DICOM PS3.11 2022a - Media Storage Application Profiles

3 Definitions

For the purposes of this Standard the following definitions apply.

3.1 Reference Model Definitions

This Part of the Standard makes use of the following terms defined in [ISO 7498-1] and [ISO 7498-2]:

Application Entity

See [ISO 7498-1].

Service

See [ISO 7498-1].

Transfer Syntax

See [ISO 7498-1].

Data Confidentiality

See [ISO 7498-2].

Note

The definition is "the property that information is not made available or disclosed to unauthorized individuals, entities or processes."

Data Origin Authentication

See [ISO 7498-2].

Note

The definition is "the corroboration that the source of data received is as claimed."

Data Integrity

See [ISO 7498-2].

Note

The definition is "the property that data has not been altered or destroyed in an unauthorized manner."

Key Management

See [ISO 7498-2].

Note

The definition is "the generation, storage, distribution, deletion, archiving and application of keys in accordance with a security policy."

3.2 DICOM Introduction and Overview Definitions

This Part of the Standard makes use of the following terms defined in PS3.1 of the DICOM Standard:

Attribute

Attribute.

Service Object Pair Class (SOP Class)

Service-Object Pair Class (SOP Class).

3.3 DICOM Conformance

This Part of the Standard makes use of the following terms defined in PS3.2 of the DICOM Standard:

Conformance Statement

Conformance Statement.

Standard SOP Class

Standard SOP Class.

Standard Extended SOP Class

Standard Extended SOP Class.

Specialized SOP Class

Specialized SOP Class.

Private SOP Class

Private SOP Class.

Standard Application Profile

Standard Application Profile.

Augmented Application Profile

Augmented Application Profile.

Private Application Profile

Private Application Profile.

3.4 DICOM Information Object Definitions

This Part of the Standard makes use of the following terms defined in PS3.3 of the DICOM Standard:

Information Object Definition (IOD)

Information Object Definition.

Basic Directory IOD

Basic Directory IOD.

Basic Directory Information Model

Basic Directory Information Model.

3.5 DICOM Data Structure and Encoding Definitions

This Part of the Standard makes use of the following terms defined in PS3.5 of the DICOM Standard:

Data Element

Data Element.

Data Set

Data Set.

3.6 DICOM Message Exchange Definitions

This Part of the Standard makes use of the following terms defined in PS3.7 of the DICOM Standard:

Implementation Class UID

Implementation Class UID.

3.7 DICOM Media Storage and File Format Definitions

This Part of the Standard makes use of the following terms defined in PS3.10 of the DICOM Standard:

Application Profile

Media Storage Application Profile.

DICOM File Format

DICOM File Format.

DICOM File Service

DICOM File Service.

DICOM File

DICOM File.

DICOMDIR File

DICOMDIR File.

File

File.

File ID

File ID.

File Meta Information

File Meta Information.

File-set

File-set.

DICOM Media Storage Model

DICOM Media Storage Model.

Secure DICOM File

Secure DICOM File.

Secure Media Storage Application Profile

Secure Media Storage Application Profile.

3.8 Media Storage Application Profiles

The following definitions are commonly used in this Part of the Standard:

Media Storage Application Profile Class

A group of related Media Storage Application Profiles defined in a single Annex to PS3.11.

3.9 DICOM Service Class Definitions

This Part of the Standard makes use of the following terms defined in PS3.4 of the DICOM Standard:

Service Object Pair Instance (SOP Instance)

Service-Object Pair Instance (SOP Instance).

DICOM PS3.11 2022a - Media Storage Application Profiles