DICOM PS3.6 2016c - Data Dictionary

7 Registry of DICOM File Meta Elements

This section specifies the File Meta Elements needed to support the formatting of the File Meta Information of the DICOM File Format (see PS3.10).

Table 7-1. Registry of DICOM File Meta Elements

Tag

Name

Keyword

VR

VM

(0002,0000)

File Meta Information Group Length

File​Meta​Information​Group​Length

UL

1

(0002,0001)

File Meta Information Version

File​Meta​Information​Version

OB

1

(0002,0002)

Media Storage SOP Class UID

Media​StorageSOP​ClassUID

UI

1

(0002,0003)

Media Storage SOP Instance UID

Media​StorageSOP​InstanceUID

UI

1

(0002,0010)

Transfer Syntax UID

Transfer​SyntaxUID

UI

1

(0002,0012)

Implementation Class UID

Implementation​ClassUID

UI

1

(0002,0013)

Implementation Version Name

Implementation​Version​Name

SH

1

(0002,0016)

Source Application Entity Title

Source​Application​Entity​Title

AE

1

(0002,0017)

Sending Application Entity Title

Sending​Application​Entity​Title

AE

1

(0002,0018)

Receiving Application Entity Title

Receiving​Application​Entity​Title

AE

1

(0002,0100)

Private Information Creator UID

Private​Information​CreatorUID

UI

1

(0002,0102)

Private Information

Private​Information

OB

1