| DICOM PS3.4 2022a - Service Class Specifications |
|---|
The Non-Patient Object Storage Service Class defines an application-level class-of-service that allows one DICOM AE to send a SOP Instance of a non-patient-related information object to another DICOM AE.
The Non-Patient Object Storage Service Class includes several SOP Classes, each using an IOD defined in PS3.3 (see Section GG.3). The Non-Patient Object Storage Service Class uses the C-STORE DIMSE Service specified in PS3.7. A successful completion of the C-STORE has the following semantics:
Support for the Non-Patient Object Storage Service Class does not imply support for any related Query/Retrieve Service Classes.
The duration of the storage is also implementation dependent, but is described in the Conformance Statement of the SCP.
The Non-Patient Object Storage Service Class is intended to be used in a variety of environments: e.g., for workstations to transfer SOP Instances to other workstations or archives, for archives to transfer SOP Instances to workstations, etc.
| DICOM PS3.4 2022a - Service Class Specifications |
|---|