1.2.840.10008.1.1
|
Verification SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.2
|
Implicit VR Little Endian: Default Transfer Syntax for DICOM
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.1
|
Explicit VR Little Endian
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.1.99
|
Deflated Explicit VR Little Endian
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.2
|
Explicit VR Big Endian (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.50
|
JPEG Baseline (Process 1): Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.51
|
JPEG Extended (Process 2 & 4): Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.52
|
JPEG Extended (Process 3 & 5) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.53
|
JPEG Spectral Selection, Non-Hierarchical (Process 6 & 8) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.54
|
JPEG Spectral Selection, Non-Hierarchical (Process 7 & 9) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.55
|
JPEG Full Progression, Non-Hierarchical (Process 10 & 12) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.56
|
JPEG Full Progression, Non-Hierarchical (Process 11 & 13) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.57
|
JPEG Lossless, Non-Hierarchical (Process 14)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.58
|
JPEG Lossless, Non-Hierarchical (Process 15) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.59
|
JPEG Extended, Hierarchical (Process 16 & 18) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.60
|
JPEG Extended, Hierarchical (Process 17 & 19) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.61
|
JPEG Spectral Selection, Hierarchical (Process 20 & 22) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.62
|
JPEG Spectral Selection, Hierarchical (Process 21 & 23) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.63
|
JPEG Full Progression, Hierarchical (Process 24 & 26) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.64
|
JPEG Full Progression, Hierarchical (Process 25 & 27) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.65
|
JPEG Lossless, Hierarchical (Process 28) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.66
|
JPEG Lossless, Hierarchical (Process 29) (Retired)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.70
|
JPEG Lossless, Non-Hierarchical, First-Order Prediction (Process 14 [Selection Value 1]): Default Transfer Syntax for Lossless JPEG Image Compression
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.80
|
JPEG-LS Lossless Image Compression
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.81
|
JPEG-LS Lossy (Near-Lossless) Image Compression
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.90
|
JPEG 2000 Image Compression (Lossless Only)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.91
|
JPEG 2000 Image Compression
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.92
|
JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.93
|
JPEG 2000 Part 2 Multi-component Image Compression
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.94
|
JPIP Referenced
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.95
|
JPIP Referenced Deflate
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.100
|
MPEG2 Main Profile @ Main Level
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.101
|
MPEG2 Main Profile @ High Level
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.102
|
MPEG-4 AVC/H.264 High Profile / Level 4.1
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.103
|
MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.104
|
MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.105
|
MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.4.106
|
MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.5
|
RLE Lossless
|
Transfer Syntax
|
PS3.5
|
1.2.840.10008.1.2.6.1
|
RFC 2557 MIME encapsulation
|
Transfer Syntax
|
PS3.10
|
1.2.840.10008.1.2.6.2
|
XML Encoding
|
Transfer Syntax
|
PS3.10
|
1.2.840.10008.1.3.10
|
Media Storage Directory Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.4.1.1
|
Talairach Brain Atlas Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.2
|
SPM2 T1 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.3
|
SPM2 T2 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.4
|
SPM2 PD Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.5
|
SPM2 EPI Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.6
|
SPM2 FIL T1 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.7
|
SPM2 PET Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.8
|
SPM2 TRANSM Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.9
|
SPM2 SPECT Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.10
|
SPM2 GRAY Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.11
|
SPM2 WHITE Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.12
|
SPM2 CSF Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.13
|
SPM2 BRAINMASK Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.14
|
SPM2 AVG305T1 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.15
|
SPM2 AVG152T1 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.16
|
SPM2 AVG152T2 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.17
|
SPM2 AVG152PD Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.1.18
|
SPM2 SINGLESUBJT1 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.2.1
|
ICBM 452 T1 Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.4.2.2
|
ICBM Single Subject MRI Frame of Reference
|
Well-known frame of reference
|
|
1.2.840.10008.1.5.1
|
Hot Iron Color Palette SOP Instance
|
Well-known SOP Instance
|
PS 3.6
|
1.2.840.10008.1.5.2
|
PET Color Palette SOP Instance
|
Well-known SOP Instance
|
PS 3.6
|
1.2.840.10008.1.5.3
|
Hot Metal Blue Color Palette SOP Instance
|
Well-known SOP Instance
|
PS 3.6
|
1.2.840.10008.1.5.4
|
PET 20 Step Color Palette SOP Instance
|
Well-known SOP Instance
|
PS 3.6
|
1.2.840.10008.1.9
|
Basic Study Content Notification SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.20
|
Papyrus 3 Implicit VR Little Endian (Retired)
|
Transfer Syntax
|
|
1.2.840.10008.1.20.1
|
Storage Commitment Push Model SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.20.1.1
|
Storage Commitment Push Model SOP Instance
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.1.20.2
|
Storage Commitment Pull Model SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.20.2.1
|
Storage Commitment Pull Model SOP Instance (Retired)
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.1.40
|
Procedural Event Logging SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.40.1
|
Procedural Event Logging SOP Instance
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.1.42
|
Substance Administration Logging SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.1.42.1
|
Substance Administration Logging SOP Instance
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.2.6.1
|
DICOM UID Registry
|
DICOM UIDs as a Coding Scheme
|
PS 3.6
|
1.2.840.10008.2.16.4
|
DICOM Controlled Terminology
|
Coding Scheme
|
PS3.16
|
1.2.840.10008.2.16.5
|
Adult Mouse Anatomy Ontology
|
Coding Scheme
|
PS3.16
|
1.2.840.10008.2.16.6
|
Uberon Ontology
|
Coding Scheme
|
PS3.16
|
1.2.840.10008.2.16.7
|
Integrated Taxonomic Information System (ITIS) Taxonomic Serial Number (TSN)
|
Coding Scheme
|
PS3.16
|
1.2.840.10008.2.16.8
|
Mouse Genome Initiative (MGI)
|
Coding Scheme
|
PS3.16
|
1.2.840.10008.2.16.9
|
PubChem Compound CID
|
Coding Scheme
|
PS3.16
|
1.2.840.10008.3.1.1.1
|
DICOM Application Context Name
|
Application Context Name
|
PS3.7
|
1.2.840.10008.3.1.2.1.1
|
Detached Patient Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.1.4
|
Detached Patient Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.2.1
|
Detached Visit Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.3.1
|
Detached Study Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.3.2
|
Study Component Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.3.3
|
Modality Performed Procedure Step SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.3.4
|
Modality Performed Procedure Step Retrieve SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.3.5
|
Modality Performed Procedure Step Notification SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.5.1
|
Detached Results Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.5.4
|
Detached Results Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.5.5
|
Detached Study Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.3.1.2.6.1
|
Detached Interpretation Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.4.2
|
Storage Service Class
|
Service Class
|
PS3.4
|
1.2.840.10008.5.1.1.1
|
Basic Film Session SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.2
|
Basic Film Box SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.4
|
Basic Grayscale Image Box SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.4.1
|
Basic Color Image Box SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.4.2
|
Referenced Image Box SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.9
|
Basic Grayscale Print Management Meta SOP Class
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.9.1
|
Referenced Grayscale Print Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.14
|
Print Job SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.15
|
Basic Annotation Box SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.16
|
Printer SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.16.376
|
Printer Configuration Retrieval SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.17
|
Printer SOP Instance
|
Well-known Printer SOP Instance
|
PS3.4
|
1.2.840.10008.5.1.1.17.376
|
Printer Configuration Retrieval SOP Instance
|
Well-known Printer SOP Instance
|
PS3.4
|
1.2.840.10008.5.1.1.18
|
Basic Color Print Management Meta SOP Class
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.18.1
|
Referenced Color Print Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.22
|
VOI LUT Box SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.23
|
Presentation LUT SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.24
|
Image Overlay Box SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.24.1
|
Basic Print Image Overlay Box SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.25
|
Print Queue SOP Instance (Retired)
|
Well-known Print Queue SOP Instance
|
PS3.4
|
1.2.840.10008.5.1.1.26
|
Print Queue Management SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.27
|
Stored Print Storage SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.29
|
Hardcopy Grayscale Image Storage SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.30
|
Hardcopy Color Image Storage SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.31
|
Pull Print Request SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.32
|
Pull Stored Print Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.33
|
Media Creation Management SOP Class UID
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.40
|
Display System SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.1.40.1
|
Display System SOP Instance
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1
|
Computed Radiography Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1.1
|
Digital X-Ray Image Storage - For Presentation
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1.1.1
|
Digital X-Ray Image Storage - For Processing
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1.2
|
Digital Mammography X-Ray Image Storage - For Presentation
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1.2.1
|
Digital Mammography X-Ray Image Storage - For Processing
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1.3
|
Digital Intra-Oral X-Ray Image Storage - For Presentation
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.1.3.1
|
Digital Intra-Oral X-Ray Image Storage - For Processing
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.2
|
CT Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.2.1
|
Enhanced CT Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.2.2
|
Legacy Converted Enhanced CT Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.3
|
Ultrasound Multi-frame Image Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.3.1
|
Ultrasound Multi-frame Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.4
|
MR Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.4.1
|
Enhanced MR Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.4.2
|
MR Spectroscopy Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.4.3
|
Enhanced MR Color Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.4.4
|
Legacy Converted Enhanced MR Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.5
|
Nuclear Medicine Image Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.6
|
Ultrasound Image Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.6.1
|
Ultrasound Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.6.2
|
Enhanced US Volume Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.7
|
Secondary Capture Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.7.1
|
Multi-frame Single Bit Secondary Capture Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.7.2
|
Multi-frame Grayscale Byte Secondary Capture Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.7.3
|
Multi-frame Grayscale Word Secondary Capture Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.7.4
|
Multi-frame True Color Secondary Capture Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.8
|
Standalone Overlay Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9
|
Standalone Curve Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.1
|
Waveform Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.1.1
|
12-lead ECG Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.1.2
|
General ECG Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.1.3
|
Ambulatory ECG Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.2.1
|
Hemodynamic Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.3.1
|
Cardiac Electrophysiology Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.4.1
|
Basic Voice Audio Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.4.2
|
General Audio Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.5.1
|
Arterial Pulse Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.9.6.1
|
Respiratory Waveform Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.10
|
Standalone Modality LUT Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11
|
Standalone VOI LUT Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.1
|
Grayscale Softcopy Presentation State Storage SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.2
|
Color Softcopy Presentation State Storage SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.3
|
Pseudo-Color Softcopy Presentation State Storage SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.4
|
Blending Softcopy Presentation State Storage SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.5
|
XA/XRF Grayscale Softcopy Presentation State Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.6
|
Grayscale Planar MPR Volumetric Presentation State Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.11.7
|
Compositing Planar MPR Volumetric Presentation State Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.12.1
|
X-Ray Angiographic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.12.1.1
|
Enhanced XA Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.12.2
|
X-Ray Radiofluoroscopic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.12.2.1
|
Enhanced XRF Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.12.3
|
X-Ray Angiographic Bi-Plane Image Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.12.77
|
(Retired)
|
SOP Class
|
|
1.2.840.10008.5.1.4.1.1.13.1.1
|
X-Ray 3D Angiographic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.13.1.2
|
X-Ray 3D Craniofacial Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.13.1.3
|
Breast Tomosynthesis Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.13.1.4
|
Breast Projection X-Ray Image Storage - For Presentation
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.13.1.5
|
Breast Projection X-Ray Image Storage - For Processing
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.14.1
|
Intravascular Optical Coherence Tomography Image Storage - For Presentation
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.14.2
|
Intravascular Optical Coherence Tomography Image Storage - For Processing
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.20
|
Nuclear Medicine Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.30
|
Parametric Map Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.40
|
(Retired)
|
SOP Class
|
|
1.2.840.10008.5.1.4.1.1.66
|
Raw Data Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.66.1
|
Spatial Registration Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.66.2
|
Spatial Fiducials Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.66.3
|
Deformable Spatial Registration Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.66.4
|
Segmentation Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.66.5
|
Surface Segmentation Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.66.6
|
Tractography Results Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.67
|
Real World Value Mapping Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.68.1
|
Surface Scan Mesh Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.68.2
|
Surface Scan Point Cloud Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1
|
VL Image Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.2
|
VL Multi-frame Image Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.1
|
VL Endoscopic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.1.1
|
Video Endoscopic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.2
|
VL Microscopic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.2.1
|
Video Microscopic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.3
|
VL Slide-Coordinates Microscopic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.4
|
VL Photographic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.4.1
|
Video Photographic Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.5.1
|
Ophthalmic Photography 8 Bit Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.5.2
|
Ophthalmic Photography 16 Bit Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.5.3
|
Stereometric Relationship Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.5.4
|
Ophthalmic Tomography Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.5.5
|
Wide Field Ophthalmic Photography Stereographic Projection Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.5.6
|
Wide Field Ophthalmic Photography 3D Coordinates Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.77.1.6
|
VL Whole Slide Microscopy Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.1
|
Lensometry Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.2
|
Autorefraction Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.3
|
Keratometry Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.4
|
Subjective Refraction Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.5
|
Visual Acuity Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.6
|
Spectacle Prescription Report Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.7
|
Ophthalmic Axial Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.78.8
|
Intraocular Lens Calculations Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.79.1
|
Macular Grid Thickness and Volume Report Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.80.1
|
Ophthalmic Visual Field Static Perimetry Measurements Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.81.1
|
Ophthalmic Thickness Map Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.82.1
|
Corneal Topography Map Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.1
|
Text SR Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.2
|
Audio SR Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.3
|
Detail SR Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.4
|
Comprehensive SR Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.11
|
Basic Text SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.22
|
Enhanced SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.33
|
Comprehensive SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.34
|
Comprehensive 3D SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.35
|
Extensible SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.40
|
Procedure Log Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.50
|
Mammography CAD SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.59
|
Key Object Selection Document Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.65
|
Chest CAD SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.67
|
X-Ray Radiation Dose SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.68
|
Radiopharmaceutical Radiation Dose SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.69
|
Colon CAD SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.70
|
Implantation Plan SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.88.71
|
Acquisition Context SR Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.90.1
|
Content Assessment Results Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.104.1
|
Encapsulated PDF Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.104.2
|
Encapsulated CDA Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.128
|
Positron Emission Tomography Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.128.1
|
Legacy Converted Enhanced PET Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.129
|
Standalone PET Curve Storage (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.130
|
Enhanced PET Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.131
|
Basic Structured Display Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.1
|
RT Image Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.2
|
RT Dose Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.3
|
RT Structure Set Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.4
|
RT Beams Treatment Record Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.5
|
RT Plan Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.6
|
RT Brachy Treatment Record Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.7
|
RT Treatment Summary Record Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.8
|
RT Ion Plan Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.481.9
|
RT Ion Beams Treatment Record Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.1.501.1
|
DICOS CT Image Storage
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.501.2.1
|
DICOS Digital X-Ray Image Storage - For Presentation
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.501.2.2
|
DICOS Digital X-Ray Image Storage - For Processing
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.501.3
|
DICOS Threat Detection Report Storage
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.501.4
|
DICOS 2D AIT Storage
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.501.5
|
DICOS 3D AIT Storage
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.501.6
|
DICOS Quadrupole Resonance (QR) Storage
|
SOP Class
|
DICOS
|
1.2.840.10008.5.1.4.1.1.601.1
|
Eddy Current Image Storage
|
SOP Class
|
DICONDE ASTM E2934
|
1.2.840.10008.5.1.4.1.1.601.2
|
Eddy Current Multi-frame Image Storage
|
SOP Class
|
DICONDE ASTM E2934
|
1.2.840.10008.5.1.4.1.2.1.1
|
Patient Root Query/Retrieve Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.1.2
|
Patient Root Query/Retrieve Information Model - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.1.3
|
Patient Root Query/Retrieve Information Model - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.2.1
|
Study Root Query/Retrieve Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.2.2
|
Study Root Query/Retrieve Information Model - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.2.3
|
Study Root Query/Retrieve Information Model - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.3.1
|
Patient/Study Only Query/Retrieve Information Model - FIND (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.3.2
|
Patient/Study Only Query/Retrieve Information Model - MOVE (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.3.3
|
Patient/Study Only Query/Retrieve Information Model - GET (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.4.2
|
Composite Instance Root Retrieve - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.4.3
|
Composite Instance Root Retrieve - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.1.2.5.3
|
Composite Instance Retrieve Without Bulk Data - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.31
|
Modality Worklist Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.32
|
General Purpose Worklist Management Meta SOP Class (Retired)
|
Meta SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.32.1
|
General Purpose Worklist Information Model - FIND (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.32.2
|
General Purpose Scheduled Procedure Step SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.32.3
|
General Purpose Performed Procedure Step SOP Class (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.33
|
Instance Availability Notification SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.1
|
RT Beams Delivery Instruction Storage - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.2
|
RT Conventional Machine Verification - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.3
|
RT Ion Machine Verification - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.4
|
Unified Worklist and Procedure Step Service Class - Trial (Retired)
|
Service Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.4.1
|
Unified Procedure Step - Push SOP Class - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.4.2
|
Unified Procedure Step - Watch SOP Class - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.4.3
|
Unified Procedure Step - Pull SOP Class - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.4.4
|
Unified Procedure Step - Event SOP Class - Trial (Retired)
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.5
|
UPS Global Subscription SOP Instance
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.5.1.4.34.5.1
|
UPS Filtered Global Subscription SOP Instance
|
Well-known SOP Instance
|
PS3.4
|
1.2.840.10008.5.1.4.34.6
|
Unified Worklist and Procedure Step Service Class
|
Service Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.6.1
|
Unified Procedure Step - Push SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.6.2
|
Unified Procedure Step - Watch SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.6.3
|
Unified Procedure Step - Pull SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.6.4
|
Unified Procedure Step - Event SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.7
|
RT Beams Delivery Instruction Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.8
|
RT Conventional Machine Verification
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.9
|
RT Ion Machine Verification
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.34.10
|
RT Brachy Application Setup Delivery Instruction Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.37.1
|
General Relevant Patient Information Query
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.37.2
|
Breast Imaging Relevant Patient Information Query
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.37.3
|
Cardiac Relevant Patient Information Query
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.38.1
|
Hanging Protocol Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.38.2
|
Hanging Protocol Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.38.3
|
Hanging Protocol Information Model - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.38.4
|
Hanging Protocol Information Model - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.39.1
|
Color Palette Storage
|
Transfer
|
PS3.4
|
1.2.840.10008.5.1.4.39.2
|
Color Palette Information Model - FIND
|
Query/Retrieve
|
PS3.4
|
1.2.840.10008.5.1.4.39.3
|
Color Palette Information Model - MOVE
|
Query/Retrieve
|
PS3.4
|
1.2.840.10008.5.1.4.39.4
|
Color Palette Information Model - GET
|
Query/Retrieve
|
PS3.4
|
1.2.840.10008.5.1.4.41
|
Product Characteristics Query SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.42
|
Substance Approval Query SOP Class
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.43.1
|
Generic Implant Template Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.43.2
|
Generic Implant Template Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.43.3
|
Generic Implant Template Information Model - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.43.4
|
Generic Implant Template Information Model - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.44.1
|
Implant Assembly Template Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.44.2
|
Implant Assembly Template Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.44.3
|
Implant Assembly Template Information Model - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.44.4
|
Implant Assembly Template Information Model - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.45.1
|
Implant Template Group Storage
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.45.2
|
Implant Template Group Information Model - FIND
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.45.3
|
Implant Template Group Information Model - MOVE
|
SOP Class
|
PS3.4
|
1.2.840.10008.5.1.4.45.4
|
Implant Template Group Information Model - GET
|
SOP Class
|
PS3.4
|
1.2.840.10008.7.1.1
|
Native DICOM Model
|
Application Hosting Model
|
PS3.19
|
1.2.840.10008.7.1.2
|
Abstract Multi-Dimensional Image Model
|
Application Hosting Model
|
PS3.19
|
1.2.840.10008.8.1.1
|
DICOM Content Mapping Resource
|
Mapping Resource
|
PS3.16
|
1.2.840.10008.15.0.3.1
|
dicomDeviceName
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.2
|
dicomDescription
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.3
|
dicomManufacturer
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.4
|
dicomManufacturerModelName
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.5
|
dicomSoftwareVersion
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.6
|
dicomVendorData
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.7
|
dicomAETitle
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.8
|
dicomNetworkConnectionReference
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.9
|
dicomApplicationCluster
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.10
|
dicomAssociationInitiator
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.11
|
dicomAssociationAcceptor
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.12
|
dicomHostname
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.13
|
dicomPort
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.14
|
dicomSOPClass
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.15
|
dicomTransferRole
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.16
|
dicomTransferSyntax
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.17
|
dicomPrimaryDeviceType
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.18
|
dicomRelatedDeviceReference
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.19
|
dicomPreferredCalledAETitle
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.20
|
dicomTLSCyphersuite
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.21
|
dicomAuthorizedNodeCertificateReference
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.22
|
dicomThisNodeCertificateReference
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.23
|
dicomInstalled
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.24
|
dicomStationName
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.25
|
dicomDeviceSerialNumber
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.26
|
dicomInstitutionName
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.27
|
dicomInstitutionAddress
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.28
|
dicomInstitutionDepartmentName
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.29
|
dicomIssuerOfPatientID
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.30
|
dicomPreferredCallingAETitle
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.3.31
|
dicomSupportedCharacterSet
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.1
|
dicomConfigurationRoot
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.2
|
dicomDevicesRoot
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.3
|
dicomUniqueAETitlesRegistryRoot
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.4
|
dicomDevice
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.5
|
dicomNetworkAE
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.6
|
dicomNetworkConnection
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.7
|
dicomUniqueAETitle
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.0.4.8
|
dicomTransferCapability
|
LDAP OID
|
PS3.15
|
1.2.840.10008.15.1.1
|
Universal Coordinated Time
|
Synchronization Frame of Reference
|
PS3.3
|