| DICOM PS3.3 2022a - Information Object Definitions |
|---|
Table C.4-13 specifies the Attributes used to reference other SOP Classes and other Information Entities of the DICOM real-world model as defined in Section 7.3.1.6.
Table C.4-13. Performed Procedure Step Relationship Module Attributes
|
Primary identifier for the Patient. NoteIn the case of imaging a group of small animals simultaneously, the single value of this identifier corresponds to the identification of the entire group. See also Section C.7.1.4.1.1. |
||
|
Date of birth of the named Patient in the Alternative Calendar (0010,0035). |
||
|
Date of death of the named Patient in the Alternative Calendar (0010,0035). |
||
|
The Alternative Calendar used for Patient's Birth Date in Alternative Calendar (0010,0033) and Patient's Death Date in Alternative Calendar (0010,0034). See Section C.7.1.5 for Defined Terms. Required if either Patient's Birth Date in Alternative Calendar (0010,0033) or Patient's Alternative Death Date in Calendar (0010,0034) is present. |
||
|
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
||
|
Identification number of the Visit as assigned by the healthcare provider. |
||
|
Identifier of the Assigning Authority that issued the Admission ID. |
||
|
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
Identifier of the Service Episode as assigned by the healthcare provider |
||
|
Identifier of the Assigning Authority that issued the Service Episode ID. |
||
|
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
Sequence containing Attributes that are related to the scheduling of the Procedure Step. |
||
|
Uniquely identifies the Study SOP Instance associated with this Scheduled Procedure Step. Only a single Item shall be included in this Sequence. See Section 10.6.1. |
||
|
>>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
||
|
A departmental Information System generated number that identifies the Imaging Service Request. |
||
|
Identifier of the Assigning Authority that issued the Accession Number. |
||
|
>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
The order number assigned to the Imaging Service Request by the party placing the order. |
||
|
Identifier of the Assigning Authority that issued the Placer Order Number. |
||
|
>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
The order number assigned to the Imaging Service Request by the party filling the order. |
||
|
Identifier of the Assigning Authority that issued the Filler Order Number. |
||
|
>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
||
|
Institution-generated administrative description or classification of Requested Procedure. |
||
|
A Sequence that conveys the Procedure Type of the requested procedure. |
||
|
Institution-generated description or classification of the Scheduled Procedure Step to be performed. |
||
|
Sequence describing the Scheduled Protocol following a specific coding scheme. |
||
|
Sequence that specifies the context for the Scheduled Protocol Code Sequence (0040,0008) Item. One or more Items shall be included in this Sequence. See Section C.4.10.1. |
||
|
>>>Include Table 10-2 “Content Item Macro Attributes” |
||
|
Sequence that specifies modifiers for a Protocol Context Content Item. One or more Items shall be included in this Sequence. See Section C.4.10.1. |
||
|
>>>>Include Table 10-2 “Content Item Macro Attributes” |
||
The Patient information is included in order to relate the Modality Performed Procedure Step SOP Instance to the Study Management SOP Instance and other associated IODs in case the SCU (the modality) is unable to obtain or use the Study Instance UID created by the Information System.
Placer Order Number / Imaging Service Request (0040,2016) and Filler Order Number / Imaging Service Request (0040,2017) are intended to convey the corresponding order numbers as defined in HL7, in the case where interoperability with an HL7 environment is the objective.
Attributes (0040,2006) and (0040,2007) were previously defined in DICOM. They are now retired (see PS3.3-1998).
Placer Order Number / Procedure (0040,1006) and Filler Order Number / Procedure (0040,1007) were previously defined in DICOM. They are now retired (see PS3.3-1998).
| DICOM PS3.3 2022a - Information Object Definitions |
|---|