DICOM PS3.16 2019a - Content Mapping Resource

TID 4204 Breast Imaging Report Intervention Section

This Template defines a supplementary data section for an Intervention of the breast, for the Breast Imaging Report. It is included from TID 4208 “Breast Imaging Report Supplementary Data”.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 4204. Breast Imaging Report Intervention Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111463, DCM, "Supplementary Data for Intervention")

1

M

2

>

CONTAINS

INCLUDE

DTID 4201 “Breast Imaging Procedure Reported”

1

M

3

>

CONTAINS

CODE

EV (A-00110, SRT, "Instrument")

1

U

4

>>

HAS PROPERTIES

TEXT

EV (111465, DCM, "Needle Gauge")

1

UC

XOR row 5

5

>>

HAS PROPERTIES

CODE

EV (111465, DCM, "Needle Gauge")

1

UC

XOR row 4

6

>>

HAS PROPERTIES

NUM

EV (111467, DCM, "Needle Length")

1

U

UNITS = EV (cm, UCUM, "centimeter")

7

>

CONTAINS

NUM

EV (111436, DCM, "Number of passes")

1

U

UNITS = EV ({passes}, UCUM, "passes")

8

>

CONTAINS

NUM

EV (111437, DCM, "Number of specimens")

1

U

UNITS = EV ({specimens}, UCUM, "specimens")

9

>

CONTAINS

CODE

EV (111431, DCM, "Instrument Approach")

1-n

U

DCID 6065 “Instrument Approach”

10

>

CONTAINS

CODE

EV (111438, DCM, "Needle in target")

1

U

DCID 230 “Yes-No”

11

>

CONTAINS

NUM

EV (111439, DCM, "Number of needles around target")

1

U

UNITS = EV ({needles}, UCUM, "needles")

12

>

CONTAINS

CODE

EV (F-04460, SRT, "Medication given")

1-n

U

13

>

CONTAINS

CODE

EV (111440, DCM, "Incision made")

1

U

DCID 230 “Yes-No”

14

>

CONTAINS

CODE

EV (111123, DCM, "Marker placement")

1

U

DCID 230 “Yes-No”

15

>

CONTAINS

CODE

EV (111442, DCM, "Confirmation of target")

1

U

DCID 6066 “Target Confirmation”

16

>

CONTAINS

CODE

EV (DD-60002, SRT, "Complication of procedure")

1-n

U

DCID 6062 “Interventional Procedure Complications”

17

>>

HAS PROPERTIES

CODE

EV (111466, DCM, "Severity of Complication")

1

U

DCID 251 “Severity of Complication”

18

>

CONTAINS

CONTAINER

EV (121027, DCM, "Specimen")

1-n

U

19

>>

HAS OBS CONTEXT

INCLUDE

DTID 1009 “Subject Context, Specimen”

1

U

20

>>

CONTAINS

CODE

EV (F-00E6D, SRT, "Color of fluid")

1

U

DCID 6067 “Fluid Color”

21

>>

CONTAINS

CODE

EV (111456, DCM, "Action on fluid")

1

U

DT (111457, DCM, "Sent for analysis")

DT (111458, DCM, "Discarded")

22

>>

CONTAINS

CODE

EV (111455, DCM, "Occult blood test result")

1

U

DCID 250 “Positive-Negative”

23

>>

CONTAINS

INCLUDE

DTID 4207 “Breast Imaging Pathology Results”

1-n

U

24

>

CONTAINS

INCLUDE

DTID 350 “References to Supporting Evidence”

1

U


DICOM PS3.16 2019a - Content Mapping Resource