA, Alexander, 1996

33186-8

Male Singleton BWP by GA, Arbuckle 1993

33187-6

Female Singleton BWP by GA, Arbuckle 1993

33188-4

Female Twins BWP by GA, Arbuckle 1993

33189-2

FWP by GA, Brenner 1976

33190-0

FWP by GA, Hadlock 1985

33191-8

APAD * TAD

33192-6

Uterus Volume

33196-7

Posterior Horn Lateral ventricular width

33197-5

Anterior Horn Lateral ventricular width

33198-3

BPD by GA, Hadlock 1984

33199-1

Male Twins BWP by GA, Arbuckle 1993

33537-2

AC, Jeanty 1982

33538-0

BPD, Hansmann 1986

33539-8

BPD, Jeanty 1982

33540-6

CRL, Hansmann 1986

33541-4

FL, Hansmann 1986

33542-2

FL, Merz 1988

33543-0

HC, Hansmann 1986

33544-8

OFD, Hansmann 1985

33545-5

BD, Jeanty 1982

33546-3

AC (derived) by GA, Chitty 1994

33556-2

BPD outer-inner by GA, Chitty 1994

33867-3

Velocity ratio

33868-1

ICA/CCA velocity ratio

33869-9

Renal Artery/Aorta velocity ratio

55107-7

Addendum

55108-5

Patient Presentation

55109-3

Complications

55110-1

Conclusions

55111-9

Current Procedure Descriptions

55112-7

Summary

55113-5

Key Images

55114-3

Prior Procedure Descriptions

55115-0

Request

55281-0

Number of Fetuses

55752-0

Clinical Information

73568-8

Communication of Critical Results

73569-6

Radiation Exposure and Protection Information

8277-6

Body Surface Area

8302-2

Patient Height

11627-7

Amniotic Fluid Index

53684-7

Left Fetal Ear Length

53668-0

Right Fetal Ear Length


Note

LN:33183-5 was previously included in this context group with a Code Meaning of "FWP by GA, Hadlock 1991", but is described in LOINC as "Fetal body weight growth percentile estimated from gestational age by method of Campbell 1991 (US)". Devices receiving LN:33183-5 may need to consult the Code Meaning value to determine whether the sender meant Hadlock 1991 or Campbell 1991. New codes have been defined to replace LN:33183-5 to resolve the potential ambiguity.

DICOM PS3.16 2022a - Content Mapping Resource