DICOM PS3.6 2018e - Data Dictionary

A Registry of DICOM Unique Identifiers (UIDs) (Normative)

Table A-1 lists the UID values that are registered and used throughout the Parts of the DICOM Standard. This central registry ensures that when additional UIDs are assigned, non-duplicate values are assigned.

Table A-1. UID Values

UID Value

UID Name

UID Type

Part

1.2.840.10008.1.​1

Verification SOP Class

SOP Class

PS3.4

1.2.840.10008.1.​2

Implicit VR Little Endian: Default Transfer Syntax for DICOM

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​1

Explicit VR Little Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​1.​99

Deflated Explicit VR Little Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​2

Explicit VR Big Endian (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​50

JPEG Baseline (Process 1): Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​51

JPEG Extended (Process 2 & 4): Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​52

JPEG Extended (Process 3 & 5) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​53

JPEG Spectral Selection, Non-Hierarchical (Process 6 & 8) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​54

JPEG Spectral Selection, Non-Hierarchical (Process 7 & 9) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​55

JPEG Full Progression, Non-Hierarchical (Process 10 & 12) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​56

JPEG Full Progression, Non-Hierarchical (Process 11 & 13) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​57

JPEG Lossless, Non-Hierarchical (Process 14)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​58

JPEG Lossless, Non-Hierarchical (Process 15) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​59

JPEG Extended, Hierarchical (Process 16 & 18) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​60

JPEG Extended, Hierarchical (Process 17 & 19) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​61

JPEG Spectral Selection, Hierarchical (Process 20 & 22) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​62

JPEG Spectral Selection, Hierarchical (Process 21 & 23) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​63

JPEG Full Progression, Hierarchical (Process 24 & 26) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​64

JPEG Full Progression, Hierarchical (Process 25 & 27) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​65

JPEG Lossless, Hierarchical (Process 28) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​66

JPEG Lossless, Hierarchical (Process 29) (Retired)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​70

JPEG Lossless, Non-Hierarchical, First-Order Prediction (Process 14 [Selection Value 1]): Default Transfer Syntax for Lossless JPEG Image Compression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​80

JPEG-LS Lossless Image Compression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​81

JPEG-LS Lossy (Near-Lossless) Image Compression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​90

JPEG 2000 Image Compression (Lossless Only)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​91

JPEG 2000 Image Compression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​92

JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​93

JPEG 2000 Part 2 Multi-component Image Compression

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​94

JPIP Referenced

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​95

JPIP Referenced Deflate

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​100

MPEG2 Main Profile / Main Level

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​101

MPEG2 Main Profile / High Level

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​102

MPEG-4 AVC/H.264 High Profile / Level 4.1

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​103

MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​104

MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​105

MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​106

MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.107

HEVC/H.265 Main Profile / Level 5.1

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.108

HEVC/H.265 Main 10 Profile / Level 5.1

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​5

RLE Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​6.​1

RFC 2557 MIME encapsulation (Retired)

Transfer Syntax

PS3.10

1.2.840.10008.1.2.​6.​2

XML Encoding (Retired)

Transfer Syntax

PS3.10

1.2.840.10008.1.​3.​10

Media Storage Directory Storage

SOP Class

PS3.4

1.2.840.10008.1.4.​1.​1

Talairach Brain Atlas Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​2

SPM2 T1 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​3

SPM2 T2 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​4

SPM2 PD Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​5

SPM2 EPI Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​6

SPM2 FIL T1 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​7

SPM2 PET Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​8

SPM2 TRANSM Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​9

SPM2 SPECT Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​10

SPM2 GRAY Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​11

SPM2 WHITE Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​12

SPM2 CSF Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​13

SPM2 BRAINMASK Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​14

SPM2 AVG305T1 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​15

SPM2 AVG152T1 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​16

SPM2 AVG152T2 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​17

SPM2 AVG152PD Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​1.​18

SPM2 SINGLESUBJT1 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​2.​1

ICBM 452 T1 Frame of Reference

Well-known frame of reference

1.2.840.10008.1.4.​2.​2

ICBM Single Subject MRI Frame of Reference

Well-known frame of reference

1.2.840.10008.1.​5.​1

Hot Iron Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​2

PET Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​3

Hot Metal Blue Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​4

PET 20 Step Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​5

Spring Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​6

Summer Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​7

Fall Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​5.​8

Winter Color Palette SOP Instance

Well-known SOP Instance

PS 3.6

1.2.840.10008.1.​9

Basic Study Content Notification SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.1.​20

Papyrus 3 Implicit VR Little Endian (Retired)

Transfer Syntax

1.2.840.10008.1.​20.​1

Storage Commitment Push Model SOP Class

SOP Class

PS3.4

1.2.840.10008.1.20.​1.​1

Storage Commitment Push Model SOP Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​20.​2

Storage Commitment Pull Model SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.1.20.​2.​1

Storage Commitment Pull Model SOP Instance (Retired)

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​40

Procedural Event Logging SOP Class

SOP Class

PS3.4

1.2.840.10008.1.​40.​1

Procedural Event Logging SOP Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​42

Substance Administration Logging SOP Class

SOP Class

PS3.4

1.2.840.10008.1.​42.​1

Substance Administration Logging SOP Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.2.​6.​1

DICOM UID Registry

DICOM UIDs as a Coding Scheme

PS 3.6

1.2.840.10008.2.​16.​4

DICOM Controlled Terminology

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​5

Adult Mouse Anatomy Ontology

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​6

Uberon Ontology

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​7

Integrated Taxonomic Information System (ITIS) Taxonomic Serial Number (TSN)

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​8

Mouse Genome Initiative (MGI)

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​9

PubChem Compound CID

Coding Scheme

PS3.16

1.2.840.10008.3.1.​1.​1

DICOM Application Context Name

Application Context Name

PS3.7

1.2.840.10008.3.1.2.​1.​1

Detached Patient Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.3.1.2.​1.​4

Detached Patient Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.3.1.2.​2.​1

Detached Visit Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​1

Detached Study Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​2

Study Component Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​3

Modality Performed Procedure Step SOP Class

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​4

Modality Performed Procedure Step Retrieve SOP Class

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​5

Modality Performed Procedure Step Notification SOP Class

SOP Class

PS3.4

1.2.840.10008.3.1.2.​5.​1

Detached Results Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.3.1.2.​5.​4

Detached Results Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.3.1.2.​5.​5

Detached Study Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.3.1.2.​6.​1

Detached Interpretation Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.4.​2

Storage Service Class

Service Class

PS3.4

1.2.840.10008.5.1.​1.​1

Basic Film Session SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​2

Basic Film Box SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​4

Basic Grayscale Image Box SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.1.​4.​1

Basic Color Image Box SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.1.​4.​2

Referenced Image Box SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​9

Basic Grayscale Print Management Meta SOP Class

Meta SOP Class

PS3.4

1.2.840.10008.5.1.1.​9.​1

Referenced Grayscale Print Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.5.1.​1.​14

Print Job SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​15

Basic Annotation Box SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​16

Printer SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.1.​16.​376

Printer Configuration Retrieval SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​17

Printer SOP Instance

Well-known Printer SOP Instance

PS3.4

1.2.840.10008.5.1.1.​17.​376

Printer Configuration Retrieval SOP Instance

Well-known Printer SOP Instance

PS3.4

1.2.840.10008.5.1.​1.​18

Basic Color Print Management Meta SOP Class

Meta SOP Class

PS3.4

1.2.840.10008.5.1.1.​18.​1

Referenced Color Print Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.5.1.​1.​22

VOI LUT Box SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​23

Presentation LUT SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​24

Image Overlay Box SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.1.​24.​1

Basic Print Image Overlay Box SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​25

Print Queue SOP Instance (Retired)

Well-known Print Queue SOP Instance

PS3.4

1.2.840.10008.5.1.​1.​26

Print Queue Management SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​27

Stored Print Storage SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​29

Hardcopy Grayscale Image Storage SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​30

Hardcopy Color Image Storage SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​31

Pull Print Request SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​32

Pull Stored Print Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.5.1.​1.​33

Media Creation Management SOP Class UID

SOP Class

PS3.4

1.2.840.10008.5.1.1.40

Display System SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.1.40.1

Display System SOP Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.1.​1.​1

Computed Radiography Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​1

Digital X-Ray Image Storage - For Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​1.​1

Digital X-Ray Image Storage - For Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​2

Digital Mammography X-Ray Image Storage - For Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​2.​1

Digital Mammography X-Ray Image Storage - For Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​3

Digital Intra-Oral X-Ray Image Storage - For Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​3.​1

Digital Intra-Oral X-Ray Image Storage - For Processing

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​2

CT Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​2.​1

Enhanced CT Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​2.​2

Legacy Converted Enhanced CT Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​3

Ultrasound Multi-frame Image Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​3.​1

Ultrasound Multi-frame Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​4

MR Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​1

Enhanced MR Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​2

MR Spectroscopy Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​3

Enhanced MR Color Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​4

Legacy Converted Enhanced MR Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​5

Nuclear Medicine Image Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​6

Ultrasound Image Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​6.​1

Ultrasound Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​6.​2

Enhanced US Volume Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​7

Secondary Capture Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​1

Multi-frame Single Bit Secondary Capture Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​2

Multi-frame Grayscale Byte Secondary Capture Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​3

Multi-frame Grayscale Word Secondary Capture Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​4

Multi-frame True Color Secondary Capture Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​8

Standalone Overlay Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​9

Standalone Curve Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​9.​1

Waveform Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​1

12-lead ECG Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​2

General ECG Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​3

Ambulatory ECG Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​2.​1

Hemodynamic Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​3.​1

Cardiac Electrophysiology Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​4.​1

Basic Voice Audio Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​4.​2

General Audio Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​5.​1

Arterial Pulse Waveform Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​6.​1

Respiratory Waveform Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​10

Standalone Modality LUT Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​11

Standalone VOI LUT Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​1

Grayscale Softcopy Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​2

Color Softcopy Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​3

Pseudo-Color Softcopy Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​4

Blending Softcopy Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​5

XA/XRF Grayscale Softcopy Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​6

Grayscale Planar MPR Volumetric Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​7

Compositing Planar MPR Volumetric Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​8

Advanced Blending Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​9

Volume Rendering Volumetric Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​10

Segmented Volume Rendering Volumetric Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​11

Multiple Volume Rendering Volumetric Presentation State Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​1

X-Ray Angiographic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.12.​1.​1

Enhanced XA Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​2

X-Ray Radiofluoroscopic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.12.​2.​1

Enhanced XRF Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​3

X-Ray Angiographic Bi-Plane Image Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​77

(Retired)

SOP Class

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​1

X-Ray 3D Angiographic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​2

X-Ray 3D Craniofacial Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​3

Breast Tomosynthesis Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.1.4.1.1.13.1.4

Breast Projection X-Ray Image Storage - For Presentation

SOP Class

PS3.4

1.2.840.10008.​5.1.4.1.1.13.1.5

Breast Projection X-Ray Image Storage - For Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​14.​1

Intravascular Optical Coherence Tomography Image Storage - For Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​14.​2

Intravascular Optical Coherence Tomography Image Storage - For Processing

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​20

Nuclear Medicine Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​30

Parametric Map Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​40

(Retired)

SOP Class

1.2.840.10008.5.1.4.1.​1.​66

Raw Data Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​1

Spatial Registration Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​2

Spatial Fiducials Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​3

Deformable Spatial Registration Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​4

Segmentation Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​5

Surface Segmentation Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​6

Tractography Results Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​67

Real World Value Mapping Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​68.​1

Surface Scan Mesh Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​68.​2

Surface Scan Point Cloud Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​77.​1

VL Image Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​77.​2

VL Multi-frame Image Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​1

VL Endoscopic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​1.​1

Video Endoscopic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​2

VL Microscopic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​2.​1

Video Microscopic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​3

VL Slide-Coordinates Microscopic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​4

VL Photographic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​4.​1

Video Photographic Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​1

Ophthalmic Photography 8 Bit Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​2

Ophthalmic Photography 16 Bit Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​3

Stereometric Relationship Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​4

Ophthalmic Tomography Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​5

Wide Field Ophthalmic Photography Stereographic Projection Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​6

Wide Field Ophthalmic Photography 3D Coordinates Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​7

Ophthalmic Optical Coherence Tomography En Face Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​8

Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​6

VL Whole Slide Microscopy Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​1

Lensometry Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​2

Autorefraction Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​3

Keratometry Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​4

Subjective Refraction Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​5

Visual Acuity Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​6

Spectacle Prescription Report Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​7

Ophthalmic Axial Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​8

Intraocular Lens Calculations Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​79.​1

Macular Grid Thickness and Volume Report Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​80.​1

Ophthalmic Visual Field Static Perimetry Measurements Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​81.​1

Ophthalmic Thickness Map Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​82.​1

Corneal Topography Map Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​1

Text SR Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​2

Audio SR Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​3

Detail SR Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​4

Comprehensive SR Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​11

Basic Text SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​22

Enhanced SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​33

Comprehensive SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​34

Comprehensive 3D SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​35

Extensible SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​40

Procedure Log Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​50

Mammography CAD SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​59

Key Object Selection Document Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​65

Chest CAD SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​67

X-Ray Radiation Dose SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​68

Radiopharmaceutical Radiation Dose SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​69

Colon CAD SR Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​70

Implantation Plan SR Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​71

Acquisition Context SR Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​72

Simplified Adult Echo SR Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​73

Patient Radiation Dose SR Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​74

Planned Imaging Agent Administration SR Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​75

Performed Imaging Agent Administration SR Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​90.​1

Content Assessment Results Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​1

Encapsulated PDF Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​2

Encapsulated CDA Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​3

Encapsulated STL Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​128

Positron Emission Tomography Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​128.​1

Legacy Converted Enhanced PET Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​129

Standalone PET Curve Storage (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​130

Enhanced PET Image Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​131

Basic Structured Display Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.1

CT Defined Procedure Protocol Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.2

CT Performed Procedure Protocol Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.3

Protocol Approval Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.4

Protocol Approval Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.5

Protocol Approval Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.6

Protocol Approval Information Model - GET

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​1

RT Image Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​2

RT Dose Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​3

RT Structure Set Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​4

RT Beams Treatment Record Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​5

RT Plan Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​6

RT Brachy Treatment Record Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​7

RT Treatment Summary Record Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​8

RT Ion Plan Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​9

RT Ion Beams Treatment Record Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​10

RT Physician Intent Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​11

RT Segment Annotation Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​501.​1

DICOS CT Image Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.501.​2.​1

DICOS Digital X-Ray Image Storage - For Presentation

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.501.​2.​2

DICOS Digital X-Ray Image Storage - For Processing

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​3

DICOS Threat Detection Report Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​4

DICOS 2D AIT Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​5

DICOS 3D AIT Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​6

DICOS Quadrupole Resonance (QR) Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​601.​1

Eddy Current Image Storage

SOP Class

DICONDE ASTM E2934

1.2.840.10008.​5.​1.​4.​1.​1.​601.​2

Eddy Current Multi-frame Image Storage

SOP Class

DICONDE ASTM E2934

1.2.840.10008.5.1.4.1.2.​1.​1

Patient Root Query/Retrieve Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​1.​2

Patient Root Query/Retrieve Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​1.​3

Patient Root Query/Retrieve Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​1

Study Root Query/Retrieve Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​2

Study Root Query/Retrieve Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​3

Study Root Query/Retrieve Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​3.​1

Patient/Study Only Query/Retrieve Information Model - FIND (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​3.​2

Patient/Study Only Query/Retrieve Information Model - MOVE (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​3.​3

Patient/Study Only Query/Retrieve Information Model - GET (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​4.​2

Composite Instance Root Retrieve - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​4.​3

Composite Instance Root Retrieve - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​5.​3

Composite Instance Retrieve Without Bulk Data - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.1

Defined Procedure Protocol Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.2

Defined Procedure Protocol Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.3

Defined Procedure Protocol Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​31

Modality Worklist Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​32

General Purpose Worklist Management Meta SOP Class (Retired)

Meta SOP Class

PS3.4

1.2.840.10008.5.1.4.​32.​1

General Purpose Worklist Information Model - FIND (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.​32.​2

General Purpose Scheduled Procedure Step SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.​32.​3

General Purpose Performed Procedure Step SOP Class (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​33

Instance Availability Notification SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​1

RT Beams Delivery Instruction Storage - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​2

RT Conventional Machine Verification - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​3

RT Ion Machine Verification - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​4

Unified Worklist and Procedure Step Service Class - Trial (Retired)

Service Class

PS3.4

1.2.840.10008.5.1.4.34.​4.​1

Unified Procedure Step - Push SOP Class - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​4.​2

Unified Procedure Step - Watch SOP Class - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​4.​3

Unified Procedure Step - Pull SOP Class - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​4.​4

Unified Procedure Step - Event SOP Class - Trial (Retired)

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​5

UPS Global Subscription SOP Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.​34.​5.​1

UPS Filtered Global Subscription SOP Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.​34.​6

Unified Worklist and Procedure Step Service Class

Service Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​1

Unified Procedure Step - Push SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​2

Unified Procedure Step - Watch SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​3

Unified Procedure Step - Pull SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​4

Unified Procedure Step - Event SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​7

RT Beams Delivery Instruction Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​8

RT Conventional Machine Verification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​9

RT Ion Machine Verification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​10

RT Brachy Application Setup Delivery Instruction Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​1

General Relevant Patient Information Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​2

Breast Imaging Relevant Patient Information Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​3

Cardiac Relevant Patient Information Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​1

Hanging Protocol Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​2

Hanging Protocol Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​3

Hanging Protocol Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​4

Hanging Protocol Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​1

Color Palette Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​2

Color Palette Query/Retrieve Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​3

Color Palette Query/Retrieve Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​4

Color Palette Query/Retrieve Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​41

Product Characteristics Query SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​42

Substance Approval Query SOP Class

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​1

Generic Implant Template Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​2

Generic Implant Template Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​3

Generic Implant Template Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​4

Generic Implant Template Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​1

Implant Assembly Template Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​2

Implant Assembly Template Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​3

Implant Assembly Template Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​4

Implant Assembly Template Information Model - GET

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​1

Implant Template Group Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​2

Implant Template Group Information Model - FIND

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​3

Implant Template Group Information Model - MOVE

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​4

Implant Template Group Information Model - GET

SOP Class

PS3.4

1.2.840.10008.7.​1.​1

Native DICOM Model

Application Hosting Model

PS3.19

1.2.840.10008.7.​1.​2

Abstract Multi-Dimensional Image Model

Application Hosting Model

PS3.19

1.2.840.10008.8.​1.​1

DICOM Content Mapping Resource

Mapping Resource

PS3.16

1.2.840.10008.15.0.​3.​1

dicom​Device​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​2

dicom​Description

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​3

dicom​Manufacturer

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​4

dicom​Manufacturer​Model​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​5

dicom​Software​Version

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​6

dicom​Vendor​Data

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​7

dicomAE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​8

dicom​Network​Connection​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​9

dicom​Application​Cluster

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​10

dicom​Association​Initiator

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​11

dicom​Association​Acceptor

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​12

dicom​Hostname

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​13

dicom​Port

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​14

dicomSOP​Class

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​15

dicom​Transfer​Role

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​16

dicom​Transfer​Syntax

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​17

dicom​Primary​Device​Type

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​18

dicom​Related​Device​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​19

dicom​Preferred​CalledAE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​20

dicomTLS​Cyphersuite

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​21

dicom​Authorized​Node​Certificate​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​22

dicom​This​Node​Certificate​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​23

dicom​Installed

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​24

dicom​Station​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​25

dicom​Device​Serial​Number

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​26

dicom​Institution​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​27

dicom​Institution​Address

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​28

dicom​Institution​Department​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​29

dicom​Issuer​OfPatientID

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​30

dicom​Preferred​CallingAE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​31

dicom​Supported​Character​Set

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​1

dicom​Configuration​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​2

dicom​Devices​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​3

dicom​UniqueAE​Titles​Registry​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​4

dicom​Device

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​5

dicom​NetworkAE

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​6

dicom​Network​Connection

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​7

dicom​UniqueAE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​8

dicom​Transfer​Capability

LDAP OID

PS3.15

1.2.840.10008.15.​1.​1

Universal Coordinated Time

Synchronization Frame of Reference

PS3.3


Table A-2. Well-known Frames of Reference

UID Value

UID Name

Normative Reference

1.2.840.10008.1.4.​1.​1

Talairach Brain Atlas Frame of Reference

Talairach J. and Tournoux P. Co-Planar stereotactic atlas of the human brain. Stutgart: Georg Thieme Verlag, 1988.

1.2.840.10008.1.4.​1.​2

SPM2 T1 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/T1.mnc

1.2.840.10008.1.4.​1.​3

SPM2 T2 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/T2.mnc

1.2.840.10008.1.4.​1.​4

SPM2 PD Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/PD.mnc

1.2.840.10008.1.4.​1.​5

SPM2 EPI Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/EPI.mnc

1.2.840.10008.1.4.​1.​6

SPM2 FIL T1 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/filT1.mnc

1.2.840.10008.1.4.​1.​7

SPM2 PET Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/PET.mnc

1.2.840.10008.1.4.​1.​8

SPM2 TRANSM Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/Transm.mnc

1.2.840.10008.1.4.​1.​9

SPM2 SPECT Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/templates/SPECT.mnc

1.2.840.10008.1.4.​1.​10

SPM2 GRAY Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/apriori/gray.mnc

1.2.840.10008.1.4.​1.​11

SPM2 WHITE Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/apriori/white.mnc

1.2.840.10008.1.4.​1.​12

SPM2 CSF Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/apriori/csf.mnc

1.2.840.10008.1.4.​1.​13

SPM2 BRAINMASK Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/apriori/brainmask.mnc

1.2.840.10008.1.4.​1.​14

SPM2 AVG305T1 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg305T1.mnc

1.2.840.10008.1.4.​1.​15

SPM2 AVG152T1 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T1.mnc

1.2.840.10008.1.4.​1.​16

SPM2 AVG152T2 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T2.mnc

1.2.840.10008.1.4.​1.​17

SPM2 AVG152PD Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152PD.mnc

1.2.840.10008.1.4.​1.​18

SPM2 SINGLESUBJT1 Frame of Reference

http://​github.com/​spm/​spm2/​blob/​master/canonical/single_subj_T1.mnc

1.2.840.10008.1.4.​2.​1

ICBM 452 T1 Frame of Reference

ICBM452 T1 Atlas

1.2.840.10008.1.4.​2.​2

ICBM Single Subject MRI Frame of Reference

ICBM Single Subject MRI Anatomical Template


SPM2 (Statistical Parametric Mapping) templates are available at http://github.com/spm/spm2/, and they are described at https://github.com/spm/spm2/blob/master/spm_templates.man.

ICBM templates are available at http://www.loni.ucla.edu/ICBM/ICBM_ICBMAtlases.html.

Table A-3. Context Group UID Values

Context UID

Context Identifier

Context Group Name

1.2.840.10008.6.​1.​1

CID 2

Anatomic Modifier

1.2.840.10008.6.​1.​2

CID 4

Anatomic Region

1.2.840.10008.6.​1.​3

CID 5

Transducer Approach

1.2.840.10008.6.​1.​4

CID 6

Transducer Orientation

1.2.840.10008.6.​1.​5

CID 7

Ultrasound Beam Path

1.2.840.10008.6.​1.​6

CID 8

Angiographic Interventional Devices

1.2.840.10008.6.​1.​7

CID 9

Image Guided Therapeutic Procedures

1.2.840.10008.6.​1.​8

CID 10

Interventional Drug

1.2.840.10008.6.​1.​9

CID 11

Route of Administration

1.2.840.10008.6.​1.​10

CID 12

Radiographic Contrast Agent

1.2.840.10008.6.​1.​11

CID 13

Radiographic Contrast Agent Ingredient

1.2.840.10008.6.​1.​12

CID 18

Isotopes in Radiopharmaceuticals

1.2.840.10008.6.​1.​13

CID 19

Patient Orientation

1.2.840.10008.6.​1.​14

CID 20

Patient Orientation Modifier

1.2.840.10008.6.​1.​15

CID 21

Patient Equipment Relationship

1.2.840.10008.6.​1.​16

CID 23

Cranio-Caudad Angulation

1.2.840.10008.6.​1.​17

CID 25

Radiopharmaceuticals

1.2.840.10008.6.​1.​18

CID 26

Nuclear Medicine Projections

1.2.840.10008.6.​1.​19

CID 29

Acquisition Modality

1.2.840.10008.6.​1.​20

CID 30

DICOM Devices

1.2.840.10008.6.​1.​21

CID 31

Abstract Priors

1.2.840.10008.6.​1.​22

CID 42

Numeric Value Qualifier

1.2.840.10008.6.​1.​23

CID 82

Units of Measurement

1.2.840.10008.6.​1.​24

CID 83

Units for Real World Value Mapping

1.2.840.10008.6.​1.​25

CID 220

Level of Significance

1.2.840.10008.6.​1.​26

CID 221

Measurement Range Concepts

1.2.840.10008.6.​1.​27

CID 222

Normality Codes

1.2.840.10008.6.​1.​28

CID 223

Normal Range Values

1.2.840.10008.6.​1.​29

CID 224

Selection Method

1.2.840.10008.6.​1.​30

CID 225

Measurement Uncertainty Concepts

1.2.840.10008.6.​1.​31

CID 226

Population Statistical Descriptors

1.2.840.10008.6.​1.​32

CID 227

Sample Statistical Descriptors

1.2.840.10008.6.​1.​33

CID 228

Equation or Table

1.2.840.10008.6.​1.​34

CID 230

Yes-No

1.2.840.10008.6.​1.​35

CID 240

Present-Absent

1.2.840.10008.6.​1.​36

CID 242

Normal-Abnormal

1.2.840.10008.6.​1.​37

CID 244

Laterality

1.2.840.10008.6.​1.​38

CID 250

Positive-Negative

1.2.840.10008.6.​1.​39

CID 251

Severity of Complication

1.2.840.10008.6.​1.​40

CID 270

Observer Type

1.2.840.10008.6.​1.​41

CID 271

Observation Subject Class

1.2.840.10008.6.​1.​42

CID 3000

Audio Channel Source

1.2.840.10008.6.​1.​43

CID 3001

ECG Leads

1.2.840.10008.6.​1.​44

CID 3003

Hemodynamic Waveform Sources

1.2.840.10008.6.​1.​45

CID 3010

Cardiovascular Anatomic Locations

1.2.840.10008.6.​1.​46

CID 3011

Electrophysiology Anatomic Locations

1.2.840.10008.6.​1.​47

CID 3014

Coronary Artery Segments

1.2.840.10008.6.​1.​48

CID 3015

Coronary Arteries

1.2.840.10008.6.​1.​49

CID 3019

Cardiovascular Anatomic Location Modifiers

1.2.840.10008.6.​1.​50

CID 3082

Cardiology Units of Measurement (Retired)

1.2.840.10008.6.​1.​51

CID 3090

Time Synchronization Channel Types

1.2.840.10008.6.​1.​52

CID 3101

Cardiac Procedural State Values

1.2.840.10008.6.​1.​53

CID 3240

Electrophysiology Measurement Functions and Techniques

1.2.840.10008.6.​1.​54

CID 3241

Hemodynamic Measurement Techniques

1.2.840.10008.6.​1.​55

CID 3250

Catheterization Procedure Phase

1.2.840.10008.6.​1.​56

CID 3254

Electrophysiology Procedure Phase

1.2.840.10008.6.​1.​57

CID 3261

Stress Protocols

1.2.840.10008.6.​1.​58

CID 3262

ECG Patient State Values

1.2.840.10008.6.​1.​59

CID 3263

Electrode Placement Values

1.2.840.10008.6.​1.​60

CID 3264

XYZ Electrode Placement Values (Retired)

1.2.840.10008.6.​1.​61

CID 3271

Hemodynamic Physiological Challenges

1.2.840.10008.6.​1.​62

CID 3335

ECG Annotations

1.2.840.10008.6.​1.​63

CID 3337

Hemodynamic Annotations

1.2.840.10008.6.​1.​64

CID 3339

Electrophysiology Annotations

1.2.840.10008.6.​1.​65

CID 3400

Procedure Log Titles

1.2.840.10008.6.​1.​66

CID 3401

Types of Log Notes

1.2.840.10008.6.​1.​67

CID 3402

Patient Status and Events

1.2.840.10008.6.​1.​68

CID 3403

Percutaneous Entry

1.2.840.10008.6.​1.​69

CID 3404

Staff Actions

1.2.840.10008.6.​1.​70

CID 3405

Procedure Action Values

1.2.840.10008.6.​1.​71

CID 3406

Non-coronary Transcatheter Interventions

1.2.840.10008.6.​1.​72

CID 3407

Purpose of Reference to Object

1.2.840.10008.6.​1.​73

CID 3408

Actions With Consumables

1.2.840.10008.6.​1.​74

CID 3409

Administration of Drugs/Contrast

1.2.840.10008.6.​1.​75

CID 3410

Numeric Parameters of Drugs/Contrast

1.2.840.10008.6.​1.​76

CID 3411

Intracoronary Devices

1.2.840.10008.6.​1.​77

CID 3412

Intervention Actions and Status

1.2.840.10008.6.​1.​78

CID 3413

Adverse Outcomes

1.2.840.10008.6.​1.​79

CID 3414

Procedure Urgency

1.2.840.10008.6.​1.​80

CID 3415

Cardiac Rhythms

1.2.840.10008.6.​1.​81

CID 3416

Respiration Rhythms

1.2.840.10008.6.​1.​82

CID 3418

Lesion Risk

1.2.840.10008.6.​1.​83

CID 3419

Findings Titles

1.2.840.10008.6.​1.​84

CID 3421

Procedure Action

1.2.840.10008.6.​1.​85

CID 3422

Device Use Actions

1.2.840.10008.6.​1.​86

CID 3423

Numeric Device Characteristics

1.2.840.10008.6.​1.​87

CID 3425

Intervention Parameters

1.2.840.10008.6.​1.​88

CID 3426

Consumables Parameters

1.2.840.10008.6.​1.​89

CID 3427

Equipment Events

1.2.840.10008.6.​1.​90

CID 3428

Imaging Procedures

1.2.840.10008.6.​1.​91

CID 3429

Catheterization Devices

1.2.840.10008.6.​1.​92

CID 3430

DateTime Qualifiers

1.2.840.10008.6.​1.​93

CID 3440

Peripheral Pulse Locations

1.2.840.10008.6.​1.​94

CID 3441

Patient Assessments

1.2.840.10008.6.​1.​95

CID 3442

Peripheral Pulse Methods

1.2.840.10008.6.​1.​96

CID 3446

Skin Condition

1.2.840.10008.6.​1.​97

CID 3448

Airway Assessment

1.2.840.10008.6.​1.​98

CID 3451

Calibration Objects

1.2.840.10008.6.​1.​99

CID 3452

Calibration Methods

1.2.840.10008.6.​1.​100

CID 3453

Cardiac Volume Methods

1.2.840.10008.6.​1.​101

CID 3455

Index Methods

1.2.840.10008.6.​1.​102

CID 3456

Sub-segment Methods

1.2.840.10008.6.​1.​103

CID 3458

Contour Realignment

1.2.840.10008.6.​1.​104

CID 3460

Circumferential Extent

1.2.840.10008.6.​1.​105

CID 3461

Regional Extent

1.2.840.10008.6.​1.​106

CID 3462

Chamber Identification

1.2.840.10008.6.​1.​107

CID 3465

QA Reference Methods

1.2.840.10008.6.​1.​108

CID 3466

Plane Identification

1.2.840.10008.6.​1.​109

CID 3467

Ejection Fraction

1.2.840.10008.6.​1.​110

CID 3468

ED Volume

1.2.840.10008.6.​1.​111

CID 3469

ES Volume

1.2.840.10008.6.​1.​112

CID 3470

Vessel Lumen Cross-sectional Area Calculation Methods

1.2.840.10008.6.​1.​113

CID 3471

Estimated Volumes

1.2.840.10008.6.​1.​114

CID 3472

Cardiac Contraction Phase

1.2.840.10008.6.​1.​115

CID 3480

IVUS Procedure Phases

1.2.840.10008.6.​1.​116

CID 3481

IVUS Distance Measurements

1.2.840.10008.6.​1.​117

CID 3482

IVUS Area Measurements

1.2.840.10008.6.​1.​118

CID 3483

IVUS Longitudinal Measurements

1.2.840.10008.6.​1.​119

CID 3484

IVUS Indices and Ratios

1.2.840.10008.6.​1.​120

CID 3485

IVUS Volume Measurements

1.2.840.10008.6.​1.​121

CID 3486

Vascular Measurement Sites

1.2.840.10008.6.​1.​122

CID 3487

Intravascular Volumetric Regions

1.2.840.10008.6.​1.​123

CID 3488

Min/Max/Mean

1.2.840.10008.6.​1.​124

CID 3489

Calcium Distribution

1.2.840.10008.6.​1.​125

CID 3491

IVUS Lesion Morphologies

1.2.840.10008.6.​1.​126

CID 3492

Vascular Dissection Classifications

1.2.840.10008.6.​1.​127

CID 3493

IVUS Relative Stenosis Severities

1.2.840.10008.6.​1.​128

CID 3494

IVUS Non Morphological Findings

1.2.840.10008.6.​1.​129

CID 3495

IVUS Plaque Composition

1.2.840.10008.6.​1.​130

CID 3496

IVUS Fiducial Points

1.2.840.10008.6.​1.​131

CID 3497

IVUS Arterial Morphology

1.2.840.10008.6.​1.​132

CID 3500

Pressure Units

1.2.840.10008.6.​1.​133

CID 3502

Hemodynamic Resistance Units

1.2.840.10008.6.​1.​134

CID 3503

Indexed Hemodynamic Resistance Units

1.2.840.10008.6.​1.​135

CID 3510

Catheter Size Units

1.2.840.10008.6.​1.​136

CID 3515

Specimen Collection

1.2.840.10008.6.​1.​137

CID 3520

Blood Source Type

1.2.840.10008.6.​1.​138

CID 3524

Blood Gas Pressures

1.2.840.10008.6.​1.​139

CID 3525

Blood Gas Content

1.2.840.10008.6.​1.​140

CID 3526

Blood Gas Saturation

1.2.840.10008.6.​1.​141

CID 3527

Blood Base Excess

1.2.840.10008.6.​1.​142

CID 3528

Blood pH

1.2.840.10008.6.​1.​143

CID 3529

Arterial / Venous Content

1.2.840.10008.6.​1.​144

CID 3530

Oxygen Administration Actions

1.2.840.10008.6.​1.​145

CID 3531

Oxygen Administration

1.2.840.10008.6.​1.​146

CID 3550

Circulatory Support Actions

1.2.840.10008.6.​1.​147

CID 3551

Ventilation Actions

1.2.840.10008.6.​1.​148

CID 3552

Pacing Actions

1.2.840.10008.6.​1.​149

CID 3553

Circulatory Support

1.2.840.10008.6.​1.​150

CID 3554

Ventilation

1.2.840.10008.6.​1.​151

CID 3555

Pacing

1.2.840.10008.6.​1.​152

CID 3560

Blood Pressure Methods

1.2.840.10008.6.​1.​153

CID 3600

Relative Times

1.2.840.10008.6.​1.​154

CID 3602

Hemodynamic Patient State

1.2.840.10008.6.​1.​155

CID 3604

Arterial Lesion Locations

1.2.840.10008.6.​1.​156

CID 3606

Arterial Source Locations

1.2.840.10008.6.​1.​157

CID 3607

Venous Source Locations

1.2.840.10008.6.​1.​158

CID 3608

Atrial Source Locations

1.2.840.10008.6.​1.​159

CID 3609

Ventricular Source Locations

1.2.840.10008.6.​1.​160

CID 3610

Gradient Source Locations

1.2.840.10008.6.​1.​161

CID 3611

Pressure Measurements

1.2.840.10008.6.​1.​162

CID 3612

Blood Velocity Measurements

1.2.840.10008.6.​1.​163

CID 3613

Hemodynamic Time Measurements

1.2.840.10008.6.​1.​164

CID 3614

Valve Areas, Non-mitral

1.2.840.10008.6.​1.​165

CID 3615

Valve Areas

1.2.840.10008.6.​1.​166

CID 3616

Hemodynamic Period Measurements

1.2.840.10008.6.​1.​167

CID 3617

Valve Flows

1.2.840.10008.6.​1.​168

CID 3618

Hemodynamic Flows

1.2.840.10008.6.​1.​169

CID 3619

Hemodynamic Resistance Measurements

1.2.840.10008.6.​1.​170

CID 3620

Hemodynamic Ratios

1.2.840.10008.6.​1.​171

CID 3621

Fractional Flow Reserve

1.2.840.10008.6.​1.​172

CID 3627

Measurement Type

1.2.840.10008.6.​1.​173

CID 3628

Cardiac Output Methods

1.2.840.10008.6.​1.​174

CID 3629

Procedure Intent

1.2.840.10008.6.​1.​175

CID 3630

Cardiovascular Anatomic Locations

1.2.840.10008.6.​1.​176

CID 3640

Hypertension

1.2.840.10008.6.​1.​177

CID 3641

Hemodynamic Assessments

1.2.840.10008.6.​1.​178

CID 3642

Degree Findings

1.2.840.10008.6.​1.​179

CID 3651

Hemodynamic Measurement Phase

1.2.840.10008.6.​1.​180

CID 3663

Body Surface Area Equations

1.2.840.10008.6.​1.​181

CID 3664

Oxygen Consumption Equations and Tables

1.2.840.10008.6.​1.​182

CID 3666

P50 Equations

1.2.840.10008.6.​1.​183

CID 3667

Framingham Scores

1.2.840.10008.6.​1.​184

CID 3668

Framingham Tables

1.2.840.10008.6.​1.​185

CID 3670

ECG Procedure Types

1.2.840.10008.6.​1.​186

CID 3671

Reason for ECG Exam

1.2.840.10008.6.​1.​187

CID 3672

Pacemakers

1.2.840.10008.6.​1.​188

CID 3673

Diagnosis (Retired)

1.2.840.10008.6.​1.​189

CID 3675

Other Filters (Retired)

1.2.840.10008.6.​1.​190

CID 3676

Lead Measurement Technique

1.2.840.10008.6.​1.​191

CID 3677

Summary Codes ECG

1.2.840.10008.6.​1.​192

CID 3678

QT Correction Algorithms

1.2.840.10008.6.​1.​193

CID 3679

ECG Morphology Descriptions (Retired)

1.2.840.10008.6.​1.​194

CID 3680

ECG Lead Noise Descriptions

1.2.840.10008.6.​1.​195

CID 3681

ECG Lead Noise Modifiers (Retired)

1.2.840.10008.6.​1.​196

CID 3682

Probability (Retired)

1.2.840.10008.6.​1.​197

CID 3683

Modifiers (Retired)

1.2.840.10008.6.​1.​198

CID 3684

Trend (Retired)

1.2.840.10008.6.​1.​199

CID 3685

Conjunctive Terms (Retired)

1.2.840.10008.6.​1.​200

CID 3686

ECG Interpretive Statements (Retired)

1.2.840.10008.6.​1.​201

CID 3687

Electrophysiology Waveform Durations

1.2.840.10008.6.​1.​202

CID 3688

Electrophysiology Waveform Voltages

1.2.840.10008.6.​1.​203

CID 3700

Cath Diagnosis

1.2.840.10008.6.​1.​204

CID 3701

Cardiac Valves and Tracts

1.2.840.10008.6.​1.​205

CID 3703

Wall Motion

1.2.840.10008.6.​1.​206

CID 3704

Myocardium Wall Morphology Findings

1.2.840.10008.6.​1.​207

CID 3705

Chamber Size

1.2.840.10008.6.​1.​208

CID 3706

Overall Contractility

1.2.840.10008.6.​1.​209

CID 3707

VSD Description

1.2.840.10008.6.​1.​210

CID 3709

Aortic Root Description

1.2.840.10008.6.​1.​211

CID 3710

Coronary Dominance

1.2.840.10008.6.​1.​212

CID 3711

Valvular Abnormalities

1.2.840.10008.6.​1.​213

CID 3712

Vessel Descriptors

1.2.840.10008.6.​1.​214

CID 3713

TIMI Flow Characteristics

1.2.840.10008.6.​1.​215

CID 3714

Thrombus

1.2.840.10008.6.​1.​216

CID 3715

Lesion Margin

1.2.840.10008.6.​1.​217

CID 3716

Severity

1.2.840.10008.6.​1.​218

CID 3717

Myocardial Wall Segments

1.2.840.10008.6.​1.​219

CID 3718

Myocardial Wall Segments in Projection

1.2.840.10008.6.​1.​220

CID 3719

Canadian Clinical Classification

1.2.840.10008.6.​1.​221

CID 3720

Cardiac History Dates (Retired)

1.2.840.10008.6.​1.​222

CID 3721

Cardiovascular Surgeries

1.2.840.10008.6.​1.​223

CID 3722

Diabetic Therapy

1.2.840.10008.6.​1.​224

CID 3723

MI Types

1.2.840.10008.6.​1.​225

CID 3724

Smoking History

1.2.840.10008.6.​1.​226

CID 3726

Indications for Coronary Intervention

1.2.840.10008.6.​1.​227

CID 3727

Indications for Catheterization

1.2.840.10008.6.​1.​228

CID 3728

Cath Findings

1.2.840.10008.6.​1.​229

CID 3729

Admission Status

1.2.840.10008.6.​1.​230

CID 3730

Insurance Payor

1.2.840.10008.6.​1.​231

CID 3733

Primary Cause of Death

1.2.840.10008.6.​1.​232

CID 3735

Acute Coronary Syndrome Time Period

1.2.840.10008.6.​1.​233

CID 3736

NYHA Classification

1.2.840.10008.6.​1.​234

CID 3737

Non-invasive Test - Ischemia

1.2.840.10008.6.​1.​235

CID 3738

Pre-Cath Angina Type

1.2.840.10008.6.​1.​236

CID 3739

Cath Procedure Type

1.2.840.10008.6.​1.​237

CID 3740

Thrombolytic Administration

1.2.840.10008.6.​1.​238

CID 3741

Medication Administration, Lab Visit

1.2.840.10008.6.​1.​239

CID 3742

Medication Administration, PCI

1.2.840.10008.6.​1.​240

CID 3743

Clopidogrel/Ticlopidine Administration

1.2.840.10008.6.​1.​241

CID 3744

EF Testing Method

1.2.840.10008.6.​1.​242

CID 3745

Calculation Method

1.2.840.10008.6.​1.​243

CID 3746

Percutaneous Entry Site

1.2.840.10008.6.​1.​244

CID 3747

Percutaneous Closure

1.2.840.10008.6.​1.​245

CID 3748

Angiographic EF Testing Method

1.2.840.10008.6.​1.​246

CID 3749

PCI Procedure Result

1.2.840.10008.6.​1.​247

CID 3750

Previously Dilated Lesion

1.2.840.10008.6.​1.​248

CID 3752

Guidewire Crossing

1.2.840.10008.6.​1.​249

CID 3754

Vascular Complications

1.2.840.10008.6.​1.​250

CID 3755

Cath Complications

1.2.840.10008.6.​1.​251

CID 3756

Cardiac Patient Risk Factors

1.2.840.10008.6.​1.​252

CID 3757

Cardiac Diagnostic Procedures

1.2.840.10008.6.​1.​253

CID 3758

Cardiovascular Family History

1.2.840.10008.6.​1.​254

CID 3760

Hypertension Therapy

1.2.840.10008.6.​1.​255

CID 3761

Antilipemic Agents

1.2.840.10008.6.​1.​256

CID 3762

Antiarrhythmic Agents

1.2.840.10008.6.​1.​257

CID 3764

Myocardial Infarction Therapies

1.2.840.10008.6.​1.​258

CID 3769

Concern Types

1.2.840.10008.6.​1.​259

CID 3770

Problem Status

1.2.840.10008.6.​1.​260

CID 3772

Health Status

1.2.840.10008.6.​1.​261

CID 3773

Use Status

1.2.840.10008.6.​1.​262

CID 3774

Social History

1.2.840.10008.6.​1.​263

CID 3777

Implanted Devices

1.2.840.10008.6.​1.​264

CID 3802

Plaque Structures

1.2.840.10008.6.​1.​265

CID 3804

Stenosis Measurement Methods

1.2.840.10008.6.​1.​266

CID 3805

Stenosis Types

1.2.840.10008.6.​1.​267

CID 3806

Stenosis Shape

1.2.840.10008.6.​1.​268

CID 3807

Volume Measurement Methods

1.2.840.10008.6.​1.​269

CID 3808

Aneurysm Types

1.2.840.10008.6.​1.​270

CID 3809

Associated Conditions

1.2.840.10008.6.​1.​271

CID 3810

Vascular Morphology

1.2.840.10008.6.​1.​272

CID 3813

Stent Findings

1.2.840.10008.6.​1.​273

CID 3814

Stent Composition

1.2.840.10008.6.​1.​274

CID 3815

Source of Vascular Finding

1.2.840.10008.6.​1.​275

CID 3817

Vascular Sclerosis Types

1.2.840.10008.6.​1.​276

CID 3820

Non-invasive Vascular Procedures

1.2.840.10008.6.​1.​277

CID 3821

Papillary Muscle Included/Excluded

1.2.840.10008.6.​1.​278

CID 3823

Respiratory Status

1.2.840.10008.6.​1.​279

CID 3826

Heart Rhythm

1.2.840.10008.6.​1.​280

CID 3827

Vessel Segments

1.2.840.10008.6.​1.​281

CID 3829

Pulmonary Arteries

1.2.840.10008.6.​1.​282

CID 3831

Stenosis Length

1.2.840.10008.6.​1.​283

CID 3832

Stenosis Grade

1.2.840.10008.6.​1.​284

CID 3833

Cardiac Ejection Fraction

1.2.840.10008.6.​1.​285

CID 3835

Cardiac Volume Measurements

1.2.840.10008.6.​1.​286

CID 3836

Time-based Perfusion Measurements

1.2.840.10008.6.​1.​287

CID 3837

Fiducial Feature

1.2.840.10008.6.​1.​288

CID 3838

Diameter Derivation

1.2.840.10008.6.​1.​289

CID 3839

Coronary Veins

1.2.840.10008.6.​1.​290

CID 3840

Pulmonary Veins

1.2.840.10008.6.​1.​291

CID 3843

Myocardial Subsegment

1.2.840.10008.6.​1.​292

CID 4005

Partial View Section for Mammography

1.2.840.10008.6.​1.​293

CID 4009

DX Anatomy Imaged

1.2.840.10008.6.​1.​294

CID 4010

DX View

1.2.840.10008.6.​1.​295

CID 4011

DX View Modifier

1.2.840.10008.6.​1.​296

CID 4012

Projection Eponymous Name

1.2.840.10008.6.​1.​297

CID 4013

Anatomic Region for Mammography

1.2.840.10008.6.​1.​298

CID 4014

View for Mammography

1.2.840.10008.6.​1.​299

CID 4015

View Modifier for Mammography

1.2.840.10008.6.​1.​300

CID 4016

Anatomic Region for Intra-oral Radiography

1.2.840.10008.6.​1.​301

CID 4017

Anatomic Region Modifier for Intra-oral Radiography

1.2.840.10008.6.​1.​302

CID 4018

Primary Anatomic Structure for Intra-oral Radiography (Permanent Dentition - Designation of Teeth)

1.2.840.10008.6.​1.​303

CID 4019

Primary Anatomic Structure for Intra-oral Radiography (Deciduous Dentition - Designation of Teeth)

1.2.840.10008.6.​1.​304

CID 4020

PET Radionuclide

1.2.840.10008.6.​1.​305

CID 4021

PET Radiopharmaceutical

1.2.840.10008.6.​1.​306

CID 4028

Craniofacial Anatomic Regions

1.2.840.10008.6.​1.​307

CID 4030

CT, MR and PET Anatomy Imaged

1.2.840.10008.6.​1.​308

CID 4031

Common Anatomic Regions

1.2.840.10008.6.​1.​309

CID 4032

MR Spectroscopy Metabolites

1.2.840.10008.6.​1.​310

CID 4033

MR Proton Spectroscopy Metabolites

1.2.840.10008.6.​1.​311

CID 4040

Endoscopy Anatomic Regions

1.2.840.10008.6.​1.​312

CID 4042

XA/XRF Anatomy Imaged

1.2.840.10008.6.​1.​313

CID 4050

Drug or Contrast Agent Characteristics

1.2.840.10008.6.​1.​314

CID 4051

General Devices

1.2.840.10008.6.​1.​315

CID 4052

Phantom Devices

1.2.840.10008.6.​1.​316

CID 4200

Ophthalmic Imaging Agent

1.2.840.10008.6.​1.​317

CID 4201

Patient Eye Movement Command

1.2.840.10008.6.​1.​318

CID 4202

Ophthalmic Photography Acquisition Device

1.2.840.10008.6.​1.​319

CID 4203

Ophthalmic Photography Illumination

1.2.840.10008.6.​1.​320

CID 4204

Ophthalmic Filter

1.2.840.10008.6.​1.​321

CID 4205

Ophthalmic Lens

1.2.840.10008.6.​1.​322

CID 4206

Ophthalmic Channel Description

1.2.840.10008.6.​1.​323

CID 4207

Ophthalmic Image Position

1.2.840.10008.6.​1.​324

CID 4208

Mydriatic Agent

1.2.840.10008.6.​1.​325

CID 4209

Ophthalmic Anatomic Structure Imaged

1.2.840.10008.6.​1.​326

CID 4210

Ophthalmic Tomography Acquisition Device

1.2.840.10008.6.​1.​327

CID 4211

Ophthalmic OCT Anatomic Structure Imaged

1.2.840.10008.6.​1.​328

CID 5000

Languages

1.2.840.10008.6.​1.​329

CID 5001

Countries

1.2.840.10008.6.​1.​330

CID 6000

Overall Breast Composition

1.2.840.10008.6.​1.​331

CID 6001

Overall Breast Composition from BI-RADS®

1.2.840.10008.6.​1.​332

CID 6002

Change Since Last Mammogram or Prior Surgery

1.2.840.10008.6.​1.​333

CID 6003

Change Since Last Mammogram or Prior Surgery from BI-RADS®

1.2.840.10008.6.​1.​334

CID 6004

Mammography Characteristics of Shape

1.2.840.10008.6.​1.​335

CID 6005

Characteristics of Shape from BI-RADS®

1.2.840.10008.6.​1.​336

CID 6006

Mammography Characteristics of Margin

1.2.840.10008.6.​1.​337

CID 6007

Characteristics of Margin from BI-RADS®

1.2.840.10008.6.​1.​338

CID 6008

Density Modifier

1.2.840.10008.6.​1.​339

CID 6009

Density Modifier from BI-RADS®

1.2.840.10008.6.​1.​340

CID 6010

Mammography Calcification Types

1.2.840.10008.6.​1.​341

CID 6011

Calcification Types from BI-RADS®

1.2.840.10008.6.​1.​342

CID 6012

Calcification Distribution Modifier

1.2.840.10008.6.​1.​343

CID 6013

Calcification Distribution Modifier from BI-RADS®

1.2.840.10008.6.​1.​344

CID 6014

Mammography Single Image Finding

1.2.840.10008.6.​1.​345

CID 6015

Single Image Finding from BI-RADS®

1.2.840.10008.6.​1.​346

CID 6016

Mammography Composite Feature

1.2.840.10008.6.​1.​347

CID 6017

Composite Feature from BI-RADS®

1.2.840.10008.6.​1.​348

CID 6018

Clockface Location or Region

1.2.840.10008.6.​1.​349

CID 6019

Clockface Location or Region from BI-RADS®

1.2.840.10008.6.​1.​350

CID 6020

Quadrant Location

1.2.840.10008.6.​1.​351

CID 6021

Quadrant Location from BI-RADS®

1.2.840.10008.6.​1.​352

CID 6022

Side

1.2.840.10008.6.​1.​353

CID 6023

Side from BI-RADS®

1.2.840.10008.6.​1.​354

CID 6024

Depth

1.2.840.10008.6.​1.​355

CID 6025

Depth from BI-RADS®

1.2.840.10008.6.​1.​356

CID 6026

Mammography Assessment

1.2.840.10008.6.​1.​357

CID 6027

Assessment from BI-RADS®

1.2.840.10008.6.​1.​358

CID 6028

Mammography Recommended Follow-up

1.2.840.10008.6.​1.​359

CID 6029

Recommended Follow-up from BI-RADS®

1.2.840.10008.6.​1.​360

CID 6030

Mammography Pathology Codes

1.2.840.10008.6.​1.​361

CID 6031

Benign Pathology Codes from BI-RADS®

1.2.840.10008.6.​1.​362

CID 6032

High Risk Lesions Pathology Codes from BI-RADS®

1.2.840.10008.6.​1.​363

CID 6033

Malignant Pathology Codes from BI-RADS®

1.2.840.10008.6.​1.​364

CID 6034

Intended Use of CAD Output

1.2.840.10008.6.​1.​365

CID 6035

Composite Feature Relations

1.2.840.10008.6.​1.​366

CID 6036

Scope of Feature

1.2.840.10008.6.​1.​367

CID 6037

Mammography Quantitative Temporal Difference Type

1.2.840.10008.6.​1.​368

CID 6038

Mammography Qualitative Temporal Difference Type

1.2.840.10008.6.​1.​369

CID 6039

Nipple Characteristic

1.2.840.10008.6.​1.​370

CID 6040

Non-lesion Object Type

1.2.840.10008.6.​1.​371

CID 6041

Mammography Image Quality Finding

1.2.840.10008.6.​1.​372

CID 6042

Status of Results

1.2.840.10008.6.​1.​373

CID 6043

Types of Mammography CAD Analysis

1.2.840.10008.6.​1.​374

CID 6044

Types of Image Quality Assessment

1.2.840.10008.6.​1.​375

CID 6045

Mammography Types of Quality Control Standard

1.2.840.10008.6.​1.​376

CID 6046

Units of Follow-up Interval

1.2.840.10008.6.​1.​377

CID 6047

CAD Processing and Findings Summary

1.2.840.10008.6.​1.​378

CID 6048

CAD Operating Point Axis Label

1.2.840.10008.6.​1.​379

CID 6050

Breast Procedure Reported

1.2.840.10008.6.​1.​380

CID 6051

Breast Procedure Reason

1.2.840.10008.6.​1.​381

CID 6052

Breast Imaging Report Section Title

1.2.840.10008.6.​1.​382

CID 6053

Breast Imaging Report Elements

1.2.840.10008.6.​1.​383

CID 6054

Breast Imaging Findings

1.2.840.10008.6.​1.​384

CID 6055

Breast Clinical Finding or Indicated Problem

1.2.840.10008.6.​1.​385

CID 6056

Associated Findings for Breast

1.2.840.10008.6.​1.​386

CID 6057

Ductography Findings for Breast

1.2.840.10008.6.​1.​387

CID 6058

Procedure Modifiers for Breast

1.2.840.10008.6.​1.​388

CID 6059

Breast Implant Types

1.2.840.10008.6.​1.​389

CID 6060

Breast Biopsy Techniques

1.2.840.10008.6.​1.​390

CID 6061

Breast Imaging Procedure Modifiers

1.2.840.10008.6.​1.​391

CID 6062

Interventional Procedure Complications

1.2.840.10008.6.​1.​392

CID 6063

Interventional Procedure Results

1.2.840.10008.6.​1.​393

CID 6064

Ultrasound Findings for Breast

1.2.840.10008.6.​1.​394

CID 6065

Instrument Approach

1.2.840.10008.6.​1.​395

CID 6066

Target Confirmation

1.2.840.10008.6.​1.​396

CID 6067

Fluid Color

1.2.840.10008.6.​1.​397

CID 6068

Tumor Stages From AJCC

1.2.840.10008.6.​1.​398

CID 6069

Nottingham Combined Histologic Grade

1.2.840.10008.6.​1.​399

CID 6070

Bloom-Richardson Histologic Grade

1.2.840.10008.6.​1.​400

CID 6071

Histologic Grading Method

1.2.840.10008.6.​1.​401

CID 6072

Breast Implant Findings

1.2.840.10008.6.​1.​402

CID 6080

Gynecological Hormones

1.2.840.10008.6.​1.​403

CID 6081

Breast Cancer Risk Factors

1.2.840.10008.6.​1.​404

CID 6082

Gynecological Procedures

1.2.840.10008.6.​1.​405

CID 6083

Procedures for Breast

1.2.840.10008.6.​1.​406

CID 6084

Mammoplasty Procedures

1.2.840.10008.6.​1.​407

CID 6085

Therapies for Breast

1.2.840.10008.6.​1.​408

CID 6086

Menopausal Phase

1.2.840.10008.6.​1.​409

CID 6087

General Risk Factors

1.2.840.10008.6.​1.​410

CID 6088

OB-GYN Maternal Risk Factors

1.2.840.10008.6.​1.​411

CID 6089

Substances

1.2.840.10008.6.​1.​412

CID 6090

Relative Usage, Exposure Amount

1.2.840.10008.6.​1.​413

CID 6091

Relative Frequency of Event Values

1.2.840.10008.6.​1.​414

CID 6092

Quantitative Concepts for Usage, Exposure

1.2.840.10008.6.​1.​415

CID 6093

Qualitative Concepts for Usage, Exposure Amount

1.2.840.10008.6.​1.​416

CID 6094

Qualitative Concepts for Usage, Exposure Frequency

1.2.840.10008.6.​1.​417

CID 6095

Numeric Properties of Procedures

1.2.840.10008.6.​1.​418

CID 6096

Pregnancy Status

1.2.840.10008.6.​1.​419

CID 6097

Side of Family

1.2.840.10008.6.​1.​420

CID 6100

Chest Component Categories

1.2.840.10008.6.​1.​421

CID 6101

Chest Finding or Feature

1.2.840.10008.6.​1.​422

CID 6102

Chest Finding or Feature Modifier

1.2.840.10008.6.​1.​423

CID 6103

Abnormal Lines Finding or Feature

1.2.840.10008.6.​1.​424

CID 6104

Abnormal Opacity Finding or Feature

1.2.840.10008.6.​1.​425

CID 6105

Abnormal Lucency Finding or Feature

1.2.840.10008.6.​1.​426

CID 6106

Abnormal Texture Finding or Feature

1.2.840.10008.6.​1.​427

CID 6107

Width Descriptor

1.2.840.10008.6.​1.​428

CID 6108

Chest Anatomic Structure Abnormal Distribution

1.2.840.10008.6.​1.​429

CID 6109

Radiographic Anatomy Finding or Feature

1.2.840.10008.6.​1.​430

CID 6110

Lung Anatomy Finding or Feature

1.2.840.10008.6.​1.​431

CID 6111

Bronchovascular Anatomy Finding or Feature

1.2.840.10008.6.​1.​432

CID 6112

Pleura Anatomy Finding or Feature

1.2.840.10008.6.​1.​433

CID 6113

Mediastinum Anatomy Finding or Feature

1.2.840.10008.6.​1.​434

CID 6114

Osseous Anatomy Finding or Feature

1.2.840.10008.6.​1.​435

CID 6115

Osseous Anatomy Modifiers

1.2.840.10008.6.​1.​436

CID 6116

Muscular Anatomy

1.2.840.10008.6.​1.​437

CID 6117

Vascular Anatomy

1.2.840.10008.6.​1.​438

CID 6118

Size Descriptor

1.2.840.10008.6.​1.​439

CID 6119

Chest Border Shape

1.2.840.10008.6.​1.​440

CID 6120

Chest Border Definition

1.2.840.10008.6.​1.​441

CID 6121

Chest Orientation Descriptor

1.2.840.10008.6.​1.​442

CID 6122

Chest Content Descriptor

1.2.840.10008.6.​1.​443

CID 6123

Chest Opacity Descriptor

1.2.840.10008.6.​1.​444

CID 6124

Location in Chest

1.2.840.10008.6.​1.​445

CID 6125

General Chest Location

1.2.840.10008.6.​1.​446

CID 6126

Location in Lung

1.2.840.10008.6.​1.​447

CID 6127

Segment Location in Lung

1.2.840.10008.6.​1.​448

CID 6128

Chest Distribution Descriptor

1.2.840.10008.6.​1.​449

CID 6129

Chest Site Involvement

1.2.840.10008.6.​1.​450

CID 6130

Severity Descriptor

1.2.840.10008.6.​1.​451

CID 6131

Chest Texture Descriptor

1.2.840.10008.6.​1.​452

CID 6132

Chest Calcification Descriptor

1.2.840.10008.6.​1.​453

CID 6133

Chest Quantitative Temporal Difference Type

1.2.840.10008.6.​1.​454

CID 6134

Chest Qualitative Temporal Difference Type

1.2.840.10008.6.​1.​455

CID 6135

Image Quality Finding

1.2.840.10008.6.​1.​456

CID 6136

Chest Types of Quality Control Standard

1.2.840.10008.6.​1.​457

CID 6137

Types of CAD Analysis

1.2.840.10008.6.​1.​458

CID 6138

Chest Non-lesion Object Type

1.2.840.10008.6.​1.​459

CID 6139

Non-lesion Modifiers

1.2.840.10008.6.​1.​460

CID 6140

Calculation Methods

1.2.840.10008.6.​1.​461

CID 6141

Attenuation Coefficient Measurements

1.2.840.10008.6.​1.​462

CID 6142

Calculated Value

1.2.840.10008.6.​1.​463

CID 6143

Lesion Response

1.2.840.10008.6.​1.​464

CID 6144

RECIST Defined Lesion Response

1.2.840.10008.6.​1.​465

CID 6145

Baseline Category

1.2.840.10008.6.​1.​466

CID 6151

Background Echotexture

1.2.840.10008.6.​1.​467

CID 6152

Orientation

1.2.840.10008.6.​1.​468

CID 6153

Lesion Boundary

1.2.840.10008.6.​1.​469

CID 6154

Echo Pattern

1.2.840.10008.6.​1.​470

CID 6155

Posterior Acoustic Features

1.2.840.10008.6.​1.​471

CID 6157

Vascularity

1.2.840.10008.6.​1.​472

CID 6158

Correlation to Other Findings

1.2.840.10008.6.​1.​473

CID 6159

Malignancy Type

1.2.840.10008.6.​1.​474

CID 6160

Breast Primary Tumor Assessment From AJCC

1.2.840.10008.6.​1.​475

CID 6161

Clinical Regional Lymph Node Assessment for Breast

1.2.840.10008.6.​1.​476

CID 6162

Assessment of Metastasis for Breast

1.2.840.10008.6.​1.​477

CID 6163

Menstrual Cycle Phase

1.2.840.10008.6.​1.​478

CID 6164

Time Intervals

1.2.840.10008.6.​1.​479

CID 6165

Breast Linear Measurements

1.2.840.10008.6.​1.​480

CID 6166

CAD Geometry Secondary Graphical Representation

1.2.840.10008.6.​1.​481

CID 7000

Diagnostic Imaging Report Document Titles

1.2.840.10008.6.​1.​482

CID 7001

Diagnostic Imaging Report Headings

1.2.840.10008.6.​1.​483

CID 7002

Diagnostic Imaging Report Elements

1.2.840.10008.6.​1.​484

CID 7003

Diagnostic Imaging Report Purposes of Reference

1.2.840.10008.6.​1.​485

CID 7004

Waveform Purposes of Reference

1.2.840.10008.6.​1.​486

CID 7005

Contributing Equipment Purposes of Reference

1.2.840.10008.6.​1.​487

CID 7006

SR Document Purposes of Reference

1.2.840.10008.6.​1.​488

CID 7007

Signature Purpose

1.2.840.10008.6.​1.​489

CID 7008

Media Import

1.2.840.10008.6.​1.​490

CID 7010

Key Object Selection Document Title

1.2.840.10008.6.​1.​491

CID 7011

Rejected for Quality Reasons

1.2.840.10008.6.​1.​492

CID 7012

Best in Set

1.2.840.10008.6.​1.​493

CID 7020

Document Titles

1.2.840.10008.6.​1.​494

CID 7100

RCS Registration Method Type

1.2.840.10008.6.​1.​495

CID 7101

Brain Atlas Fiducials

1.2.840.10008.6.​1.​496

CID 7150

Segmentation Property Categories

1.2.840.10008.6.​1.​497

CID 7151

Segmentation Property Types

1.2.840.10008.6.​1.​498

CID 7152

Cardiac Structure Segmentation Types

1.2.840.10008.6.​1.​499

CID 7153

CNS Segmentation Types

1.2.840.10008.6.​1.​500

CID 7154

Abdominal Segmentation Types

1.2.840.10008.6.​1.​501

CID 7155

Thoracic Segmentation Types

1.2.840.10008.6.​1.​502

CID 7156

Vascular Segmentation Types

1.2.840.10008.6.​1.​503

CID 7157

Device Segmentation Types

1.2.840.10008.6.​1.​504

CID 7158

Artifact Segmentation Types

1.2.840.10008.6.​1.​505

CID 7159

Lesion Segmentation Types

1.2.840.10008.6.​1.​506

CID 7160

Pelvic Organ Segmentation Types

1.2.840.10008.6.​1.​507

CID 7161

Physiology Segmentation Types

1.2.840.10008.6.​1.​508

CID 7201

Referenced Image Purposes of Reference

1.2.840.10008.6.​1.​509

CID 7202

Source Image Purposes of Reference

1.2.840.10008.6.​1.​510

CID 7203

Image Derivation

1.2.840.10008.6.​1.​511

CID 7205

Purpose of Reference to Alternate Representation

1.2.840.10008.6.​1.​512

CID 7210

Related Series Purposes of Reference

1.2.840.10008.6.​1.​513

CID 7250

Multi-Frame Subset Type

1.2.840.10008.6.​1.​514

CID 7450

Person Roles

1.2.840.10008.6.​1.​515

CID 7451

Family Member

1.2.840.10008.6.​1.​516

CID 7452

Organizational Roles

1.2.840.10008.6.​1.​517

CID 7453

Performing Roles

1.2.840.10008.6.​1.​518

CID 7454

Animal Taxonomic Rank Values

1.2.840.10008.6.​1.​519

CID 7455

Sex

1.2.840.10008.6.​1.​520

CID 7456

Units of Measure for Age

1.2.840.10008.6.​1.​521

CID 7460

Units of Linear Measurement

1.2.840.10008.6.​1.​522

CID 7461

Units of Area Measurement

1.2.840.10008.6.​1.​523

CID 7462

Units of Volume Measurement

1.2.840.10008.6.​1.​524

CID 7470

Linear Measurements

1.2.840.10008.6.​1.​525

CID 7471

Area Measurements

1.2.840.10008.6.​1.​526

CID 7472

Volume Measurements

1.2.840.10008.6.​1.​527

CID 7473

General Area Calculation Methods

1.2.840.10008.6.​1.​528

CID 7474

General Volume Calculation Methods

1.2.840.10008.6.​1.​529

CID 7480

Breed

1.2.840.10008.6.​1.​530

CID 7481

Breed Registry

1.2.840.10008.6.​1.​531

CID 9231

Workitem Definition

1.2.840.10008.6.​1.​532

CID 9232

Non-DICOM Output Types (Retired)

1.2.840.10008.6.​1.​533

CID 9300

Procedure Discontinuation Reasons

1.2.840.10008.6.​1.​534

CID 10000

Scope of Accumulation

1.2.840.10008.6.​1.​535

CID 10001

UID Types

1.2.840.10008.6.​1.​536

CID 10002

Irradiation Event Types

1.2.840.10008.6.​1.​537

CID 10003

Equipment Plane Identification

1.2.840.10008.6.​1.​538

CID 10004

Fluoro Modes

1.2.840.10008.6.​1.​539

CID 10006

X-Ray Filter Materials

1.2.840.10008.6.​1.​540

CID 10007

X-Ray Filter Types

1.2.840.10008.6.​1.​541

CID 10008

Dose Related Distance Measurements

1.2.840.10008.6.​1.​542

CID 10009

Measured/Calculated

1.2.840.10008.6.​1.​543

CID 10010

Dose Measurement Devices

1.2.840.10008.6.​1.​544

CID 10011

Effective Dose Evaluation Method

1.2.840.10008.6.​1.​545

CID 10013

CT Acquisition Type

1.2.840.10008.6.​1.​546

CID 10014

Contrast Imaging Technique

1.2.840.10008.6.​1.​547

CID 10015

CT Dose Reference Authorities

1.2.840.10008.6.​1.​548

CID 10016

Anode Target Material

1.2.840.10008.6.​1.​549

CID 10017

X-Ray Grid

1.2.840.10008.6.​1.​550

CID 12001

Ultrasound Protocol Types

1.2.840.10008.6.​1.​551

CID 12002

Ultrasound Protocol Stage Types

1.2.840.10008.6.​1.​552

CID 12003

OB-GYN Dates

1.2.840.10008.6.​1.​553

CID 12004

Fetal Biometry Ratios

1.2.840.10008.6.​1.​554

CID 12005

Fetal Biometry Measurements

1.2.840.10008.6.​1.​555

CID 12006

Fetal Long Bones Biometry Measurements

1.2.840.10008.6.​1.​556

CID 12007

Fetal Cranium

1.2.840.10008.6.​1.​557

CID 12008

OB-GYN Amniotic Sac

1.2.840.10008.6.​1.​558

CID 12009

Early Gestation Biometry Measurements

1.2.840.10008.6.​1.​559

CID 12011

Ultrasound Pelvis and Uterus

1.2.840.10008.6.​1.​560

CID 12012

OB Equations and Tables

1.2.840.10008.6.​1.​561

CID 12013

Gestational Age Equations and Tables

1.2.840.10008.6.​1.​562

CID 12014

OB Fetal Body Weight Equations and Tables

1.2.840.10008.6.​1.​563

CID 12015

Fetal Growth Equations and Tables

1.2.840.10008.6.​1.​564

CID 12016

Estimated Fetal Weight Percentile Equations and Tables

1.2.840.10008.6.​1.​565

CID 12017

Growth Distribution Rank

1.2.840.10008.6.​1.​566

CID 12018

OB-GYN Summary

1.2.840.10008.6.​1.​567

CID 12019

OB-GYN Fetus Summary

1.2.840.10008.6.​1.​568

CID 12101

Vascular Summary

1.2.840.10008.6.​1.​569

CID 12102

Temporal Periods Relating to Procedure or Therapy

1.2.840.10008.6.​1.​570

CID 12103

Vascular Ultrasound Anatomic Location

1.2.840.10008.6.​1.​571

CID 12104

Extracranial Arteries

1.2.840.10008.6.​1.​572

CID 12105

Intracranial Cerebral Vessels

1.2.840.10008.6.​1.​573

CID 12106

Intracranial Cerebral Vessels (Unilateral)

1.2.840.10008.6.​1.​574

CID 12107

Upper Extremity Arteries

1.2.840.10008.6.​1.​575

CID 12108

Upper Extremity Veins

1.2.840.10008.6.​1.​576

CID 12109

Lower Extremity Arteries

1.2.840.10008.6.​1.​577

CID 12110

Lower Extremity Veins

1.2.840.10008.6.​1.​578

CID 12111

Abdominal Arteries (Lateral)

1.2.840.10008.6.​1.​579

CID 12112

Abdominal Arteries (Unilateral)

1.2.840.10008.6.​1.​580

CID 12113

Abdominal Veins (Lateral)

1.2.840.10008.6.​1.​581

CID 12114

Abdominal Veins (Unilateral)

1.2.840.10008.6.​1.​582

CID 12115

Renal Vessels

1.2.840.10008.6.​1.​583

CID 12116

Vessel Segment Modifiers

1.2.840.10008.6.​1.​584

CID 12117

Vessel Branch Modifiers

1.2.840.10008.6.​1.​585

CID 12119

Vascular Ultrasound Property

1.2.840.10008.6.​1.​586

CID 12120

Blood Velocity Measurements by Ultrasound

1.2.840.10008.6.​1.​587

CID 12121

Vascular Indices and Ratios

1.2.840.10008.6.​1.​588

CID 12122

Other Vascular Properties

1.2.840.10008.6.​1.​589

CID 12123

Carotid Ratios

1.2.840.10008.6.​1.​590

CID 12124

Renal Ratios

1.2.840.10008.6.​1.​591

CID 12140

Pelvic Vasculature Anatomical Location

1.2.840.10008.6.​1.​592

CID 12141

Fetal Vasculature Anatomical Location

1.2.840.10008.6.​1.​593

CID 12200

Echocardiography Left Ventricle

1.2.840.10008.6.​1.​594

CID 12201

Left Ventricle Linear

1.2.840.10008.6.​1.​595

CID 12202

Left Ventricle Volume

1.2.840.10008.6.​1.​596

CID 12203

Left Ventricle Other

1.2.840.10008.6.​1.​597

CID 12204

Echocardiography Right Ventricle

1.2.840.10008.6.​1.​598

CID 12205

Echocardiography Left Atrium

1.2.840.10008.6.​1.​599

CID 12206

Echocardiography Right Atrium

1.2.840.10008.6.​1.​600

CID 12207

Echocardiography Mitral Valve

1.2.840.10008.6.​1.​601

CID 12208

Echocardiography Tricuspid Valve

1.2.840.10008.6.​1.​602

CID 12209

Echocardiography Pulmonic Valve

1.2.840.10008.6.​1.​603

CID 12210

Echocardiography Pulmonary Artery

1.2.840.10008.6.​1.​604

CID 12211

Echocardiography Aortic Valve

1.2.840.10008.6.​1.​605

CID 12212

Echocardiography Aorta

1.2.840.10008.6.​1.​606

CID 12214

Echocardiography Pulmonary Veins

1.2.840.10008.6.​1.​607

CID 12215

Echocardiography Vena Cavae

1.2.840.10008.6.​1.​608

CID 12216

Echocardiography Hepatic Veins

1.2.840.10008.6.​1.​609

CID 12217

Echocardiography Cardiac Shunt

1.2.840.10008.6.​1.​610

CID 12218

Echocardiography Congenital

1.2.840.10008.6.​1.​611

CID 12219

Pulmonary Vein Modifiers

1.2.840.10008.6.​1.​612

CID 12220

Echocardiography Common Measurements

1.2.840.10008.6.​1.​613

CID 12221

Flow Direction

1.2.840.10008.6.​1.​614

CID 12222

Orifice Flow Properties

1.2.840.10008.6.​1.​615

CID 12223

Echocardiography Stroke Volume Origin

1.2.840.10008.6.​1.​616

CID 12224

Ultrasound Image Modes

1.2.840.10008.6.​1.​617

CID 12226

Echocardiography Image View

1.2.840.10008.6.​1.​618

CID 12227

Echocardiography Measurement Method

1.2.840.10008.6.​1.​619

CID 12228

Echocardiography Volume Methods

1.2.840.10008.6.​1.​620

CID 12229

Echocardiography Area Methods

1.2.840.10008.6.​1.​621

CID 12230

Gradient Methods

1.2.840.10008.6.​1.​622

CID 12231

Volume Flow Methods

1.2.840.10008.6.​1.​623

CID 12232

Myocardium Mass Methods

1.2.840.10008.6.​1.​624

CID 12233

Cardiac Phase

1.2.840.10008.6.​1.​625

CID 12234

Respiration State

1.2.840.10008.6.​1.​626

CID 12235

Mitral Valve Anatomic Sites

1.2.840.10008.6.​1.​627

CID 12236

Echo Anatomic Sites

1.2.840.10008.6.​1.​628

CID 12237

Echocardiography Anatomic Site Modifiers

1.2.840.10008.6.​1.​629

CID 12238

Wall Motion Scoring Schemes

1.2.840.10008.6.​1.​630

CID 12239

Cardiac Output Properties

1.2.840.10008.6.​1.​631

CID 12240

Left Ventricle Area

1.2.840.10008.6.​1.​632

CID 12241

Tricuspid Valve Finding Sites

1.2.840.10008.6.​1.​633

CID 12242

Aortic Valve Finding Sites

1.2.840.10008.6.​1.​634

CID 12243

Left Ventricle Finding Sites

1.2.840.10008.6.​1.​635

CID 12244

Congenital Finding Sites

1.2.840.10008.6.​1.​636

CID 7162

Surface Processing Algorithm Families

1.2.840.10008.6.​1.​637

CID 3207

Stress Test Procedure Phases

1.2.840.10008.6.​1.​638

CID 3778

Stages

1.2.840.10008.6.​1.​735

CID 252

S-M-L Size Descriptor

1.2.840.10008.6.​1.​736

CID 3016

Major Coronary Arteries

1.2.840.10008.6.​1.​737

CID 3083

Units of Radioactivity

1.2.840.10008.6.​1.​738

CID 3102

Rest-Stress

1.2.840.10008.6.​1.​739

CID 3106

PET Cardiology Protocols

1.2.840.10008.6.​1.​740

CID 3107

PET Cardiology Radiopharmaceuticals

1.2.840.10008.6.​1.​741

CID 3108

NM/PET Procedures

1.2.840.10008.6.​1.​742

CID 3110

Nuclear Cardiology Protocols

1.2.840.10008.6.​1.​743

CID 3111

Nuclear Cardiology Radiopharmaceuticals

1.2.840.10008.6.​1.​744

CID 3112

Attenuation Correction

1.2.840.10008.6.​1.​745

CID 3113

Types of Perfusion Defects

1.2.840.10008.6.​1.​746

CID 3114

Study Quality

1.2.840.10008.6.​1.​747

CID 3115

Stress Imaging Quality Issues

1.2.840.10008.6.​1.​748

CID 3116

NM Extracardiac Findings

1.2.840.10008.6.​1.​749

CID 3117

Attenuation Correction Methods

1.2.840.10008.6.​1.​750

CID 3118

Level of Risk

1.2.840.10008.6.​1.​751

CID 3119

LV Function

1.2.840.10008.6.​1.​752

CID 3120

Perfusion Findings

1.2.840.10008.6.​1.​753

CID 3121

Perfusion Morphology

1.2.840.10008.6.​1.​754

CID 3122

Ventricular Enlargement

1.2.840.10008.6.​1.​755

CID 3200

Stress Test Procedure

1.2.840.10008.6.​1.​756

CID 3201

Indications for Stress Test

1.2.840.10008.6.​1.​757

CID 3202

Chest Pain

1.2.840.10008.6.​1.​758

CID 3203

Exerciser Device

1.2.840.10008.6.​1.​759

CID 3204

Stress Agents

1.2.840.10008.6.​1.​760

CID 3205

Indications for Pharmacological Stress Test

1.2.840.10008.6.​1.​761

CID 3206

Non-invasive Cardiac Imaging Procedures

1.2.840.10008.6.​1.​763

CID 3208

Summary Codes Exercise ECG

1.2.840.10008.6.​1.​764

CID 3209

Summary Codes Stress Imaging

1.2.840.10008.6.​1.​765

CID 3210

Speed of Response

1.2.840.10008.6.​1.​766

CID 3211

BP Response

1.2.840.10008.6.​1.​767

CID 3212

Treadmill Speed

1.2.840.10008.6.​1.​768

CID 3213

Stress Hemodynamic Findings

1.2.840.10008.6.​1.​769

CID 3215

Perfusion Finding Method

1.2.840.10008.6.​1.​770

CID 3217

Comparison Finding

1.2.840.10008.6.​1.​771

CID 3220

Stress Symptoms

1.2.840.10008.6.​1.​772

CID 3221

Stress Test Termination Reasons

1.2.840.10008.6.​1.​773

CID 3227

QTc Measurements

1.2.840.10008.6.​1.​774

CID 3228

ECG Timing Measurements

1.2.840.10008.6.​1.​775

CID 3229

ECG Axis Measurements

1.2.840.10008.6.​1.​776

CID 3230

ECG Findings

1.2.840.10008.6.​1.​777

CID 3231

ST Segment Findings

1.2.840.10008.6.​1.​778

CID 3232

ST Segment Location

1.2.840.10008.6.​1.​779

CID 3233

ST Segment Morphology

1.2.840.10008.6.​1.​780

CID 3234

Ectopic Beat Morphology

1.2.840.10008.6.​1.​781

CID 3235

Perfusion Comparison Findings

1.2.840.10008.6.​1.​782

CID 3236

Tolerance Comparison Findings

1.2.840.10008.6.​1.​783

CID 3237

Wall Motion Comparison Findings

1.2.840.10008.6.​1.​784

CID 3238

Stress Scoring Scales

1.2.840.10008.6.​1.​785

CID 3239

Perceived Exertion Scales

1.2.840.10008.6.​1.​786

CID 3463

Ventricle Identification

1.2.840.10008.6.​1.​787

CID 6200

Colon Overall Assessment

1.2.840.10008.6.​1.​788

CID 6201

Colon Finding or Feature

1.2.840.10008.6.​1.​789

CID 6202

Colon Finding or Feature Modifier

1.2.840.10008.6.​1.​790

CID 6203

Colon Non-lesion Object Type

1.2.840.10008.6.​1.​791

CID 6204

Anatomic Non-colon Findings

1.2.840.10008.6.​1.​792

CID 6205

Clockface Location for Colon

1.2.840.10008.6.​1.​793

CID 6206

Recumbent Patient Orientation for Colon

1.2.840.10008.6.​1.​794

CID 6207

Colon Quantitative Temporal Difference Type

1.2.840.10008.6.​1.​795

CID 6208

Colon Types of Quality Control Standard

1.2.840.10008.6.​1.​796

CID 6209

Colon Morphology Descriptor

1.2.840.10008.6.​1.​797

CID 6210

Location in Intestinal Tract

1.2.840.10008.6.​1.​798

CID 6211

Colon CAD Material Description

1.2.840.10008.6.​1.​799

CID 6212

Calculated Value for Colon Findings

1.2.840.10008.6.​1.​800

CID 4214

Ophthalmic Horizontal Directions

1.2.840.10008.6.​1.​801

CID 4215

Ophthalmic Vertical Directions

1.2.840.10008.6.​1.​802

CID 4216

Ophthalmic Visual Acuity Type

1.2.840.10008.6.​1.​803

CID 3004

Arterial Pulse Waveform

1.2.840.10008.6.​1.​804

CID 3005

Respiration Waveform

1.2.840.10008.6.​1.​805

CID 12030

Ultrasound Contrast/Bolus Agents

1.2.840.10008.6.​1.​806

CID 12031

Protocol Interval Events

1.2.840.10008.6.​1.​807

CID 12032

Transducer Scan Pattern

1.2.840.10008.6.​1.​808

CID 12033

Ultrasound Transducer Geometry

1.2.840.10008.6.​1.​809

CID 12034

Ultrasound Transducer Beam Steering

1.2.840.10008.6.​1.​810

CID 12035

Ultrasound Transducer Application

1.2.840.10008.6.​1.​811

CID 50

Instance Availability Status

1.2.840.10008.6.​1.​812

CID 9301

Modality PPS Discontinuation Reasons

1.2.840.10008.6.​1.​813

CID 9302

Media Import PPS Discontinuation Reasons

1.2.840.10008.6.​1.​814

CID 7482

DX Anatomy Imaged for Animals

1.2.840.10008.6.​1.​815

CID 7483

Common Anatomic Regions for Animals

1.2.840.10008.6.​1.​816

CID 7484

DX View for Animals

1.2.840.10008.6.​1.​817

CID 7030

Institutional Departments, Units and Services

1.2.840.10008.6.​1.​818

CID 7009

Purpose of Reference to Predecessor Report

1.2.840.10008.6.​1.​819

CID 4220

Visual Fixation Quality During Acquisition

1.2.840.10008.6.​1.​820

CID 4221

Visual Fixation Quality Problem

1.2.840.10008.6.​1.​821

CID 4222

Ophthalmic Macular Grid Problem

1.2.840.10008.6.​1.​822

CID 5002

Organizations

1.2.840.10008.6.​1.​823

CID 7486

Mixed Breeds

1.2.840.10008.6.​1.​824

CID 7040

Broselow-Luten Pediatric Size Categories

1.2.840.10008.6.​1.​825

CID 7042

CMDCTECC Calcium Scoring Patient Size Categories

1.2.840.10008.6.​1.​826

CID 12245

Cardiac Ultrasound Report Titles

1.2.840.10008.6.​1.​827

CID 12246

Cardiac Ultrasound Indication for Study

1.2.840.10008.6.​1.​828

CID 12247

Pediatric, Fetal and Congenital Cardiac Surgical Interventions

1.2.840.10008.6.​1.​829

CID 12248

Cardiac Ultrasound Summary Codes

1.2.840.10008.6.​1.​830

CID 12249

Cardiac Ultrasound Fetal Summary Codes

1.2.840.10008.6.​1.​831

CID 12250

Cardiac Ultrasound Common Linear Measurements

1.2.840.10008.6.​1.​832

CID 12251

Cardiac Ultrasound Linear Valve Measurements

1.2.840.10008.6.​1.​833

CID 12252

Cardiac Ultrasound Cardiac Function

1.2.840.10008.6.​1.​834

CID 12253

Cardiac Ultrasound Area Measurements

1.2.840.10008.6.​1.​835

CID 12254

Cardiac Ultrasound Hemodynamic Measurements

1.2.840.10008.6.​1.​836

CID 12255

Cardiac Ultrasound Myocardium Measurements

1.2.840.10008.6.​1.​837

1.2.840.10008.6.​1.​838

CID 12257

Cardiac Ultrasound Left Ventricle

1.2.840.10008.6.​1.​839

CID 12258

Cardiac Ultrasound Right Ventricle

1.2.840.10008.6.​1.​840

CID 12259

Cardiac Ultrasound Ventricles Measurements

1.2.840.10008.6.​1.​841

CID 12260

Cardiac Ultrasound Pulmonary Artery

1.2.840.10008.6.​1.​842

CID 12261

Cardiac Ultrasound Pulmonary Vein

1.2.840.10008.6.​1.​843

CID 12262

Cardiac Ultrasound Pulmonary Valve

1.2.840.10008.6.​1.​844

CID 12263

Cardiac Ultrasound Venous Return Pulmonary Measurements

1.2.840.10008.6.​1.​845

CID 12264

Cardiac Ultrasound Venous Return Systemic Measurements

1.2.840.10008.6.​1.​846

CID 12265

Cardiac Ultrasound Atria and Atrial Septum Measurements

1.2.840.10008.6.​1.​847

CID 12266

Cardiac Ultrasound Mitral Valve

1.2.840.10008.6.​1.​848

CID 12267

Cardiac Ultrasound Tricuspid Valve

1.2.840.10008.6.​1.​849

CID 12268

Cardiac Ultrasound Atrioventricular Valves Measurements

1.2.840.10008.6.​1.​850

CID 12269

Cardiac Ultrasound Interventricular Septum Measurements

1.2.840.10008.6.​1.​851

CID 12270

Cardiac Ultrasound Aortic Valve

1.2.840.10008.6.​1.​852

CID 12271

Cardiac Ultrasound Outflow Tracts Measurements

1.2.840.10008.6.​1.​853

CID 12272

Cardiac Ultrasound Semilunar Valves, Annulate and Sinuses Measurements

1.2.840.10008.6.​1.​854

CID 12273

Cardiac Ultrasound Aortic Sinotubular Junction

1.2.840.10008.6.​1.​855

CID 12274

Cardiac Ultrasound Aorta Measurements

1.2.840.10008.6.​1.​856

CID 12275

Cardiac Ultrasound Coronary Arteries Measurements

1.2.840.10008.6.​1.​857

CID 12276

Cardiac Ultrasound Aorto Pulmonary Connections Measurements

1.2.840.10008.6.​1.​858

CID 12277

Cardiac Ultrasound Pericardium and Pleura Measurements

1.2.840.10008.6.​1.​859

CID 12279

Cardiac Ultrasound Fetal General Measurements

1.2.840.10008.6.​1.​860

CID 12280

Cardiac Ultrasound Target Sites

1.2.840.10008.6.​1.​861

CID 12281

Cardiac Ultrasound Target Site Modifiers

1.2.840.10008.6.​1.​862

CID 12282

Cardiac Ultrasound Venous Return Systemic Finding Sites

1.2.840.10008.6.​1.​863

CID 12283

Cardiac Ultrasound Venous Return Pulmonary Finding Sites

1.2.840.10008.6.​1.​864

CID 12284

Cardiac Ultrasound Atria and Atrial Septum Finding Sites

1.2.840.10008.6.​1.​865

CID 12285

Cardiac Ultrasound Atrioventricular Valves Finding Sites

1.2.840.10008.6.​1.​866

CID 12286

Cardiac Ultrasound Interventricular Septum Finding Sites

1.2.840.10008.6.​1.​867

CID 12287

Cardiac Ultrasound Ventricles Finding Sites

1.2.840.10008.6.​1.​868

CID 12288

Cardiac Ultrasound Outflow Tracts Finding Sites

1.2.840.10008.6.​1.​869

CID 12289

Cardiac Ultrasound Semilunar Valves, Annulus and Sinuses Finding Sites

1.2.840.10008.6.​1.​870

CID 12290

Cardiac Ultrasound Pulmonary Arteries Finding Sites

1.2.840.10008.6.​1.​871

CID 12291

Cardiac Ultrasound Aorta Finding Sites

1.2.840.10008.6.​1.​872

CID 12292

Cardiac Ultrasound Coronary Arteries Finding Sites

1.2.840.10008.6.​1.​873

CID 12293

Cardiac Ultrasound Aortopulmonary Connections Finding Sites

1.2.840.10008.6.​1.​874

CID 12294

Cardiac Ultrasound Pericardium and Pleura Finding Sites

1.2.840.10008.6.​1.​876

CID 4230

Ophthalmic Ultrasound Axial Measurements Type

1.2.840.10008.6.​1.​877

CID 4231

Lens Status

1.2.840.10008.6.​1.​878

CID 4232

Vitreous Status

1.2.840.10008.6.​1.​879

CID 4233

Ophthalmic Axial Length Measurements Segment Names

1.2.840.10008.6.​1.​880

CID 4234

Refractive Surgery Types

1.2.840.10008.6.​1.​881

CID 4235

Keratometry Descriptors

1.2.840.10008.6.​1.​882

CID 4236

IOL Calculation Formula

1.2.840.10008.6.​1.​883

CID 4237

Lens Constant Type

1.2.840.10008.6.​1.​884

CID 4238

Refractive Error Types

1.2.840.10008.6.​1.​885

CID 4239

Anterior Chamber Depth Definition

1.2.840.10008.6.​1.​886

CID 4240

Ophthalmic Measurement or Calculation Data Source

1.2.840.10008.6.​1.​887

CID 4241

Ophthalmic Axial Length Selection Method

1.2.840.10008.6.​1.​888

1.2.840.10008.6.​1.​889

CID 4243

Ophthalmic Quality Metric Type

1.2.840.10008.6.​1.​890

CID 4244

Ophthalmic Agent Concentration Units

1.2.840.10008.6.​1.​891

CID 91

Functional Condition Present During Acquisition

1.2.840.10008.6.​1.​892

CID 92

Joint Position During Acquisition

1.2.840.10008.6.​1.​893

CID 93

Joint Positioning Method

1.2.840.10008.6.​1.​894

CID 94

Physical Force Applied During Acquisition

1.2.840.10008.6.​1.​895

CID 3690

ECG Control Variables Numeric

1.2.840.10008.6.​1.​896

CID 3691

ECG Control Variables Text

1.2.840.10008.6.​1.​897

CID 8120

WSI Referenced Image Purposes of Reference

1.2.840.10008.6.​1.​898

CID 8121

Microscopy Lens Type

1.2.840.10008.6.​1.​899

CID 8122

Microscopy Illuminator and Sensor Color

1.2.840.10008.6.​1.​900

CID 8123

Microscopy Illumination Method

1.2.840.10008.6.​1.​901

CID 8124

Microscopy Filter

1.2.840.10008.6.​1.​902

CID 8125

Microscopy Illuminator Type

1.2.840.10008.6.​1.​903

CID 400

Audit Event ID

1.2.840.10008.6.​1.​904

CID 401

Audit Event Type Code

1.2.840.10008.6.​1.​905

CID 402

Audit Active Participant Role ID Code

1.2.840.10008.6.​1.​906

CID 403

Security Alert Type Code

1.2.840.10008.6.​1.​907

CID 404

Audit Participant Object ID Type Code

1.2.840.10008.6.​1.​908

CID 405

Media Type Code

1.2.840.10008.6.​1.​909

CID 4250

Visual Field Static Perimetry Test Patterns

1.2.840.10008.6.​1.​910

CID 4251

Visual Field Static Perimetry Test Strategies

1.2.840.10008.6.​1.​911

CID 4252

Visual Field Static Perimetry Screening Test Modes

1.2.840.10008.6.​1.​912

CID 4253

Visual Field Static Perimetry Fixation Strategy

1.2.840.10008.6.​1.​913

CID 4254

Visual Field Static Perimetry Test Analysis Results

1.2.840.10008.6.​1.​914

CID 4255

Visual Field Illumination Color

1.2.840.10008.6.​1.​915

CID 4256

Visual Field Procedure Modifier

1.2.840.10008.6.​1.​916

CID 4257

Visual Field Global Index Name

1.2.840.10008.6.​1.​917

CID 7180

Abstract Multi-dimensional Image Model Component Semantics

1.2.840.10008.6.​1.​918

CID 7181

Abstract Multi-dimensional Image Model Component Units

1.2.840.10008.6.​1.​919

CID 7182

Abstract Multi-dimensional Image Model Dimension Semantics

1.2.840.10008.6.​1.​920

CID 7183

Abstract Multi-dimensional Image Model Dimension Units

1.2.840.10008.6.​1.​921

CID 7184

Abstract Multi-dimensional Image Model Axis Direction

1.2.840.10008.6.​1.​922

CID 7185

Abstract Multi-dimensional Image Model Axis Orientation

1.2.840.10008.6.​1.​923

CID 7186

Abstract Multi-dimensional Image Model Qualitative Dimension Sample Semantics

1.2.840.10008.6.​1.​924

CID 7320

Planning Methods

1.2.840.10008.6.​1.​925

CID 7050

De-identification Method

1.2.840.10008.6.​1.​926

CID 12118

Measurement Orientation

1.2.840.10008.6.​1.​927

CID 3689

ECG Global Waveform Durations

1.2.840.10008.6.​1.​930

CID 3692

ICDs

1.2.840.10008.6.​1.​931

CID 9241

Radiotherapy General Workitem Definition

1.2.840.10008.6.​1.​932

CID 9242

Radiotherapy Acquisition Workitem Definition

1.2.840.10008.6.​1.​933

CID 9243

Radiotherapy Registration Workitem Definition

1.2.840.10008.6.​1.​934

CID 3850

Contrast Bolus Substance

1.2.840.10008.6.​1.​935

CID 10022

Label Types

1.2.840.10008.6.​1.​936

CID 4260

Ophthalmic Mapping Units for Real World Value Mapping

1.2.840.10008.6.​1.​937

CID 4261

Ophthalmic Mapping Acquisition Method

1.2.840.10008.6.​1.​938

CID 4262

Retinal Thickness Definition

1.2.840.10008.6.​1.​939

CID 4263

Ophthalmic Thickness Map Value Type

1.2.840.10008.6.​1.​940

CID 4264

Ophthalmic Map Purposes of Reference

1.2.840.10008.6.​1.​941

CID 4265

Ophthalmic Thickness Deviation Categories

1.2.840.10008.6.​1.​942

CID 4266

Ophthalmic Anatomic Structure Reference Point

1.2.840.10008.6.​1.​943

CID 3104

Cardiac Synchronization Technique

1.2.840.10008.6.​1.​944

CID 8130

Staining Protocols

1.2.840.10008.6.​1.​945

1.2.840.10008.6.​1.​946

1.2.840.10008.6.​1.​947

CID 10023

Size Specific Dose Estimation Method for CT

1.2.840.10008.6.​1.​948

CID 8131

Pathology Imaging Protocols

1.2.840.10008.6.​1.​949

CID 8132

Magnification Selection

1.2.840.10008.6.​1.​950

CID 8133

Tissue Selection

1.2.840.10008.6.​1.​951

CID 7464

General Region of Interest Measurement Modifiers

1.2.840.10008.6.​1.​952

CID 7465

Measurements Derived From Multiple ROI Measurements

1.2.840.10008.6.​1.​953

CID 8201

Surface Scan Acquisition Types

1.2.840.10008.6.​1.​954

CID 8202

Surface Scan Mode Types

1.2.840.10008.6.​1.​956

CID 8203

Surface Scan Registration Method Types

1.2.840.10008.6.​1.​957

CID 27

Basic Cardiac Views

1.2.840.10008.6.​1.​958

CID 10033

CT Reconstruction Algorithm

1.2.840.10008.6.​1.​959

CID 10030

Detector Types

1.2.840.10008.6.​1.​960

CID 10031

CR/DR Mechanical Configuration

1.2.840.10008.6.​1.​961

CID 10032

Projection X-Ray Acquisition Device Types

1.2.840.10008.6.​1.​962

CID 7165

Abstract Segmentation Types

1.2.840.10008.6.​1.​963

CID 7166

Common Tissue Segmentation Types

1.2.840.10008.6.​1.​964

CID 7167

Peripheral Nervous System Segmentation Types

1.2.840.10008.6.​1.​965

CID 4267

Corneal Topography Mapping Units for Real World Value Mapping

1.2.840.10008.6.​1.​966

CID 4268

Corneal Topography Map Value Type

1.2.840.10008.6.​1.​967

CID 7140

Brain Structures for Volumetric Measurements

1.2.840.10008.6.​1.​968

CID 7220

RT Dose Derivation

1.2.840.10008.6.​1.​969

CID 7221

RT Dose Purpose of Reference

1.2.840.10008.6.1.970

CID 7215

Spectroscopy Purpose of Reference

1.2.840.10008.6.​1.​971

CID 9250

Scheduled Processing Parameter Concept Codes for RT Treatment

1.2.840.10008.6.1.972

CID 10040

Radiopharmaceutical Organ Dose Reference Authority

1.2.840.10008.6.1.973

CID 10041

Source of Radioisotope Activity Information

1.2.840.10008.6.1.975

CID 10043

Intravenous Extravasation Symptoms

1.2.840.10008.6.1.976

CID 10044

Radiosensitive Organs

1.2.840.10008.6.1.977

CID 10045

Radiopharmaceutical Patient State

1.2.840.10008.6.1.978

CID 10046

GFR Measurements

1.2.840.10008.6.1.979

CID 10047

GFR Measurement Methods

1.2.840.10008.6.1.980

CID 8300

Visual Evaluation Methods

1.2.840.10008.6.1.981

CID 8301

Test Pattern Codes

1.2.840.10008.6.1.982

CID 8302

Measurement Pattern Codes

1.2.840.10008.6.1.983

CID 8303

Display Device Type

1.2.840.10008.6.1.984

CID 85

SUV Units

1.2.840.10008.6.1.985

CID 4100

T1 Measurement Methods

1.2.840.10008.6.1.986

CID 4101

Tracer Kinetic Models

1.2.840.10008.6.1.987

CID 4102

Perfusion Measurement Methods

1.2.840.10008.6.1.988

CID 4103

Arterial Input Function Measurement Methods

1.2.840.10008.6.1.989

CID 4104

Bolus Arrival Time Derivation Methods

1.2.840.10008.6.1.990

CID 4105

Perfusion Analysis Methods

1.2.840.10008.6.1.991

CID 4106

Quantitative Methods used for Perfusion And Tracer Kinetic Models

1.2.840.10008.6.1.992

CID 4107

Tracer Kinetic Model Parameters

1.2.840.10008.6.1.993

CID 4108

Perfusion Model Parameters

1.2.840.10008.6.1.994

CID 4109

Model-Independent Dynamic Contrast Analysis Parameters

1.2.840.10008.6.1.995

CID 4110

Tracer Kinetic Modeling Covariates

1.2.840.10008.6.1.996

CID 4111

Contrast Characteristics

1.2.840.10008.6.1.997

CID 7021

Measurement Report Document Titles

1.2.840.10008.6.1.998

CID 100

Quantitative Diagnostic Imaging Procedures

1.2.840.10008.6.1.999

CID 7466

PET Region of Interest Measurements

1.2.840.10008.6.1.1000

CID 7467

Gray Level Co-occurrence Matrix Measurements

1.2.840.10008.6.1.1001

CID 7468

Texture Measurements

1.2.840.10008.6.1.1002

CID 6146

Time Point Types

1.2.840.10008.6.1.1003

CID 7469

Generic Intensity and Size Measurements

1.2.840.10008.6.1.1004

CID 6147

Response Criteria

1.2.840.10008.6.1.1005

CID 12020

Fetal Biometry Anatomic Sites

1.2.840.10008.6.1.1006

CID 12021

Fetal Long Bone Anatomic Sites

1.2.840.10008.6.1.1007

CID 12022

Fetal Cranium Anatomic Sites

1.2.840.10008.6.1.1008

CID 12023

Pelvis and Uterus Anatomic Sites

1.2.840.10008.6.1.1009

CID 7222

Parametric Map Derivation Image Purpose of Reference

1.2.840.10008.6.1.1010

CID 9000

Physical Quantity Descriptors

1.2.840.10008.6.1.1011

CID 7600

Lymph Node Anatomic Sites

1.2.840.10008.6.1.1012

CID 7601

Head and Neck Cancer Anatomic Sites

1.2.840.10008.6.1.1013

CID 7701

Fiber Tracts In Brainstem

1.2.840.10008.6.1.1014

CID 7702

Projection and Thalamic Fibers

1.2.840.10008.6.1.1015

CID 7703

Association Fibers

1.2.840.10008.6.1.1016

CID 7704

Limbic System Tracts

1.2.840.10008.6.1.1017

CID 7705

Commissural Fibers

1.2.840.10008.6.1.1018

CID 7706

Cranial Nerves

1.2.840.10008.6.1.1019

CID 7707

Spinal Cord Fibers

1.2.840.10008.6.1.1020

CID 7710

Tractography Anatomic Sites

1.2.840.10008.6.1.1021

CID 4025

Primary Anatomic Structure for Intra-oral Radiography (Supernumerary Dentition - Designation of Teeth)

1.2.840.10008.6.1.1022

CID 4026

Primary Anatomic Structure for Intra-oral and Craniofacial Radiography - Teeth

1.2.840.10008.6.1.1023

CID 9401

IEC61217 Device Position Parameters

1.2.840.10008.6.1.1024

CID 9402

IEC61217 Gantry Position Parameters

1.2.840.10008.6.1.1025

CID 9403

IEC61217 Patient Support Position Parameters

1.2.840.10008.6.1.1026

CID 7035

Actionable Finding Classification

1.2.840.10008.6.1.1027

CID 7036

Image Quality Assessment

1.2.840.10008.6.1.1028

CID 10050

Summary Radiation Exposure Quantities

1.2.840.10008.6.1.1029

CID 4245

Wide Field Ophthalmic Photography Transformation Method

1.2.840.10008.6.1.1030

CID 84

PET Units

1.2.840.10008.6.1.1031

CID 7300

Implant Materials

1.2.840.10008.6.1.1032

CID 7301

Intervention Types

1.2.840.10008.6.1.1033

CID 7302

Implant Templates View Orientations

1.2.840.10008.6.1.1034

CID 7303

Implant Templates Modified View Orientations

1.2.840.10008.6.1.1035

CID 7304

Implant Target Anatomy

1.2.840.10008.6.1.1036

CID 7305

Implant Planning Landmarks

1.2.840.10008.6.1.1037

CID 7306

Human Hip Implant Planning Landmarks

1.2.840.10008.6.1.1038

CID 7307

Implant Component Types

1.2.840.10008.6.1.1039

CID 7308

Human Hip Implant Component Types

1.2.840.10008.6.1.1040

CID 7309

Human Trauma Implant Component Types

1.2.840.10008.6.1.1041

CID 7310

Implant Fixation Method

1.2.840.10008.6.1.1042

CID 7445

Device Participating Roles

1.2.840.10008.6.1.1043

CID 8101

Container Types

1.2.840.10008.6.1.1044

CID 8102

Container Component Types

1.2.840.10008.6.1.1045

CID 8103

Anatomic Pathology Specimen Types

1.2.840.10008.6.1.1046

CID 8104

Breast Tissue Specimen Types

1.2.840.10008.6.1.1047

CID 8109

Specimen Collection Procedure

1.2.840.10008.6.1.1048

CID 8110

Specimen Sampling Procedure

1.2.840.10008.6.1.1049

CID 8111

Specimen Preparation Procedure

1.2.840.10008.6.1.1050

CID 8112

Specimen Stains

1.2.840.10008.6.1.1051

CID 8113

Specimen Preparation Steps

1.2.840.10008.6.1.1052

CID 8114

Specimen Fixatives

1.2.840.10008.6.1.1053

CID 8115

Specimen Embedding Media

1.2.840.10008.6.1.1054

CID 10020

Source of Projection X-Ray Dose Information

1.2.840.10008.6.1.1055

CID 10021

Source of CT Dose Information

1.2.840.10008.6.1.1056

CID 10025

Radiation Dose Reference Points

1.2.840.10008.6.1.1057

CID 501

Volumetric View Description

1.2.840.10008.6.1.1058

CID 502

Volumetric View Modifier

1.2.840.10008.6.1.1059

CID 7260

Diffusion Acquisition Value Types

1.2.840.10008.6.1.1060

CID 7261

Diffusion Model Value Types

1.2.840.10008.6.1.1061

CID 7262

Diffusion Tractography Algorithm Families

1.2.840.10008.6.1.1062

CID 7263

Diffusion Tractography Measurement Types

1.2.840.10008.6.​1.​1063

CID 7490

Research Animal Source Registries

1.2.840.10008.6.​1.​1064

CID 231

Yes-No Only

1.2.840.10008.6.​1.​1065

CID 601

Biosafety Levels

1.2.840.10008.6.​1.​1066

CID 602

Biosafety Control Reasons

1.2.840.10008.6.​1.​1067

CID 7457

Sex - Male Female or Both

1.2.840.10008.6.​1.​1068

CID 603

Animal Room Types

1.2.840.10008.6.​1.​1069

CID 604

Device Reuse

1.2.840.10008.6.​1.​1070

CID 605

Animal Bedding Material

1.2.840.10008.6.​1.​1071

CID 606

Animal Shelter Types

1.2.840.10008.6.​1.​1072

CID 607

Animal Feed Types

1.2.840.10008.6.​1.​1073

CID 608

Animal Feed Sources

1.2.840.10008.6.​1.​1074

CID 609

Animal Feeding Methods

1.2.840.10008.6.​1.​1075

CID 610

Water Types

1.2.840.10008.6.​1.​1076

CID 611

Anesthesia Category Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1077

CID 612

Anesthesia Category Code Type from Anesthesia Quality Initiative (AQI)

1.2.840.10008.6.​1.​1078

CID 613

Anesthesia Induction Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1079

CID 614

Anesthesia Induction Code Type from Anesthesia Quality Initiative (AQI)

1.2.840.10008.6.​1.​1080

CID 615

Anesthesia Maintenance Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1081

CID 616

Anesthesia Maintenance Code Type from Anesthesia Quality Initiative (AQI)

1.2.840.10008.6.​1.​1082

CID 617

Airway Management Method Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1083

CID 618

Airway Management Method Code Type from Anesthesia Quality Initiative (AQI)

1.2.840.10008.6.​1.​1084

CID 619

Airway Management Sub-Method Code Type for Small Animal Anesthesia

1.2.840.10008.6.​1.​1085

CID 620

Airway Management Sub-Method Code Type from Anesthesia Quality Initiative (AQI)

1.2.840.10008.6.​1.​1086

CID 621

Type of Medication for Small Animal Anesthesia

1.2.840.10008.6.​1.​1087

CID 622

Medication Type Code Type from Anesthesia Quality Initiative (AQI)

1.2.840.10008.6.​1.​1088

CID 623

Medication for Small Animal Anesthesia

1.2.840.10008.6.​1.​1089

CID 624

Inhalational Anesthesia Agents for Small Animal Anesthesia

1.2.840.10008.6.​1.​1090

CID 625

Injectable Anesthesia Agents for Small Animal Anesthesia

1.2.840.10008.6.​1.​1091

CID 626

Premedication Agents for Small Animal Anesthesia

1.2.840.10008.6.​1.​1092

CID 627

Neuromuscular Blocking Agents for Small Animal Anesthesia

1.2.840.10008.6.​1.​1093

CID 628

Ancillary Medications for Small Animal Anesthesia

1.2.840.10008.6.​1.​1094

CID 629

Carrier Gases for Small Animal Anesthesia

1.2.840.10008.6.​1.​1095

CID 630

Local Anesthetics for Small Animal Anesthesia

1.2.840.10008.6.​1.​1096

CID 631

Phase of Procedure Requiring Anesthesia

1.2.840.10008.6.​1.​1097

CID 632

Phase of Surgical Procedure Requiring Anesthesia

1.2.840.10008.6.​1.​1098

CID 633

Phase of Imaging Procedure Requiring Anesthesia

1.2.840.10008.6.​1.​1099

CID 634

Phase of Animal Handling

1.2.840.10008.6.​1.​1100

CID 635

Heating Method

1.2.840.10008.6.​1.​1101

CID 636

Temperature Sensor Device Component Type for Small Animal Procedures

1.2.840.10008.6.​1.​1102

CID 637

Exogenous Substance Types

1.2.840.10008.6.​1.​1103

CID 638

Exogenous Substance

1.2.840.10008.6.​1.​1104

CID 639

Tumor Graft Histologic Type

1.2.840.10008.6.​1.​1105

CID 640

Fibrils

1.2.840.10008.6.​1.​1106

CID 641

Viruses

1.2.840.10008.6.​1.​1107

CID 642

Cytokines

1.2.840.10008.6.​1.​1108

CID 643

Toxins

1.2.840.10008.6.​1.​1109

CID 644

Exogenous Substance Administration Sites

1.2.840.10008.6.​1.​1110

CID 645

Exogenous Substance Tissue of Origin

1.2.840.10008.6.​1.​1111

CID 646

Preclinical Small Animal Imaging Procedures

1.2.840.10008.6.​1.​1112

CID 647

Position Reference Indicator for Frame of Reference

1.2.840.10008.6.​1.​1113

CID 241

Present-Absent Only

1.2.840.10008.6.​1.​1114

CID 10024

Water Equivalent Diameter Method

1.2.840.10008.6.​1.​1115

CID 7022

Radiotherapy Purposes of Reference

1.2.840.10008.6.​1.​1116

CID 701

Content Assessment Types

1.2.840.10008.6.​1.​1117

CID 702

RT Content Assessment Types

1.2.840.10008.6.​1.​1118

CID 703

Basis of Assessment

1.2.840.10008.6.​1.​1119

CID 7449

Reader Specialty

1.2.840.10008.6.​1.​1120

CID 9233

Requested Report Types

1.2.840.10008.6.1.1121

CID 1000

CT Transverse Plane Reference Basis

1.2.840.10008.6.1.1122

CID 1001

Anatomical Reference Basis

1.2.840.10008.6.1.1123

CID 1002

Anatomical Reference Basis - Head

1.2.840.10008.6.1.1124

CID 1003

Anatomical Reference Basis - Spine

1.2.840.10008.6.1.1125

CID 1004

Anatomical Reference Basis - Chest

1.2.840.10008.6.1.1126

CID 1005

Anatomical Reference Basis - Abdomen/Pelvis

1.2.840.10008.6.1.1127

CID 1006

Anatomical Reference Basis - Extremities

1.2.840.10008.6.1.1128

CID 1010

Reference Geometry - Planes

1.2.840.10008.6.1.1129

CID 1011

Reference Geometry - Points

1.2.840.10008.6.1.1130

CID 1015

Patient Alignment Methods

1.2.840.10008.6.1.1131

CID 1200

Contraindications For CT Imaging

1.2.840.10008.6.1.1132

CID 7110

Fiducials Categories

1.2.840.10008.6.1.1133

CID 7111

Fiducials

1.2.840.10008.6.1.1134

CID 7013

Non-Image Source Instance Purposes of Reference

1.2.840.10008.6.1.1135

CID 7023

RT Process Output

1.2.840.10008.6.1.1136

CID 7024

RT Process Input

1.2.840.10008.6.1.1137

CID 7025

RT Process Input Used

1.2.840.10008.6.1.1138

CID 6300

Prostate Sector Anatomy

1.2.840.10008.6.1.1139

CID 6301

Prostate Sector Anatomy from PI-RADS v2

1.2.840.10008.6.1.1140

CID 6302

Prostate Sector Anatomy from European Concensus 16 Sector (Minimal) Model

1.2.840.10008.6.1.1141

CID 6303

Prostate Sector Anatomy from European Concensus 27 Sector (Optimal) Model

1.2.840.10008.6.1.1142

CID 12301

Measurement Selection Reasons

1.2.840.10008.6.1.1143

CID 12302

Echo Finding Observation Types

1.2.840.10008.6.1.1144

CID 12303

Echo Measurement Types

1.2.840.10008.6.1.1145

CID 12304

Echo Measured Properties

1.2.840.10008.6.1.1146

CID 12305

Basic Echo Anatomic Sites

1.2.840.10008.6.1.1147

CID 12306

Echo Flow Directions

1.2.840.10008.6.1.1148

CID 12307

Cardiac Phases and Time Points

1.2.840.10008.6.1.1149

CID 12300

Core Echo Measurements

1.2.840.10008.6.1.1150

CID 4270

OCT-A Processing Algorithm Families

1.2.840.10008.6.1.1151

CID 4271

En Face Image Types

1.2.840.10008.6.1.1152

CID 4272

Opt Scan Pattern Types

1.2.840.10008.6.1.1153

CID 4273

Retinal Segmentation Surfaces

1.2.840.10008.6.1.1154

CID 10060

Organs for Radiation Dose Estimates

1.2.840.10008.6.1.1155

CID 10061

Absorbed Radiation Dose Types

1.2.840.10008.6.1.1156

CID 10062

Equivalent Radiation Dose Types

1.2.840.10008.6.1.1157

CID 10063

Radiation Dose Estimate Distribution Representation

1.2.840.10008.6.1.1158

CID 10064

Patient Model Type

1.2.840.10008.6.1.1159

CID 10065

Radiation Transport Model Type

1.2.840.10008.6.1.1160

CID 10066

Attenuator Category

1.2.840.10008.6.1.1161

CID 10067

Radiation Attenuator Materials

1.2.840.10008.6.1.1162

CID 10068

Estimate Method Types

1.2.840.10008.6.1.1163

CID 10069

Radiation Dose Estimation Parameter

1.2.840.10008.6.1.1164

CID 10070

Radiation Dose Types

1.2.840.10008.6.1.1165

CID 7270

MR Diffusion Component Semantics

1.2.840.10008.6.1.1166

CID 7271

MR Diffusion Anisotropy Indices

1.2.840.10008.6.1.1167

CID 7272

MR Diffusion Model Parameters

1.2.840.10008.6.1.1168

CID 7273

MR Diffusion Models

1.2.840.10008.6.1.1169

CID 7274

MR Diffusion Model Fitting Methods

1.2.840.10008.6.1.1170

CID 7275

MR Diffusion Model Specific Methods

1.2.840.10008.6.1.1171

CID 7276

MR Diffusion Model Inputs

1.2.840.10008.6.1.1172

CID 7277

Units of Diffusion Rate Area Over Time

1.2.840.10008.6.1.1173

CID 7039

Pediatric Size Categories

1.2.840.10008.6.1.1174

CID 7041

Calcium Scoring Patient Size Categories

1.2.840.10008.6.1.1175

CID 10034

Reason for Repeating Acquisition

1.2.840.10008.6.1.1176

CID 800

Protocol Assertion Codes

1.2.840.10008.6.1.1177

CID 7026

Radiotherapeutic Dose Measurement Devices

1.2.840.10008.6.1.1178

CID 7014

Export Additional Information Document Titles

1.2.840.10008.6.1.1179

CID 7015

Export Delay Reasons

1.2.840.10008.6.1.1180

CID 7016

Level of Difficulty

1.2.840.10008.6.1.1181

CID 7017

Category of Teaching Material - Imaging

1.2.840.10008.6.1.1182

CID 7018

Miscellaneous Document Titles

1.2.840.10008.6.1.1183

CID 7019

Segmentation Non-Image Source Purposes of Reference

1.2.840.10008.6.1.1184

CID 280

Longitudinal Temporal Event Types

1.2.840.10008.6.1.1185

CID 6401

Non-lesion Object Type - Physical Objects

1.2.840.10008.6.1.1186

CID 6402

Non-lesion Object Type - Substances

1.2.840.10008.6.1.1187

CID 6403

Non-lesion Object Type - Tissues

1.2.840.10008.6.1.1188

CID 6404

Chest Non-lesion Object Type - Physical Objects

1.2.840.10008.6.1.1189

CID 6405

Chest Non-lesion Object Type - Tissues

1.2.840.10008.6.1.1190

CID 7191

Tissue Segmentation Property Types

1.2.840.10008.6.1.1191

CID 7192

Anatomical Structure Segmentation Property Types

1.2.840.10008.6.1.1192

CID 7193

Physical Object Segmentation Property Types

1.2.840.10008.6.1.1193

CID 7194

Morphologically Abnormal Structure Segmentation Property Types

1.2.840.10008.6.1.1194

CID 7195

Function Segmentation Property Types

1.2.840.10008.6.1.1195

CID 7196

Spatial and Relational Concept Segmentation Property Types

1.2.840.10008.6.1.1196

CID 7197

Body Substance Segmentation Property Types

1.2.840.10008.6.1.1197

CID 7198

Substance Segmentation Property Types

1.2.840.10008.6.1.1198

CID 9303

Interpretation Request Discontinuation Reasons

1.2.840.10008.6.1.1199

CID 7475

Gray Level Run Length Based Features

1.2.840.10008.6.1.1200

CID 7476

Gray Level Size Zone Based Features

1.2.840.10008.6.1.1201

CID 7060

Encapsulated Document Source Purposes of Reference

1.2.840.10008.6.1.1202

CID 7061

Model Document Titles

1.2.840.10008.6.1.1203

CID 7062

Purpose of Reference to Predecessor 3D Model

1.2.840.10008.6.1.1204

CID 7063

Model Scale Units

1.2.840.10008.6.1.1205

CID 7064

Model Usage

1.2.840.10008.6.1.1206

CID 10071

Radiation Dose Units

1.2.840.10008.6.1.1207

CID 7112

Radiotherapy Fiducials

1.2.840.10008.6.1.1208

CID 300

Multi-energy Relevant Materials

1.2.840.10008.6.1.1209

CID 301

Multi-energy Material Units

1.2.840.10008.6.1.1210

CID 9500

Dosimetric Objective Types

1.2.840.10008.6.1.1211

CID 9501

Prescription Anatomy Categories

1.2.840.10008.6.1.1212

CID 9502

RT Segment Annotation Categories

1.2.840.10008.6.1.1213

CID 9503

Radiotherapy Therapeutic Role Categories

1.2.840.10008.6.1.1214

CID 9504

RT Geometric Information

1.2.840.10008.6.1.1215

CID 9505

Fixation or Positioning Devices

1.2.840.10008.6.1.1216

CID 9506

Brachytherapy Devices

1.2.840.10008.6.1.1217

CID 9507

External Body Models

1.2.840.10008.6.1.1218

CID 9508

Non-specific Volumes

1.2.840.10008.6.1.1219

CID 9509

Purpose of Reference For RT Physician Intent Input

1.2.840.10008.6.1.1220

CID 9510

Purpose of Reference For RT Treatment Planning Input

1.2.840.10008.6.1.1221

CID 9511

General External Radiotherapy Procedure Techniques

1.2.840.10008.6.1.1222

CID 9512

Tomotherapeutic Radiotherapy Procedure Techniques

1.2.840.10008.6.1.1223

CID 9513

Fixation Devices

1.2.840.10008.6.1.1224

CID 9514

Anatomical Structures For Radiotherapy

1.2.840.10008.6.1.1225

CID 9515

RT Patient Support Devices

1.2.840.10008.6.1.1226

CID 9516

Radiotherapy Bolus Device Types

1.2.840.10008.6.1.1227

CID 9517

Radiotherapy Block Device Types

1.2.840.10008.6.1.1228

CID 9518

Radiotherapy Accessory No-slot Holder Device Types

1.2.840.10008.6.1.1229

CID 9519

Radiotherapy Accessory Slot Holder Device Types

1.2.840.10008.6.1.1230

CID 9520

Segmented RT Accessory Devices

1.2.840.10008.6.1.1231

CID 9521

Radiotherapy Treatment Energy Unit

1.2.840.10008.6.1.1232

CID 9522

Multi-source Radiotherapy Procedure Techniques

1.2.840.10008.6.1.1233

CID 9523

Robotic Radiotherapy Procedure Techniques

1.2.840.10008.6.1.1234

CID 9524

Radiotherapy Procedure Techniques

1.2.840.10008.6.1.1235

CID 9525

Radiation Therapy Particle

1.2.840.10008.6.1.1236

CID 9526

Ion Therapy Particle

1.2.840.10008.6.1.1237

CID 9527

Teletherapy Isotope

1.2.840.10008.6.1.1238

CID 9528

Brachytherapy Isotope

1.2.840.10008.6.1.1239

CID 9529

Single Dose Dosimetric Objectives

1.2.840.10008.6.1.1240

CID 9530

Percentage and Dose Dosimetric Objectives

1.2.840.10008.6.1.1241

CID 9531

Volume and Dose Dosimetric Objectives

1.2.840.10008.6.1.1242

CID 9532

No-Parameter Dosimetric Objectives

1.2.840.10008.6.1.1243

CID 9533

Delivery Time Structure

1.2.840.10008.6.1.1244

CID 9534

Radiotherapy Targets

1.2.840.10008.6.1.1245

CID 9535

Radiotherapy Dose Calculation Roles

1.2.840.10008.6.1.1246

CID 9536

Radiotherapy Prescribing and Segmenting Person Roles

1.2.840.10008.6.1.1247

CID 9537

Effective Dose Calculation Method Categories

1.2.840.10008.6.1.1248

CID 9538

Radiation Transport-based Effective Dose Method Modifiers

1.2.840.10008.6.1.1249

CID 9539

Fractionation-based Effective Dose Method Modifiers

1.2.840.10008.6.1.1250

CID 60

Imaging Agent Administration Adverse Events

1.2.840.10008.6.1.1251

CID 61

Time Relative to Procedure

1.2.840.10008.6.1.1252

CID 62

Imaging Agent Administration Phase Type

1.2.840.10008.6.1.1253

CID 63

Imaging Agent Administration Mode

1.2.840.10008.6.1.1254

CID 64

Imaging Agent Administration Patient State

1.2.840.10008.6.1.1255

CID 65

Pre-medication For Imaging Agent Administration

1.2.840.10008.6.1.1256

CID 66

Medication For Imaging Agent Administration

1.2.840.10008.6.1.1257

CID 67

Imaging Agent Administration Completion Status

1.2.840.10008.6.1.1258

CID 68

Imaging Agent Administration Pharmaceutical Unit of Presentation

1.2.840.10008.6.1.1259

CID 69

Imaging Agent Administration Consumables

1.2.840.10008.6.1.1260

CID 70

Flush

1.2.840.10008.6.1.1261

CID 71

Imaging Agent Administration Injector Event Type

1.2.840.10008.6.1.1262

CID 72

Imaging Agent Administration Step Type

1.2.840.10008.6.1.1263

CID 73

Bolus Shaping Curves

1.2.840.10008.6.1.1264

CID 74

Imaging Agent Administration Consumable Catheter Type

1.2.840.10008.6.1.1265

CID 75

Low-high-equal

1.2.840.10008.6.1.1266

CID 76

Type of Pre-medication


Note

For some Context Group UIDs, no Context Group Name or Identifier is specified; these are "placeholders" that are not assigned but will not be reused.

Table A-4. Template UID Values

UID Value

UID Name

UID Type

Part

1.2.840.10008.9.1

Imaging Report

Document TemplateID

PS3.20

1.2.840.10008.9.2

Clinical Information

Section TemplateID

PS3.20

1.2.840.10008.9.3

Imaging Procedure Description

Section TemplateID

PS3.20

1.2.840.10008.9.4

Comparison Study

Section TemplateID

PS3.20

1.2.840.10008.9.5

Impression

Section TemplateID

PS3.20

1.2.840.10008.9.6

Addendum

Section TemplateID

PS3.20

1.2.840.10008.9.7

Request

Section TemplateID

PS3.20

1.2.840.10008.9.8

Radiation Exposure and Protection Information

Section TemplateID

PS3.20

1.2.840.10008.9.9

Fetus Findings

Section TemplateID

PS3.20

1.2.840.10008.9.10

Labeled Subsection

Section TemplateID

PS3.20

1.2.840.10008.9.11

Communication of Actionable Findings

Section TemplateID

PS3.20

1.2.840.10008.9.12

Recommendation

Section TemplateID

PS3.20

1.2.840.10008.9.13

Procedural Medication

Entry TemplateID

PS3.20

1.2.840.10008.9.14

Procedure Technique

Entry TemplateID

PS3.20

1.2.840.10008.9.15

Image Quality

Entry TemplateID

PS3.20

1.2.840.10008.9.16

Study Act

Entry TemplateID

PS3.20

1.2.840.10008.9.17

Series Act

Entry TemplateID

PS3.20

1.2.840.10008.9.18

SOP Instance Observation

Entry TemplateID

PS3.20

1.2.840.10008.9.19

Section Text

Element Set TemplateID

PS3.20

1.2.840.10008.9.20

General Header

Element Set TemplateID

PS3.20

1.2.840.10008.9.21

Imaging Header

Element Set TemplateID

PS3.20

1.2.840.10008.9.22

Parent Document

Element Set TemplateID

PS3.20

1.2.840.10008.9.23

General Section Entries

Element Set TemplateID

PS3.20

1.2.840.10008.9.24

Imaging Addendum Report

Document TemplateID

PS3.20


DICOM PS3.6 2018e - Data Dictionary