DICOM PS3.3 2022a - Information Object Definitions

10.22 Numeric Value Macro

Table 10-26 describes the Attributes used to relate and convey a numeric value to a coded concept.

Table 10-26. Numeric Value Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Concept Name Code Sequence

(0040,A043)

1

Coded concept name of this name-value Item.

Only a single Item shall be included in this Sequence.

>Include Table 8.8-1 “Code Sequence Macro Attributes”

No Context ID is defined.

Numeric Value

(0040,A30A)

1

Numeric value for this name-value Item.

Measurement Units Code Sequence

(0040,08EA)

1

Units of Numeric Value (0040,A30A) in this name-value Item.

Only a single Item shall be included in this Sequence.

>Include Table 8.8-1 “Code Sequence Macro Attributes”

DCID 82 “Units of Measurement”.


DICOM PS3.3 2022a - Information Object Definitions