DICOM PS3.2 2022a - Conformance
G.4.2.3.2 Association Policies
G.4.2.3.2.1 General

FIND-SCU initiates but never accepts associations.

Table G.4.2-14. Maximum PDU Size Received as a SCP for FIND-SCU

Maximum PDU size received

Unlimited


G.4.2.3.2.2 Number of Associations

Table G.4.2-15. Number of Associations as a SCP for FIND-SCU

Maximum number of simultaneous associations

1


G.4.2.3.2.3 Asynchronous Nature

FIND-SCU will only allow a single outstanding operation on an Association. Therefore, FIND-SCU will not perform asynchronous operations window negotiation.

G.4.2.3.2.4 Implementation Identifying Information

Table G.4.2-16. DICOM Implementation Class and Version for FIND-SCU

Implementation Class UID

1.2.840.999999.3.6

Implementation Version Name

Viewer1.0


DICOM PS3.2 2022a - Conformance