Table C.2-3 defines the Attributes relevant to generally describing a Patient at a specific point in time, e.g., at the time of admission.
Table C.2-3. Patient Demographic Module Attributes
|
Special indication to the modality operator about confidentiality of Patient information (e.g., that he should not use the Patient's name where other patients are present). |
||
|
Indicates whether or not the subject is a quality control phantom. If this Attribute is absent, then the subject may or may not be a phantom. This Attribute describes a characteristic of the Imaging Subject. It is distinct from Quality Control Image (0028,0300) in the General Image Module, which is used to describe an image acquired. |
||
|
A Sequence that conveys the Patient's insurance plan. Zero or more Items shall be included in this Sequence. |
||
|
The languages that can be used to communicate with the Patient. Zero or more Items shall be included in this Sequence. The Items are ordered by preference (most preferred language to least preferred language). |
||
|
A modifier for a Patient's Primary Language. Can be used to specify a national language variant. |
||
|
BCID 7039 “Pediatric Size Categories” for pediatric patients. |
||
|
Branch of the military. The country allegiance may also be included (e.g., U.S. Army). |
||
|
The Patient's personal telecommunication contact information, including telephone, email, or other telecom addresses. Note
|
||
|
Name of person with medical or welfare decision making authority for the Patient. |
||
|
Relationship of Responsible Person to the Patient. See Section C.7.1.1.1.2 for Defined Terms. |
||
|
Name of organization with medical or welfare decision making authority for the Patient. |
||
|
The taxonomic rank value (e.g., genus, subgenus, species or subspecies) of the Patient. See Section C.7.1.1.1.3. |
||
|
The taxonomic rank value (e.g., genus, subgenus, species or subspecies) of the Patient. See Section C.7.1.1.1.3. |
||
|
The breed of the Patient. See Section C.7.1.1.1.1. |
||
|
The breed of the Patient. See Section C.7.1.1.1.1. |
||
|
Identification number of a veterinary patient within the registry. |
||
|
Identification of the organization with which an animal is registered. |
||
|
The strain of the Patient. See Section C.7.1.1.1.4. |
||
|
The nomenclature used for Strain Description (0010,0212). See Section C.7.1.1.1.4. |
||
|
A coded identification of the strain of the Patient. See Section C.7.1.1.1.4. One or more Items are permitted in this Sequence. If more than one Item is present, each Item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers). |
||
|
Additional information about the strain of the Patient that is not encoded in the formal nomenclature used in Strain Description (0010,0212). See Section C.7.1.1.1.4. |
||
|
The stock number of the strain of the Patient issued by the organization identified by Strain Source (0010,0217). See Section C.7.1.1.1.4. |
||
|
Identification of the organization that is the source of the animal, issued by the registry identified by Strain Source Registry Code Sequence (0010,0215). See Section C.7.1.1.1.4. |
||
|
Identification of the organization that is the registry of sources of animals. See Section C.7.1.1.1.4. |
||
|
The genetic modifications of the Patient. One or more Items are permitted in this Sequence. See Section C.7.1.1.1.4. |
||
|
The genetic modifications of the Patient described using a specific nomenclature. |
||
|
The nomenclature used for Genetic Modifications Description (0010,0222). |
||
|
A coded identification of the genetic modifications of the Patient. One or more Items are permitted in this Sequence. If more than one Item is present, each Item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers). |
||
The language codes specified in CID 5000 “Languages”, used in Patient's Primary Language Code Sequence (0010,0101), optionally allow the encoding of the country of language in the code value for the language. Encoding of the country of language in a subsidiary Patient's Primary Language Modifier Code Sequence (0010,0102) is allowed for backward compatibility with previous editions of the Standard.