| DICOM PS3.3 2022a - Information Object Definitions |
|---|
Table C.7-18 describes the Attributes of devices or calibration objects (e.g., catheters, markers, baskets) that are associated with a Study and/or image.
Table C.7-18. Device Module Attributes
|
A Sequence of Items describing devices used that may be visible in the image. |
|||
|
Length in mm of device. See Section C.7.6.12.1.1. |
|||
|
Unit diameter of device. See Section C.7.6.12.1.1. |
|||
|
Volume of device in ml. See Section C.7.6.12.1.1. |
|||
|
Distance in mm between markers on calibrated device. See Section C.7.6.12.1.1. |
|||
|
Further description in free form text describing the device. |
|||
Depending on the type of device specified by Code Value (0008,0100) in an Item of Device Sequence (0050,0010), various device size Attributes (e.g., Device Length (0050,0014), Device Diameter (0050,0016), Device Volume (0050,0018), Inter Marker Distance (0050,0019)) may be required to fully characterize the device.