DICOM PS3.4 2022a - Service Class Specifications

P.2.2.4 Status Codes

Table P.2-3 defines the specific status code values that might be returned in a N-ACTION response. See PS3.7 for additional general response status codes.

Table P.2-3. Response Status

Service Status

Further Meaning

Status Code

Success

0000

Warning

Specified Synchronization Frame of Reference UID does not match SCP Synchronization Frame of Reference

B101

Study Instance UID coercion; Event logged under a different Study Instance UID

B102

IDs inconsistent in matching a current study; Event logged

B104

Failure

Failed: Procedural Logging not available for specified Study Instance UID

C101

Failed: Event Information does not match Template

C102

Failed: Cannot match event to a current study

C103

Failed: IDs inconsistent in matching a current study; Event not logged

C104


DICOM PS3.4 2022a - Service Class Specifications