(0008,0001)
|
Length to End
|
LengthToEnd
|
UL
|
1
|
RET
|
(0008,0005)
|
Specific Character Set
|
SpecificCharacterSet
|
CS
|
1-n
|
|
(0008,0006)
|
Language Code Sequence
|
LanguageCodeSequence
|
SQ
|
1
|
|
(0008,0008)
|
Image Type
|
ImageType
|
CS
|
2-n
|
|
(0008,0010)
|
Recognition Code
|
RecognitionCode
|
SH
|
1
|
RET
|
(0008,0012)
|
Instance Creation Date
|
InstanceCreationDate
|
DA
|
1
|
|
(0008,0013)
|
Instance Creation Time
|
InstanceCreationTime
|
TM
|
1
|
|
(0008,0014)
|
Instance Creator UID
|
InstanceCreatorUID
|
UI
|
1
|
|
(0008,0015)
|
Instance Coercion DateTime
|
InstanceCoercionDateTime
|
DT
|
1
|
|
(0008,0016)
|
SOP Class UID
|
SOPClassUID
|
UI
|
1
|
|
(0008,0018)
|
SOP Instance UID
|
SOPInstanceUID
|
UI
|
1
|
|
(0008,001A)
|
Related General SOP Class UID
|
RelatedGeneralSOPClassUID
|
UI
|
1-n
|
|
(0008,001B)
|
Original Specialized SOP Class UID
|
OriginalSpecializedSOPClassUID
|
UI
|
1
|
|
(0008,0020)
|
Study Date
|
StudyDate
|
DA
|
1
|
|
(0008,0021)
|
Series Date
|
SeriesDate
|
DA
|
1
|
|
(0008,0022)
|
Acquisition Date
|
AcquisitionDate
|
DA
|
1
|
|
(0008,0023)
|
Content Date
|
ContentDate
|
DA
|
1
|
|
(0008,0024)
|
Overlay Date
|
OverlayDate
|
DA
|
1
|
RET
|
(0008,0025)
|
Curve Date
|
CurveDate
|
DA
|
1
|
RET
|
(0008,002A)
|
Acquisition DateTime
|
AcquisitionDateTime
|
DT
|
1
|
|
(0008,0030)
|
Study Time
|
StudyTime
|
TM
|
1
|
|
(0008,0031)
|
Series Time
|
SeriesTime
|
TM
|
1
|
|
(0008,0032)
|
Acquisition Time
|
AcquisitionTime
|
TM
|
1
|
|
(0008,0033)
|
Content Time
|
ContentTime
|
TM
|
1
|
|
(0008,0034)
|
Overlay Time
|
OverlayTime
|
TM
|
1
|
RET
|
(0008,0035)
|
Curve Time
|
CurveTime
|
TM
|
1
|
RET
|
(0008,0040)
|
Data Set Type
|
DataSetType
|
US
|
1
|
RET
|
(0008,0041)
|
Data Set Subtype
|
DataSetSubtype
|
LO
|
1
|
RET
|
(0008,0042)
|
Nuclear Medicine Series Type
|
NuclearMedicineSeriesType
|
CS
|
1
|
RET
|
(0008,0050)
|
Accession Number
|
AccessionNumber
|
SH
|
1
|
|
(0008,0051)
|
Issuer of Accession Number Sequence
|
IssuerOfAccessionNumberSequence
|
SQ
|
1
|
|
(0008,0052)
|
Query/Retrieve Level
|
QueryRetrieveLevel
|
CS
|
1
|
|
(0008,0053)
|
Query/Retrieve View
|
QueryRetrieveView
|
CS
|
1
|
|
(0008,0054)
|
Retrieve AE Title
|
RetrieveAETitle
|
AE
|
1-n
|
|
(0008,0055)
|
Station AE Title
|
StationAETitle
|
AE
|
1
|
|
(0008,0056)
|
Instance Availability
|
InstanceAvailability
|
CS
|
1
|
|
(0008,0058)
|
Failed SOP Instance UID List
|
FailedSOPInstanceUIDList
|
UI
|
1-n
|
|
(0008,0060)
|
Modality
|
Modality
|
CS
|
1
|
|
(0008,0061)
|
Modalities in Study
|
ModalitiesInStudy
|
CS
|
1-n
|
|
(0008,0062)
|
SOP Classes in Study
|
SOPClassesInStudy
|
UI
|
1-n
|
|
(0008,0064)
|
Conversion Type
|
ConversionType
|
CS
|
1
|
|
(0008,0068)
|
Presentation Intent Type
|
PresentationIntentType
|
CS
|
1
|
|
(0008,0070)
|
Manufacturer
|
Manufacturer
|
LO
|
1
|
|
(0008,0080)
|
Institution Name
|
InstitutionName
|
LO
|
1
|
|
(0008,0081)
|
Institution Address
|
InstitutionAddress
|
ST
|
1
|
|
(0008,0082)
|
Institution Code Sequence
|
InstitutionCodeSequence
|
SQ
|
1
|
|
(0008,0090)
|
Referring Physician's Name
|
ReferringPhysicianName
|
PN
|
1
|
|
(0008,0092)
|
Referring Physician's Address
|
ReferringPhysicianAddress
|
ST
|
1
|
|
(0008,0094)
|
Referring Physician's Telephone Numbers
|
ReferringPhysicianTelephoneNumbers
|
SH
|
1-n
|
|
(0008,0096)
|
Referring Physician Identification Sequence
|
ReferringPhysicianIdentificationSequence
|
SQ
|
1
|
|
(0008,009C)
|
Consulting Physician's Name
|
ConsultingPhysicianName
|
PN
|
1-n
|
|
(0008,009D)
|
Consulting Physician Identification Sequence
|
ConsultingPhysicianIdentificationSequence
|
SQ
|
1
|
|
(0008,0100)
|
Code Value
|
CodeValue
|
SH
|
1
|
|
(0008,0101)
|
Extended Code Value
|
ExtendedCodeValue
|
LO
|
1
|
DICOS
|
(0008,0102)
|
Coding Scheme Designator
|
CodingSchemeDesignator
|
SH
|
1
|
|
(0008,0103)
|
Coding Scheme Version
|
CodingSchemeVersion
|
SH
|
1
|
|
(0008,0104)
|
Code Meaning
|
CodeMeaning
|
LO
|
1
|
|
(0008,0105)
|
Mapping Resource
|
MappingResource
|
CS
|
1
|
|
(0008,0106)
|
Context Group Version
|
ContextGroupVersion
|
DT
|
1
|
|
(0008,0107)
|
Context Group Local Version
|
ContextGroupLocalVersion
|
DT
|
1
|
|
(0008,0108)
|
Extended Code Meaning
|
ExtendedCodeMeaning
|
LT
|
1
|
DICOS
|
(0008,010B)
|
Context Group Extension Flag
|
ContextGroupExtensionFlag
|
CS
|
1
|
|
(0008,010C)
|
Coding Scheme UID
|
CodingSchemeUID
|
UI
|
1
|
|
(0008,010D)
|
Context Group Extension Creator UID
|
ContextGroupExtensionCreatorUID
|
UI
|
1
|
|
(0008,010F)
|
Context Identifier
|
ContextIdentifier
|
CS
|
1
|
|
(0008,0110)
|
Coding Scheme Identification Sequence
|
CodingSchemeIdentificationSequence
|
SQ
|
1
|
|
(0008,0112)
|
Coding Scheme Registry
|
CodingSchemeRegistry
|
LO
|
1
|
|
(0008,0114)
|
Coding Scheme External ID
|
CodingSchemeExternalID
|
ST
|
1
|
|
(0008,0115)
|
Coding Scheme Name
|
CodingSchemeName
|
ST
|
1
|
|
(0008,0116)
|
Coding Scheme Responsible Organization
|
CodingSchemeResponsibleOrganization
|
ST
|
1
|
|
(0008,0117)
|
Context UID
|
ContextUID
|
UI
|
1
|
|
(0008,0118)
|
Mapping Resource UID
|
MappingResourceUID
|
UI
|
1
|
|
(0008,0119)
|
Long Code Value
|
LongCodeValue
|
UC
|
1
|
|
(0008,0120)
|
URN Code Value
|
URNCodeValue
|
UR
|
1
|
|
(0008,0121)
|
Equivalent Code Sequence
|
EquivalentCodeSequence
|
SQ
|
1
|
|
(0008,0122)
|
Mapping Resource Name
|
MappingResourceName
|
LO
|
1
|
|
(0008,0123)
|
Context Group Identification Sequence
|
ContextGroupIdentificationSequence
|
SQ
|
1
|
|
(0008,0124)
|
Mapping Resource Identification Sequence
|
MappingResourceIdentificationSequence
|
SQ
|
1
|
|
(0008,0201)
|
Timezone Offset From UTC
|
TimezoneOffsetFromUTC
|
SH
|
1
|
|
(0008,0300)
|
Private Data Element Characteristics Sequence
|
PrivateDataElementCharacteristicsSequence
|
SQ
|
1
|
|
(0008,0301)
|
Private Group Reference
|
PrivateGroupReference
|
US
|
1
|
|
(0008,0302)
|
Private Creator Reference
|
PrivateCreatorReference
|
LO
|
1
|
|
(0008,0303)
|
Block Identifying Information Status
|
BlockIdentifyingInformationStatus
|
CS
|
1
|
|
(0008,0304)
|
Nonidentifying Private Elements
|
NonidentifyingPrivateElements
|
US
|
1-n
|
|
(0008,0306)
|
Identifying Private Elements
|
IdentifyingPrivateElements
|
US
|
1-n
|
|
(0008,0305)
|
Deidentification Action Sequence
|
DeidentificationActionSequence
|
SQ
|
1
|
|
(0008,0307)
|
Deidentification Action
|
DeidentificationAction
|
CS
|
1
|
|
(0008,1000)
|
Network ID
|
NetworkID
|
AE
|
1
|
RET
|
(0008,1010)
|
Station Name
|
StationName
|
SH
|
1
|
|
(0008,1030)
|
Study Description
|
StudyDescription
|
LO
|
1
|
|
(0008,1032)
|
Procedure Code Sequence
|
ProcedureCodeSequence
|
SQ
|
1
|
|
(0008,103E)
|
Series Description
|
SeriesDescription
|
LO
|
1
|
|
(0008,103F)
|
Series Description Code Sequence
|
SeriesDescriptionCodeSequence
|
SQ
|
1
|
|
(0008,1040)
|
Institutional Department Name
|
InstitutionalDepartmentName
|
LO
|
1
|
|
(0008,1048)
|
Physician(s) of Record
|
PhysiciansOfRecord
|
PN
|
1-n
|
|
(0008,1049)
|
Physician(s) of Record Identification Sequence
|
PhysiciansOfRecordIdentificationSequence
|
SQ
|
1
|
|
(0008,1050)
|
Performing Physician's Name
|
PerformingPhysicianName
|
PN
|
1-n
|
|
(0008,1052)
|
Performing Physician Identification Sequence
|
PerformingPhysicianIdentificationSequence
|
SQ
|
1
|
|
(0008,1060)
|
Name of Physician(s) Reading Study
|
NameOfPhysiciansReadingStudy
|
PN
|
1-n
|
|
(0008,1062)
|
Physician(s) Reading Study Identification Sequence
|
PhysiciansReadingStudyIdentificationSequence
|
SQ
|
1
|
|
(0008,1070)
|
Operators' Name
|
OperatorsName
|
PN
|
1-n
|
|
(0008,1072)
|
Operator Identification Sequence
|
OperatorIdentificationSequence
|
SQ
|
1
|
|
(0008,1080)
|
Admitting Diagnoses Description
|
AdmittingDiagnosesDescription
|
LO
|
1-n
|
|
(0008,1084)
|
Admitting Diagnoses Code Sequence
|
AdmittingDiagnosesCodeSequence
|
SQ
|
1
|
|
(0008,1090)
|
Manufacturer's Model Name
|
ManufacturerModelName
|
LO
|
1
|
|
(0008,1100)
|
Referenced Results Sequence
|
ReferencedResultsSequence
|
SQ
|
1
|
RET
|
(0008,1110)
|
Referenced Study Sequence
|
ReferencedStudySequence
|
SQ
|
1
|
|
(0008,1111)
|
Referenced Performed Procedure Step Sequence
|
ReferencedPerformedProcedureStepSequence
|
SQ
|
1
|
|
(0008,1115)
|
Referenced Series Sequence
|
ReferencedSeriesSequence
|
SQ
|
1
|
|
(0008,1120)
|
Referenced Patient Sequence
|
ReferencedPatientSequence
|
SQ
|
1
|
|
(0008,1125)
|
Referenced Visit Sequence
|
ReferencedVisitSequence
|
SQ
|
1
|
|
(0008,1130)
|
Referenced Overlay Sequence
|
ReferencedOverlaySequence
|
SQ
|
1
|
RET
|
(0008,1134)
|
Referenced Stereometric Instance Sequence
|
ReferencedStereometricInstanceSequence
|
SQ
|
1
|
|
(0008,113A)
|
Referenced Waveform Sequence
|
ReferencedWaveformSequence
|
SQ
|
1
|
|
(0008,1140)
|
Referenced Image Sequence
|
ReferencedImageSequence
|
SQ
|
1
|
|
(0008,1145)
|
Referenced Curve Sequence
|
ReferencedCurveSequence
|
SQ
|
1
|
RET
|
(0008,114A)
|
Referenced Instance Sequence
|
ReferencedInstanceSequence
|
SQ
|
1
|
|
(0008,114B)
|
Referenced Real World Value Mapping Instance Sequence
|
ReferencedRealWorldValueMappingInstanceSequence
|
SQ
|
1
|
|
(0008,1150)
|
Referenced SOP Class UID
|
ReferencedSOPClassUID
|
UI
|
1
|
|
(0008,1155)
|
Referenced SOP Instance UID
|
ReferencedSOPInstanceUID
|
UI
|
1
|
|
(0008,115A)
|
SOP Classes Supported
|
SOPClassesSupported
|
UI
|
1-n
|
|
(0008,1160)
|
Referenced Frame Number
|
ReferencedFrameNumber
|
IS
|
1-n
|
|
(0008,1161)
|
Simple Frame List
|
SimpleFrameList
|
UL
|
1-n
|
|
(0008,1162)
|
Calculated Frame List
|
CalculatedFrameList
|
UL
|
3-3n
|
|
(0008,1163)
|
Time Range
|
TimeRange
|
FD
|
2
|
|
(0008,1164)
|
Frame Extraction Sequence
|
FrameExtractionSequence
|
SQ
|
1
|
|
(0008,1167)
|
Multi-frame Source SOP Instance UID
|
MultiFrameSourceSOPInstanceUID
|
UI
|
1
|
|
(0008,1190)
|
Retrieve URL
|
RetrieveURL
|
UR
|
1
|
|
(0008,1195)
|
Transaction UID
|
TransactionUID
|
UI
|
1
|
|
(0008,1196)
|
Warning Reason
|
WarningReason
|
US
|
1
|
|
(0008,1197)
|
Failure Reason
|
FailureReason
|
US
|
1
|
|
(0008,1198)
|
Failed SOP Sequence
|
FailedSOPSequence
|
SQ
|
1
|
|
(0008,1199)
|
Referenced SOP Sequence
|
ReferencedSOPSequence
|
SQ
|
1
|
|
(0008,119A)
|
Other Failures Sequence
|
OtherFailuresSequence
|
SQ
|
1
|
|
(0008,1200)
|
Studies Containing Other Referenced Instances Sequence
|
StudiesContainingOtherReferencedInstancesSequence
|
SQ
|
1
|
|
(0008,1250)
|
Related Series Sequence
|
RelatedSeriesSequence
|
SQ
|
1
|
|
(0008,2110)
|
Lossy Image Compression (Retired)
|
LossyImageCompressionRetired
|
CS
|
1
|
RET
|
(0008,2111)
|
Derivation Description
|
DerivationDescription
|
ST
|
1
|
|
(0008,2112)
|
Source Image Sequence
|
SourceImageSequence
|
SQ
|
1
|
|
(0008,2120)
|
Stage Name
|
StageName
|
SH
|
1
|
|
(0008,2122)
|
Stage Number
|
StageNumber
|
IS
|
1
|
|
(0008,2124)
|
Number of Stages
|
NumberOfStages
|
IS
|
1
|
|
(0008,2127)
|
View Name
|
ViewName
|
SH
|
1
|
|
(0008,2128)
|
View Number
|
ViewNumber
|
IS
|
1
|
|
(0008,2129)
|
Number of Event Timers
|
NumberOfEventTimers
|
IS
|
1
|
|
(0008,212A)
|
Number of Views in Stage
|
NumberOfViewsInStage
|
IS
|
1
|
|
(0008,2130)
|
Event Elapsed Time(s)
|
EventElapsedTimes
|
DS
|
1-n
|
|
(0008,2132)
|
Event Timer Name(s)
|
EventTimerNames
|
LO
|
1-n
|
|
(0008,2133)
|
Event Timer Sequence
|
EventTimerSequence
|
SQ
|
1
|
|
(0008,2134)
|
Event Time Offset
|
EventTimeOffset
|
FD
|
1
|
|
(0008,2135)
|
Event Code Sequence
|
EventCodeSequence
|
SQ
|
1
|
|
(0008,2142)
|
Start Trim
|
StartTrim
|
IS
|
1
|
|
(0008,2143)
|
Stop Trim
|
StopTrim
|
IS
|
1
|
|
(0008,2144)
|
Recommended Display Frame Rate
|
RecommendedDisplayFrameRate
|
IS
|
1
|
|
(0008,2200)
|
Transducer Position
|
TransducerPosition
|
CS
|
1
|
RET
|
(0008,2204)
|
Transducer Orientation
|
TransducerOrientation
|
CS
|
1
|
RET
|
(0008,2208)
|
Anatomic Structure
|
AnatomicStructure
|
CS
|
1
|
RET
|
(0008,2218)
|
Anatomic Region Sequence
|
AnatomicRegionSequence
|
SQ
|
1
|
|
(0008,2220)
|
Anatomic Region Modifier Sequence
|
AnatomicRegionModifierSequence
|
SQ
|
1
|
|
(0008,2228)
|
Primary Anatomic Structure Sequence
|
PrimaryAnatomicStructureSequence
|
SQ
|
1
|
|
(0008,2229)
|
Anatomic Structure, Space or Region Sequence
|
AnatomicStructureSpaceOrRegionSequence
|
SQ
|
1
|
|
(0008,2230)
|
Primary Anatomic Structure Modifier Sequence
|
PrimaryAnatomicStructureModifierSequence
|
SQ
|
1
|
|
(0008,2240)
|
Transducer Position Sequence
|
TransducerPositionSequence
|
SQ
|
1
|
RET
|
(0008,2242)
|
Transducer Position Modifier Sequence
|
TransducerPositionModifierSequence
|
SQ
|
1
|
RET
|
(0008,2244)
|
Transducer Orientation Sequence
|
TransducerOrientationSequence
|
SQ
|
1
|
RET
|
(0008,2246)
|
Transducer Orientation Modifier Sequence
|
TransducerOrientationModifierSequence
|
SQ
|
1
|
RET
|
(0008,2251)
|
Anatomic Structure Space Or Region Code Sequence (Trial)
|
AnatomicStructureSpaceOrRegionCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,2253)
|
Anatomic Portal Of Entrance Code Sequence (Trial)
|
AnatomicPortalOfEntranceCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,2255)
|
Anatomic Approach Direction Code Sequence (Trial)
|
AnatomicApproachDirectionCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,2256)
|
Anatomic Perspective Description (Trial)
|
AnatomicPerspectiveDescriptionTrial
|
ST
|
1
|
RET
|
(0008,2257)
|
Anatomic Perspective Code Sequence (Trial)
|
AnatomicPerspectiveCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,2258)
|
Anatomic Location Of Examining Instrument Description (Trial)
|
AnatomicLocationOfExaminingInstrumentDescriptionTrial
|
ST
|
1
|
RET
|
(0008,2259)
|
Anatomic Location Of Examining Instrument Code Sequence (Trial)
|
AnatomicLocationOfExaminingInstrumentCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,225A)
|
Anatomic Structure Space Or Region Modifier Code Sequence (Trial)
|
AnatomicStructureSpaceOrRegionModifierCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,225C)
|
On Axis Background Anatomic Structure Code Sequence (Trial)
|
OnAxisBackgroundAnatomicStructureCodeSequenceTrial
|
SQ
|
1
|
RET
|
(0008,3001)
|
Alternate Representation Sequence
|
AlternateRepresentationSequence
|
SQ
|
1
|
|
(0008,3010)
|
Irradiation Event UID
|
IrradiationEventUID
|
UI
|
1-n
|
|
(0008,3011)
|
Source Irradiation Event Sequence
|
SourceIrradiationEventSequence
|
SQ
|
1
|
|
(0008,3012)
|
Radiopharmaceutical Administration Event UID
|
RadiopharmaceuticalAdministrationEventUID
|
UI
|
1
|
|
(0008,4000)
|
Identifying Comments
|
IdentifyingComments
|
LT
|
1
|
RET
|
(0008,9007)
|
Frame Type
|
FrameType
|
CS
|
4
|
|
(0008,9092)
|
Referenced Image Evidence Sequence
|
ReferencedImageEvidenceSequence
|
SQ
|
1
|
|
(0008,9121)
|
Referenced Raw Data Sequence
|
ReferencedRawDataSequence
|
SQ
|
1
|
|
(0008,9123)
|
Creator-Version UID
|
CreatorVersionUID
|
UI
|
1
|
|
(0008,9124)
|
Derivation Image Sequence
|
DerivationImageSequence
|
SQ
|
1
|
|
(0008,9154)
|
Source Image Evidence Sequence
|
SourceImageEvidenceSequence
|
SQ
|
1
|
|
(0008,9205)
|
Pixel Presentation
|
PixelPresentation
|
CS
|
1
|
|
(0008,9206)
|
Volumetric Properties
|
VolumetricProperties
|
CS
|
1
|
|
(0008,9207)
|
Volume Based Calculation Technique
|
VolumeBasedCalculationTechnique
|
CS
|
1
|
|
(0008,9208)
|
Complex Image Component
|
ComplexImageComponent
|
CS
|
1
|
|
(0008,9209)
|
Acquisition Contrast
|
AcquisitionContrast
|
CS
|
1
|
|
(0008,9215)
|
Derivation Code Sequence
|
DerivationCodeSequence
|
SQ
|
1
|
|
(0008,9237)
|
Referenced Presentation State Sequence
|
ReferencedPresentationStateSequence
|
SQ
|
1
|
|
(0008,9410)
|
Referenced Other Plane Sequence
|
ReferencedOtherPlaneSequence
|
SQ
|
1
|
|
(0008,9458)
|
Frame Display Sequence
|
FrameDisplaySequence
|
SQ
|
1
|
|
(0008,9459)
|
Recommended Display Frame Rate in Float
|
RecommendedDisplayFrameRateInFloat
|
FL
|
1
|
|
(0008,9460)
|
Skip Frame Range Flag
|
SkipFrameRangeFlag
|
CS
|
1
|
|
(0010,0010)
|
Patient's Name
|
PatientName
|
PN
|
1
|
|
(0010,0020)
|
Patient ID
|
PatientID
|
LO
|
1
|
|
(0010,0021)
|
Issuer of Patient ID
|
IssuerOfPatientID
|
LO
|
1
|
|
(0010,0022)
|
Type of Patient ID
|
TypeOfPatientID
|
CS
|
1
|
|
(0010,0024)
|
Issuer of Patient ID Qualifiers Sequence
|
IssuerOfPatientIDQualifiersSequence
|
SQ
|
1
|
|
(0010,0026)
|
Source Patient Group Identification Sequence
|
SourcePatientGroupIdentificationSequence
|
SQ
|
1
|
|
(0010,0027)
|
Group of Patients Identification Sequence
|
GroupOfPatientsIdentificationSequence
|
SQ
|
1
|
|
(0010,0028)
|
Subject Relative Position in Image
|
SubjectRelativePositionInImage
|
US
|
3
|
|
(0010,0030)
|
Patient's Birth Date
|
PatientBirthDate
|
DA
|
1
|
|
(0010,0032)
|
Patient's Birth Time
|
PatientBirthTime
|
TM
|
1
|
|
(0010,0033)
|
Patient's Birth Date in Alternative Calendar
|
PatientBirthDateInAlternativeCalendar
|
LO
|
1
|
|
(0010,0034)
|
Patient's Death Date in Alternative Calendar
|
PatientDeathDateInAlternativeCalendar
|
LO
|
1
|
|
(0010,0035)
|
Patient's Alternative Calendar
|
PatientAlternativeCalendar
|
CS
|
1
|
|
(0010,0040)
|
Patient's Sex
|
PatientSex
|
CS
|
1
|
|
(0010,0050)
|
Patient's Insurance Plan Code Sequence
|
PatientInsurancePlanCodeSequence
|
SQ
|
1
|
|
(0010,0101)
|
Patient's Primary Language Code Sequence
|
PatientPrimaryLanguageCodeSequence
|
SQ
|
1
|
|
(0010,0102)
|
Patient's Primary Language Modifier Code Sequence
|
PatientPrimaryLanguageModifierCodeSequence
|
SQ
|
1
|
|
(0010,0200)
|
Quality Control Subject
|
QualityControlSubject
|
CS
|
1
|
|
(0010,0201)
|
Quality Control Subject Type Code Sequence
|
QualityControlSubjectTypeCodeSequence
|
SQ
|
1
|
|
(0010,0212)
|
Strain Description
|
StrainDescription
|
UC
|
1
|
|
(0010,0213)
|
Strain Nomenclature
|
StrainNomenclature
|
LO
|
1
|
|
(0010,0214)
|
Strain Stock Number
|
StrainStockNumber
|
LO
|
1
|
|
(0010,0215)
|
Strain Source Registry Code Sequence
|
StrainSourceRegistryCodeSequence
|
SQ
|
1
|
|
(0010,0216)
|
Strain Stock Sequence
|
StrainStockSequence
|
SQ
|
1
|
|
(0010,0217)
|
Strain Source
|
StrainSource
|
LO
|
1
|
|
(0010,0218)
|
Strain Additional Information
|
StrainAdditionalInformation
|
UT
|
1
|
|
(0010,0219)
|
Strain Code Sequence
|
StrainCodeSequence
|
SQ
|
1
|
|
(0010,1000)
|
Other Patient IDs
|
OtherPatientIDs
|
LO
|
1-n
|
|
(0010,1001)
|
Other Patient Names
|
OtherPatientNames
|
PN
|
1-n
|
|
(0010,1002)
|
Other Patient IDs Sequence
|
OtherPatientIDsSequence
|
SQ
|
1
|
|
(0010,1005)
|
Patient's Birth Name
|
PatientBirthName
|
PN
|
1
|
|
(0010,1010)
|
Patient's Age
|
PatientAge
|
AS
|
1
|
|
(0010,1020)
|
Patient's Size
|
PatientSize
|
DS
|
1
|
|
(0010,1021)
|
Patient's Size Code Sequence
|
PatientSizeCodeSequence
|
SQ
|
1
|
|
(0010,1030)
|
Patient's Weight
|
PatientWeight
|
DS
|
1
|
|
(0010,1040)
|
Patient's Address
|
PatientAddress
|
LO
|
1
|
|
(0010,1050)
|
Insurance Plan Identification
|
InsurancePlanIdentification
|
LO
|
1-n
|
RET
|
(0010,1060)
|
Patient's Mother's Birth Name
|
PatientMotherBirthName
|
PN
|
1
|
|
(0010,1080)
|
Military Rank
|
MilitaryRank
|
LO
|
1
|
|
(0010,1081)
|
Branch of Service
|
BranchOfService
|
LO
|
1
|
|
(0010,1090)
|
Medical Record Locator
|
MedicalRecordLocator
|
LO
|
1
|
|
(0010,1100)
|
Referenced Patient Photo Sequence
|
ReferencedPatientPhotoSequence
|
SQ
|
1
|
|
(0010,2000)
|
Medical Alerts
|
MedicalAlerts
|
LO
|
1-n
|
|
(0010,2110)
|
Allergies
|
Allergies
|
LO
|
1-n
|
|
(0010,2150)
|
Country of Residence
|
CountryOfResidence
|
LO
|
1
|
|
(0010,2152)
|
Region of Residence
|
RegionOfResidence
|
LO
|
1
|
|
(0010,2154)
|
Patient's Telephone Numbers
|
PatientTelephoneNumbers
|
SH
|
1-n
|
|
(0010,2155)
|
Patient's Telecom Information
|
PatientTelecomInformation
|
LT
|
1
|
|
(0010,2160)
|
Ethnic Group
|
EthnicGroup
|
SH
|
1
|
|
(0010,2180)
|
Occupation
|
Occupation
|
SH
|
1
|
|
(0010,21A0)
|
Smoking Status
|
SmokingStatus
|
CS
|
1
|
|
(0010,21B0)
|
Additional Patient History
|
AdditionalPatientHistory
|
LT
|
1
|
|
(0010,21C0)
|
Pregnancy Status
|
PregnancyStatus
|
US
|
1
|
|
(0010,21D0)
|
Last Menstrual Date
|
LastMenstrualDate
|
DA
|
1
|
|
(0010,21F0)
|
Patient's Religious Preference
|
PatientReligiousPreference
|
LO
|
1
|
|
(0010,2201)
|
Patient Species Description
|
PatientSpeciesDescription
|
LO
|
1
|
|
(0010,2202)
|
Patient Species Code Sequence
|
PatientSpeciesCodeSequence
|
SQ
|
1
|
|
(0010,2203)
|
Patient's Sex Neutered
|
PatientSexNeutered
|
CS
|
1
|
|
(0010,2210)
|
Anatomical Orientation Type
|
AnatomicalOrientationType
|
CS
|
1
|
|
(0010,2292)
|
Patient Breed Description
|
PatientBreedDescription
|
LO
|
1
|
|
(0010,2293)
|
Patient Breed Code Sequence
|
PatientBreedCodeSequence
|
SQ
|
1
|
|
(0010,2294)
|
Breed Registration Sequence
|
BreedRegistrationSequence
|
SQ
|
1
|
|
(0010,2295)
|
Breed Registration Number
|
BreedRegistrationNumber
|
LO
|
1
|
|
(0010,2296)
|
Breed Registry Code Sequence
|
BreedRegistryCodeSequence
|
SQ
|
1
|
|
(0010,2297)
|
Responsible Person
|
ResponsiblePerson
|
PN
|
1
|
|
(0010,2298)
|
Responsible Person Role
|
ResponsiblePersonRole
|
CS
|
1
|
|
(0010,2299)
|
Responsible Organization
|
ResponsibleOrganization
|
LO
|
1
|
|
(0010,4000)
|
Patient Comments
|
PatientComments
|
LT
|
1
|
|
(0010,9431)
|
Examined Body Thickness
|
ExaminedBodyThickness
|
FL
|
1
|
|
(0012,0010)
|
Clinical Trial Sponsor Name
|
ClinicalTrialSponsorName
|
LO
|
1
|
|
(0012,0020)
|
Clinical Trial Protocol ID
|
ClinicalTrialProtocolID
|
LO
|
1
|
|
(0012,0021)
|
Clinical Trial Protocol Name
|
ClinicalTrialProtocolName
|
LO
|
1
|
|
(0012,0030)
|
Clinical Trial Site ID
|
ClinicalTrialSiteID
|
LO
|
1
|
|
(0012,0031)
|
Clinical Trial Site Name
|
ClinicalTrialSiteName
|
LO
|
1
|
|
(0012,0040)
|
Clinical Trial Subject ID
|
ClinicalTrialSubjectID
|
LO
|
1
|
|
(0012,0042)
|
Clinical Trial Subject Reading ID
|
ClinicalTrialSubjectReadingID
|
LO
|
1
|
|
(0012,0050)
|
Clinical Trial Time Point ID
|
ClinicalTrialTimePointID
|
LO
|
1
|
|
(0012,0051)
|
Clinical Trial Time Point Description
|
ClinicalTrialTimePointDescription
|
ST
|
1
|
|
(0012,0060)
|
Clinical Trial Coordinating Center Name
|
ClinicalTrialCoordinatingCenterName
|
LO
|
1
|
|
(0012,0062)
|
Patient Identity Removed
|
PatientIdentityRemoved
|
CS
|
1
|
|
(0012,0063)
|
De-identification Method
|
DeidentificationMethod
|
LO
|
1-n
|
|
(0012,0064)
|
De-identification Method Code Sequence
|
DeidentificationMethodCodeSequence
|
SQ
|
1
|
|
(0012,0071)
|
Clinical Trial Series ID
|
ClinicalTrialSeriesID
|
LO
|
1
|
|
(0012,0072)
|
Clinical Trial Series Description
|
ClinicalTrialSeriesDescription
|
LO
|
1
|
|
(0012,0081)
|
Clinical Trial Protocol Ethics Committee Name
|
ClinicalTrialProtocolEthicsCommitteeName
|
LO
|
1
|
|
(0012,0082)
|
Clinical Trial Protocol Ethics Committee Approval Number
|
ClinicalTrialProtocolEthicsCommitteeApprovalNumber
|
LO
|
1
|
|
(0012,0083)
|
Consent for Clinical Trial Use Sequence
|
ConsentForClinicalTrialUseSequence
|
SQ
|
1
|
|
(0012,0084)
|
Distribution Type
|
DistributionType
|
CS
|
1
|
|
(0012,0085)
|
Consent for Distribution Flag
|
ConsentForDistributionFlag
|
CS
|
1
|
|
(0014,0023)
|
CAD File Format
|
CADFileFormat
|
ST
|
1
|
RET
|
(0014,0024)
|
Component Reference System
|
ComponentReferenceSystem
|
ST
|
1
|
RET
|
(0014,0025)
|
Component Manufacturing Procedure
|
ComponentManufacturingProcedure
|
ST
|
1
|
DICONDE
|
(0014,0028)
|
Component Manufacturer
|
ComponentManufacturer
|
ST
|
1
|
DICONDE
|
(0014,0030)
|
Material Thickness
|
MaterialThickness
|
DS
|
1-n
|
DICONDE
|
(0014,0032)
|
Material Pipe Diameter
|
MaterialPipeDiameter
|
DS
|
1-n
|
DICONDE
|
(0014,0034)
|
Material Isolation Diameter
|
MaterialIsolationDiameter
|
DS
|
1-n
|
DICONDE
|
(0014,0042)
|
Material Grade
|
MaterialGrade
|
ST
|
1
|
DICONDE
|
(0014,0044)
|
Material Properties Description
|
MaterialPropertiesDescription
|
ST
|
1
|
DICONDE
|
(0014,0045)
|
Material Properties File Format (Retired)
|
MaterialPropertiesFileFormatRetired
|
ST
|
1
|
RET
|
(0014,0046)
|
Material Notes
|
MaterialNotes
|
LT
|
1
|
DICONDE
|
(0014,0050)
|
Component Shape
|
ComponentShape
|
CS
|
1
|
DICONDE
|
(0014,0052)
|
Curvature Type
|
CurvatureType
|
CS
|
1
|
DICONDE
|
(0014,0054)
|
Outer Diameter
|
OuterDiameter
|
DS
|
1
|
DICONDE
|
(0014,0056)
|
Inner Diameter
|
InnerDiameter
|
DS
|
1
|
DICONDE
|
(0014,0100)
|
Component Welder IDs
|
ComponentWelderIDs
|
LO
|
1-n
|
DICONDE
|
(0014,0101)
|
Secondary Approval Status
|
SecondaryApprovalStatus
|
CS
|
1
|
DICONDE
|
(0014,0102)
|
Secondary Review Date
|
SecondaryReviewDate
|
DA
|
1
|
DICONDE
|
(0014,0103)
|
Secondary Review Time
|
SecondaryReviewTime
|
TM
|
1
|
DICONDE
|
(0014,0104)
|
Secondary Reviewer Name
|
SecondaryReviewerName
|
PN
|
1
|
DICONDE
|
(0014,0105)
|
Repair ID
|
RepairID
|
ST
|
1
|
DICONDE
|
(0014,0106)
|
Multiple Component Approval Sequence
|
MultipleComponentApprovalSequence
|
SQ
|
1
|
DICONDE
|
(0014,0107)
|
Other Approval Status
|
OtherApprovalStatus
|
CS
|
1-n
|
DICONDE
|
(0014,0108)
|
Other Secondary Approval Status
|
OtherSecondaryApprovalStatus
|
CS
|
1-n
|
DICONDE
|
(0014,1010)
|
Actual Environmental Conditions
|
ActualEnvironmentalConditions
|
ST
|
1
|
DICONDE
|
(0014,1020)
|
Expiry Date
|
ExpiryDate
|
DA
|
1
|
DICONDE
|
(0014,1040)
|
Environmental Conditions
|
EnvironmentalConditions
|
ST
|
1
|
DICONDE
|
(0014,2002)
|
Evaluator Sequence
|
EvaluatorSequence
|
SQ
|
1
|
DICONDE
|
(0014,2004)
|
Evaluator Number
|
EvaluatorNumber
|
IS
|
1
|
DICONDE
|
(0014,2006)
|
Evaluator Name
|
EvaluatorName
|
PN
|
1
|
DICONDE
|
(0014,2008)
|
Evaluation Attempt
|
EvaluationAttempt
|
IS
|
1
|
DICONDE
|
(0014,2012)
|
Indication Sequence
|
IndicationSequence
|
SQ
|
1
|
DICONDE
|
(0014,2014)
|
Indication Number
|
IndicationNumber
|
IS
|
1
|
DICONDE
|
(0014,2016)
|
Indication Label
|
IndicationLabel
|
SH
|
1
|
DICONDE
|
(0014,2018)
|
Indication Description
|
IndicationDescription
|
ST
|
1
|
DICONDE
|
(0014,201A)
|
Indication Type
|
IndicationType
|
CS
|
1-n
|
DICONDE
|
(0014,201C)
|
Indication Disposition
|
IndicationDisposition
|
CS
|
1
|
DICONDE
|
(0014,201E)
|
Indication ROI Sequence
|
IndicationROISequence
|
SQ
|
1
|
DICONDE
|
(0014,2030)
|
Indication Physical Property Sequence
|
IndicationPhysicalPropertySequence
|
SQ
|
1
|
DICONDE
|
(0014,2032)
|
Property Label
|
PropertyLabel
|
SH
|
1
|
DICONDE
|
(0014,2202)
|
Coordinate System Number of Axes
|
CoordinateSystemNumberOfAxes
|
IS
|
1
|
DICONDE
|
(0014,2204)
|
Coordinate System Axes Sequence
|
CoordinateSystemAxesSequence
|
SQ
|
1
|
DICONDE
|
(0014,2206)
|
Coordinate System Axis Description
|
CoordinateSystemAxisDescription
|
ST
|
1
|
DICONDE
|
(0014,2208)
|
Coordinate System Data Set Mapping
|
CoordinateSystemDataSetMapping
|
CS
|
1
|
DICONDE
|
(0014,220A)
|
Coordinate System Axis Number
|
CoordinateSystemAxisNumber
|
IS
|
1
|
DICONDE
|
(0014,220C)
|
Coordinate System Axis Type
|
CoordinateSystemAxisType
|
CS
|
1
|
DICONDE
|
(0014,220E)
|
Coordinate System Axis Units
|
CoordinateSystemAxisUnits
|
CS
|
1
|
DICONDE
|
(0014,2210)
|
Coordinate System Axis Values
|
CoordinateSystemAxisValues
|
OB
|
1
|
DICONDE
|
(0014,2220)
|
Coordinate System Transform Sequence
|
CoordinateSystemTransformSequence
|
SQ
|
1
|
DICONDE
|
(0014,2222)
|
Transform Description
|
TransformDescription
|
ST
|
1
|
DICONDE
|
(0014,2224)
|
Transform Number of Axes
|
TransformNumberOfAxes
|
IS
|
1
|
DICONDE
|
(0014,2226)
|
Transform Order of Axes
|
TransformOrderOfAxes
|
IS
|
1-n
|
DICONDE
|
(0014,2228)
|
Transformed Axis Units
|
TransformedAxisUnits
|
CS
|
1
|
DICONDE
|
(0014,222A)
|
Coordinate System Transform Rotation and Scale Matrix
|
CoordinateSystemTransformRotationAndScaleMatrix
|
DS
|
1-n
|
DICONDE
|
(0014,222C)
|
Coordinate System Transform Translation Matrix
|
CoordinateSystemTransformTranslationMatrix
|
DS
|
1-n
|
DICONDE
|
(0014,3011)
|
Internal Detector Frame Time
|
InternalDetectorFrameTime
|
DS
|
1
|
DICONDE
|
(0014,3012)
|
Number of Frames Integrated
|
NumberOfFramesIntegrated
|
DS
|
1
|
DICONDE
|
(0014,3020)
|
Detector Temperature Sequence
|
DetectorTemperatureSequence
|
SQ
|
1
|
DICONDE
|
(0014,3022)
|
Sensor Name
|
SensorName
|
ST
|
1
|
DICONDE
|
(0014,3024)
|
Horizontal Offset of Sensor
|
HorizontalOffsetOfSensor
|
DS
|
1
|
DICONDE
|
(0014,3026)
|
Vertical Offset of Sensor
|
VerticalOffsetOfSensor
|
DS
|
1
|
DICONDE
|
(0014,3028)
|
Sensor Temperature
|
SensorTemperature
|
DS
|
1
|
DICONDE
|
(0014,3040)
|
Dark Current Sequence
|
DarkCurrentSequence
|
SQ
|
1
|
DICONDE
|
(0014,3050)
|
Dark Current Counts
|
DarkCurrentCounts
|
OB or OW
|
1
|
DICONDE
|
(0014,3060)
|
Gain Correction Reference Sequence
|
GainCorrectionReferenceSequence
|
SQ
|
1
|
DICONDE
|
(0014,3070)
|
Air Counts
|
AirCounts
|
OB or OW
|
1
|
DICONDE
|
(0014,3071)
|
KV Used in Gain Calibration
|
KVUsedInGainCalibration
|
DS
|
1
|
DICONDE
|
(0014,3072)
|
MA Used in Gain Calibration
|
MAUsedInGainCalibration
|
DS
|
1
|
DICONDE
|
(0014,3073)
|
Number of Frames Used for Integration
|
NumberOfFramesUsedForIntegration
|
DS
|
1
|
DICONDE
|
(0014,3074)
|
Filter Material Used in Gain Calibration
|
FilterMaterialUsedInGainCalibration
|
LO
|
1
|
DICONDE
|
(0014,3075)
|
Filter Thickness Used in Gain Calibration
|
FilterThicknessUsedInGainCalibration
|
DS
|
1
|
DICONDE
|
(0014,3076)
|
Date of Gain Calibration
|
DateOfGainCalibration
|
DA
|
1
|
DICONDE
|
(0014,3077)
|
Time of Gain Calibration
|
TimeOfGainCalibration
|
TM
|
1
|
DICONDE
|
(0014,3080)
|
Bad Pixel Image
|
BadPixelImage
|
OB
|
1
|
DICONDE
|
(0014,3099)
|
Calibration Notes
|
CalibrationNotes
|
LT
|
1
|
DICONDE
|
(0014,4002)
|
Pulser Equipment Sequence
|
PulserEquipmentSequence
|
SQ
|
1
|
DICONDE
|
(0014,4004)
|
Pulser Type
|
PulserType
|
CS
|
1
|
DICONDE
|
(0014,4006)
|
Pulser Notes
|
PulserNotes
|
LT
|
1
|
DICONDE
|
(0014,4008)
|
Receiver Equipment Sequence
|
ReceiverEquipmentSequence
|
SQ
|
1
|
DICONDE
|
(0014,400A)
|
Amplifier Type
|
AmplifierType
|
CS
|
1
|
DICONDE
|
(0014,400C)
|
Receiver Notes
|
ReceiverNotes
|
LT
|
1
|
DICONDE
|
(0014,400E)
|
Pre-Amplifier Equipment Sequence
|
PreAmplifierEquipmentSequence
|
SQ
|
1
|
DICONDE
|
(0014,400F)
|
Pre-Amplifier Notes
|
PreAmplifierNotes
|
LT
|
1
|
DICONDE
|
(0014,4010)
|
Transmit Transducer Sequence
|
TransmitTransducerSequence
|
SQ
|
1
|
DICONDE
|
(0014,4011)
|
Receive Transducer Sequence
|
ReceiveTransducerSequence
|
SQ
|
1
|
DICONDE
|
(0014,4012)
|
Number of Elements
|
NumberOfElements
|
US
|
1
|
DICONDE
|
(0014,4013)
|
Element Shape
|
ElementShape
|
CS
|
1
|
DICONDE
|
(0014,4014)
|
Element Dimension A
|
ElementDimensionA
|
DS
|
1
|
DICONDE
|
(0014,4015)
|
Element Dimension B
|
ElementDimensionB
|
DS
|
1
|
DICONDE
|
(0014,4016)
|
Element Pitch A
|
ElementPitchA
|
DS
|
1
|
DICONDE
|
(0014,4017)
|
Measured Beam Dimension A
|
MeasuredBeamDimensionA
|
DS
|
1
|
DICONDE
|
(0014,4018)
|
Measured Beam Dimension B
|
MeasuredBeamDimensionB
|
DS
|
1
|
DICONDE
|
(0014,4019)
|
Location of Measured Beam Diameter
|
LocationOfMeasuredBeamDiameter
|
DS
|
1
|
DICONDE
|
(0014,401A)
|
Nominal Frequency
|
NominalFrequency
|
DS
|
1
|
DICONDE
|
(0014,401B)
|
Measured Center Frequency
|
MeasuredCenterFrequency
|
DS
|
1
|
DICONDE
|
(0014,401C)
|
Measured Bandwidth
|
MeasuredBandwidth
|
DS
|
1
|
DICONDE
|
(0014,401D)
|
Element Pitch B
|
ElementPitchB
|
DS
|
1
|
DICONDE
|
(0014,4020)
|
Pulser Settings Sequence
|
PulserSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4022)
|
Pulse Width
|
PulseWidth
|
DS
|
1
|
DICONDE
|
(0014,4024)
|
Excitation Frequency
|
ExcitationFrequency
|
DS
|
1
|
DICONDE
|
(0014,4026)
|
Modulation Type
|
ModulationType
|
CS
|
1
|
DICONDE
|
(0014,4028)
|
Damping
|
Damping
|
DS
|
1
|
DICONDE
|
(0014,4030)
|
Receiver Settings Sequence
|
ReceiverSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4031)
|
Acquired Soundpath Length
|
AcquiredSoundpathLength
|
DS
|
1
|
DICONDE
|
(0014,4032)
|
Acquisition Compression Type
|
AcquisitionCompressionType
|
CS
|
1
|
DICONDE
|
(0014,4033)
|
Acquisition Sample Size
|
AcquisitionSampleSize
|
IS
|
1
|
DICONDE
|
(0014,4034)
|
Rectifier Smoothing
|
RectifierSmoothing
|
DS
|
1
|
DICONDE
|
(0014,4035)
|
DAC Sequence
|
DACSequence
|
SQ
|
1
|
DICONDE
|
(0014,4036)
|
DAC Type
|
DACType
|
CS
|
1
|
DICONDE
|
(0014,4038)
|
DAC Gain Points
|
DACGainPoints
|
DS
|
1-n
|
DICONDE
|
(0014,403A)
|
DAC Time Points
|
DACTimePoints
|
DS
|
1-n
|
DICONDE
|
(0014,403C)
|
DAC Amplitude
|
DACAmplitude
|
DS
|
1-n
|
DICONDE
|
(0014,4040)
|
Pre-Amplifier Settings Sequence
|
PreAmplifierSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4050)
|
Transmit Transducer Settings Sequence
|
TransmitTransducerSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4051)
|
Receive Transducer Settings Sequence
|
ReceiveTransducerSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4052)
|
Incident Angle
|
IncidentAngle
|
DS
|
1
|
DICONDE
|
(0014,4054)
|
Coupling Technique
|
CouplingTechnique
|
ST
|
1
|
DICONDE
|
(0014,4056)
|
Coupling Medium
|
CouplingMedium
|
ST
|
1
|
DICONDE
|
(0014,4057)
|
Coupling Velocity
|
CouplingVelocity
|
DS
|
1
|
DICONDE
|
(0014,4058)
|
Probe Center Location X
|
ProbeCenterLocationX
|
DS
|
1
|
DICONDE
|
(0014,4059)
|
Probe Center Location Z
|
ProbeCenterLocationZ
|
DS
|
1
|
DICONDE
|
(0014,405A)
|
Sound Path Length
|
SoundPathLength
|
DS
|
1
|
DICONDE
|
(0014,405C)
|
Delay Law Identifier
|
DelayLawIdentifier
|
ST
|
1
|
DICONDE
|
(0014,4060)
|
Gate Settings Sequence
|
GateSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4062)
|
Gate Threshold
|
GateThreshold
|
DS
|
1
|
DICONDE
|
(0014,4064)
|
Velocity of Sound
|
VelocityOfSound
|
DS
|
1
|
DICONDE
|
(0014,4070)
|
Calibration Settings Sequence
|
CalibrationSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4072)
|
Calibration Procedure
|
CalibrationProcedure
|
ST
|
1
|
DICONDE
|
(0014,4074)
|
Procedure Version
|
ProcedureVersion
|
SH
|
1
|
DICONDE
|
(0014,4076)
|
Procedure Creation Date
|
ProcedureCreationDate
|
DA
|
1
|
DICONDE
|
(0014,4078)
|
Procedure Expiration Date
|
ProcedureExpirationDate
|
DA
|
1
|
DICONDE
|
(0014,407A)
|
Procedure Last Modified Date
|
ProcedureLastModifiedDate
|
DA
|
1
|
DICONDE
|
(0014,407C)
|
Calibration Time
|
CalibrationTime
|
TM
|
1-n
|
DICONDE
|
(0014,407E)
|
Calibration Date
|
CalibrationDate
|
DA
|
1-n
|
DICONDE
|
(0014,4080)
|
Probe Drive Equipment Sequence
|
ProbeDriveEquipmentSequence
|
SQ
|
1
|
DICONDE
|
(0014,4081)
|
Drive Type
|
DriveType
|
CS
|
1
|
DICONDE
|
(0014,4082)
|
Probe Drive Notes
|
ProbeDriveNotes
|
LT
|
1
|
DICONDE
|
(0014,4083)
|
Drive Probe Sequence
|
DriveProbeSequence
|
SQ
|
1
|
DICONDE
|
(0014,4084)
|
Probe Inductance
|
ProbeInductance
|
DS
|
1
|
DICONDE
|
(0014,4085)
|
Probe Resistance
|
ProbeResistance
|
DS
|
1
|
DICONDE
|
(0014,4086)
|
Receive Probe Sequence
|
ReceiveProbeSequence
|
SQ
|
1
|
DICONDE
|
(0014,4087)
|
Probe Drive Settings Sequence
|
ProbeDriveSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4088)
|
Bridge Resistors
|
BridgeResistors
|
DS
|
1
|
DICONDE
|
(0014,4089)
|
Probe Orientation Angle
|
ProbeOrientationAngle
|
DS
|
1
|
DICONDE
|
(0014,408B)
|
User Selected Gain Y
|
UserSelectedGainY
|
DS
|
1
|
DICONDE
|
(0014,408C)
|
User Selected Phase
|
UserSelectedPhase
|
DS
|
1
|
DICONDE
|
(0014,408D)
|
User Selected Offset X
|
UserSelectedOffsetX
|
DS
|
1
|
DICONDE
|
(0014,408E)
|
User Selected Offset Y
|
UserSelectedOffsetY
|
DS
|
1
|
DICONDE
|
(0014,4091)
|
Channel Settings Sequence
|
ChannelSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,4092)
|
Channel Threshold
|
ChannelThreshold
|
DS
|
1
|
DICONDE
|
(0014,409A)
|
Scanner Settings Sequence
|
ScannerSettingsSequence
|
SQ
|
1
|
DICONDE
|
(0014,409B)
|
Scan Procedure
|
ScanProcedure
|
ST
|
1
|
DICONDE
|
(0014,409C)
|
Translation Rate X
|
TranslationRateX
|
DS
|
1
|
DICONDE
|
(0014,409D)
|
Translation Rate Y
|
TranslationRateY
|
DS
|
1
|
DICONDE
|
(0014,409F)
|
Channel Overlap
|
ChannelOverlap
|
DS
|
1
|
DICONDE
|
(0014,40A0)
|
Image Quality Indicator Type
|
ImageQualityIndicatorType
|
LO
|
1
|
DICONDE
|
(0014,40A1)
|
Image Quality Indicator Material
|
ImageQualityIndicatorMaterial
|
LO
|
1
|
DICONDE
|
(0014,40A2)
|
Image Quality Indicator Size
|
ImageQualityIndicatorSize
|
LO
|
1
|
DICONDE
|
(0014,5002)
|
LINAC Energy
|
LINACEnergy
|
IS
|
1
|
DICONDE
|
(0014,5004)
|
LINAC Output
|
LINACOutput
|
IS
|
1
|
DICONDE
|
(0014,5100)
|
Active Aperture
|
ActiveAperture
|
US
|
1
|
DICONDE
|
(0014,5101)
|
Total Aperture
|
TotalAperture
|
DS
|
1
|
DICONDE
|
(0014,5102)
|
Aperture Elevation
|
ApertureElevation
|
DS
|
1
|
DICONDE
|
(0014,5103)
|
Main Lobe Angle
|
MainLobeAngle
|
DS
|
1
|
DICONDE
|
(0014,5104)
|
Main Roof Angle
|
MainRoofAngle
|
DS
|
1
|
DICONDE
|
(0014,5105)
|
Connector Type
|
ConnectorType
|
CS
|
1
|
DICONDE
|
(0014,5106)
|
Wedge Model Number
|
WedgeModelNumber
|
SH
|
1
|
DICONDE
|
(0014,5107)
|
Wedge Angle Float
|
WedgeAngleFloat
|
DS
|
1
|
DICONDE
|
(0014,5108)
|
Wedge Roof Angle
|
WedgeRoofAngle
|
DS
|
1
|
DICONDE
|
(0014,5109)
|
Wedge Element 1 Position
|
WedgeElement1Position
|
CS
|
1
|
DICONDE
|
(0014,510A)
|
Wedge Material Velocity
|
WedgeMaterialVelocity
|
DS
|
1
|
DICONDE
|
(0014,510B)
|
Wedge Material
|
WedgeMaterial
|
SH
|
1
|
DICONDE
|
(0014,510C)
|
Wedge Offset Z
|
WedgeOffsetZ
|
DS
|
1
|
DICONDE
|
(0014,510D)
|
Wedge Origin Offset X
|
WedgeOriginOffsetX
|
DS
|
1
|
DICONDE
|
(0014,510E)
|
Wedge Time Delay
|
WedgeTimeDelay
|
DS
|
1
|
DICONDE
|
(0014,510F)
|
Wedge Name
|
WedgeName
|
SH
|
1
|
DICONDE
|
(0014,5110)
|
Wedge Manufacturer Name
|
WedgeManufacturerName
|
SH
|
1
|
DICONDE
|
(0014,5111)
|
Wedge Description
|
WedgeDescription
|
LO
|
1
|
DICONDE
|
(0014,5112)
|
Nominal Beam Angle
|
NominalBeamAngle
|
DS
|
1
|
DICONDE
|
(0014,5113)
|
Wedge Offset X
|
WedgeOffsetX
|
DS
|
1
|
DICONDE
|
(0014,5114)
|
Wedge Offset Y
|
WedgeOffsetY
|
DS
|
1
|
DICONDE
|
(0014,5115)
|
Wedge Total Length
|
WedgeTotalLength
|
DS
|
1
|
DICONDE
|
(0014,5116)
|
Wedge In Contact Length
|
WedgeInContactLength
|
DS
|
1
|
DICONDE
|
(0014,5117)
|
Wedge Front Gap
|
WedgeFrontGap
|
DS
|
1
|
DICONDE
|
(0014,5118)
|
Wedge Total Height
|
WedgeTotalHeight
|
DS
|
1
|
DICONDE
|
(0014,5119)
|
Wedge Front Height
|
WedgeFrontHeight
|
DS
|
1
|
DICONDE
|
(0014,511A)
|
Wedge Rear Height
|
WedgeRearHeight
|
DS
|
1
|
DICONDE
|
(0014,511B)
|
Wedge Total Width
|
WedgeTotalWidth
|
DS
|
1
|
DICONDE
|
(0014,511C)
|
Wedge In Contact Width
|
WedgeInContactWidth
|
DS
|
1
|
DICONDE
|
(0014,511D)
|
Wedge Chamfer Height
|
WedgeChamferHeight
|
DS
|
1
|
DICONDE
|
(0014,511E)
|
Wedge Curve
|
WedgeCurve
|
CS
|
1
|
DICONDE
|
(0014,511F)
|
Radius Along the Wedge
|
RadiusAlongWedge
|
DS
|
1
|
DICONDE
|
(0018,0010)
|
Contrast/Bolus Agent
|
ContrastBolusAgent
|
LO
|
1
|
|
(0018,0012)
|
Contrast/Bolus Agent Sequence
|
ContrastBolusAgentSequence
|
SQ
|
1
|
|
(0018,0013)
|
Contrast/Bolus T1 Relaxivity
|
ContrastBolusT1Relaxivity
|
FL
|
1
|
|
(0018,0014)
|
Contrast/Bolus Administration Route Sequence
|
ContrastBolusAdministrationRouteSequence
|
SQ
|
1
|
|
(0018,0015)
|
Body Part Examined
|
BodyPartExamined
|
CS
|
1
|
|
(0018,0020)
|
Scanning Sequence
|
ScanningSequence
|
CS
|
1-n
|
|
(0018,0021)
|
Sequence Variant
|
SequenceVariant
|
CS
|
1-n
|
|
(0018,0022)
|
Scan Options
|
ScanOptions
|
CS
|
1-n
|
|
(0018,0023)
|
MR Acquisition Type
|
MRAcquisitionType
|
CS
|
1
|
|
(0018,0024)
|
Sequence Name
|
SequenceName
|
SH
|
1
|
|
(0018,0025)
|
Angio Flag
|
AngioFlag
|
CS
|
1
|
|
(0018,0026)
|
Intervention Drug Information Sequence
|
InterventionDrugInformationSequence
|
SQ
|
1
|
|
(0018,0027)
|
Intervention Drug Stop Time
|
InterventionDrugStopTime
|
TM
|
1
|
|
(0018,0028)
|
Intervention Drug Dose
|
InterventionDrugDose
|
DS
|
1
|
|
(0018,0029)
|
Intervention Drug Code Sequence
|
InterventionDrugCodeSequence
|
SQ
|
1
|
|
(0018,002A)
|
Additional Drug Sequence
|
AdditionalDrugSequence
|
SQ
|
1
|
|
(0018,0030)
|
Radionuclide
|
Radionuclide
|
LO
|
1-n
|
RET
|
(0018,0031)
|
Radiopharmaceutical
|
Radiopharmaceutical
|
LO
|
1
|
|
(0018,0032)
|
Energy Window Centerline
|
EnergyWindowCenterline
|
DS
|
1
|
RET
|
(0018,0033)
|
Energy Window Total Width
|
EnergyWindowTotalWidth
|
DS
|
1-n
|
RET
|
(0018,0034)
|
Intervention Drug Name
|
InterventionDrugName
|
LO
|
1
|
|
(0018,0035)
|
Intervention Drug Start Time
|
InterventionDrugStartTime
|
TM
|
1
|
|
(0018,0036)
|
Intervention Sequence
|
InterventionSequence
|
SQ
|
1
|
|
(0018,0037)
|
Therapy Type
|
TherapyType
|
CS
|
1
|
RET
|
(0018,0038)
|
Intervention Status
|
InterventionStatus
|
CS
|
1
|
|
(0018,0039)
|
Therapy Description
|
TherapyDescription
|
CS
|
1
|
RET
|
(0018,003A)
|
Intervention Description
|
InterventionDescription
|
ST
|
1
|
|
(0018,0040)
|
Cine Rate
|
CineRate
|
IS
|
1
|
|
(0018,0042)
|
Initial Cine Run State
|
InitialCineRunState
|
CS
|
1
|
|
(0018,0050)
|
Slice Thickness
|
SliceThickness
|
DS
|
1
|
|
(0018,0060)
|
KVP
|
KVP
|
DS
|
1
|
|
(0018,0061)
|
|
|
DS
|
1
|
RET
|
(0018,0070)
|
Counts Accumulated
|
CountsAccumulated
|
IS
|
1
|
|
(0018,0071)
|
Acquisition Termination Condition
|
AcquisitionTerminationCondition
|
CS
|
1
|
|
(0018,0072)
|
Effective Duration
|
EffectiveDuration
|
DS
|
1
|
|
(0018,0073)
|
Acquisition Start Condition
|
AcquisitionStartCondition
|
CS
|
1
|
|
(0018,0074)
|
Acquisition Start Condition Data
|
AcquisitionStartConditionData
|
IS
|
1
|
|
(0018,0075)
|
Acquisition Termination Condition Data
|
AcquisitionTerminationConditionData
|
IS
|
1
|
|
(0018,0080)
|
Repetition Time
|
RepetitionTime
|
DS
|
1
|
|
(0018,0081)
|
Echo Time
|
EchoTime
|
DS
|
1
|
|
(0018,0082)
|
Inversion Time
|
InversionTime
|
DS
|
1
|
|
(0018,0083)
|
Number of Averages
|
NumberOfAverages
|
DS
|
1
|
|
(0018,0084)
|
Imaging Frequency
|
ImagingFrequency
|
DS
|
1
|
|
(0018,0085)
|
Imaged Nucleus
|
ImagedNucleus
|
SH
|
1
|
|
(0018,0086)
|
Echo Number(s)
|
EchoNumbers
|
IS
|
1-n
|
|
(0018,0087)
|
Magnetic Field Strength
|
MagneticFieldStrength
|
DS
|
1
|
|
(0018,0088)
|
Spacing Between Slices
|
SpacingBetweenSlices
|
DS
|
1
|
|
(0018,0089)
|
Number of Phase Encoding Steps
|
NumberOfPhaseEncodingSteps
|
IS
|
1
|
|
(0018,0090)
|
Data Collection Diameter
|
DataCollectionDiameter
|
DS
|
1
|
|
(0018,0091)
|
Echo Train Length
|
EchoTrainLength
|
IS
|
1
|
|
(0018,0093)
|
Percent Sampling
|
PercentSampling
|
DS
|
1
|
|
(0018,0094)
|
Percent Phase Field of View
|
PercentPhaseFieldOfView
|
DS
|
1
|
|
(0018,0095)
|
Pixel Bandwidth
|
PixelBandwidth
|
DS
|
1
|
|
(0018,1000)
|
Device Serial Number
|
DeviceSerialNumber
|
LO
|
1
|
|
(0018,1002)
|
Device UID
|
DeviceUID
|
UI
|
1
|
|
(0018,1003)
|
Device ID
|
DeviceID
|
LO
|
1
|
|
(0018,1004)
|
Plate ID
|
PlateID
|
LO
|
1
|
|
(0018,1005)
|
Generator ID
|
GeneratorID
|
LO
|
1
|
|
(0018,1006)
|
Grid ID
|
GridID
|
LO
|
1
|
|
(0018,1007)
|
Cassette ID
|
CassetteID
|
LO
|
1
|
|
(0018,1008)
|
Gantry ID
|
GantryID
|
LO
|
1
|
|
(0018,1010)
|
Secondary Capture Device ID
|
SecondaryCaptureDeviceID
|
LO
|
1
|
|
(0018,1011)
|
Hardcopy Creation Device ID
|
HardcopyCreationDeviceID
|
LO
|
1
|
RET
|
(0018,1012)
|
Date of Secondary Capture
|
DateOfSecondaryCapture
|
DA
|
1
|
|
(0018,1014)
|
Time of Secondary Capture
|
TimeOfSecondaryCapture
|
TM
|
1
|
|
(0018,1016)
|
Secondary Capture Device Manufacturer
|
SecondaryCaptureDeviceManufacturer
|
LO
|
1
|
|
(0018,1017)
|
Hardcopy Device Manufacturer
|
HardcopyDeviceManufacturer
|
LO
|
1
|
RET
|
(0018,1018)
|
Secondary Capture Device Manufacturer's Model Name
|
SecondaryCaptureDeviceManufacturerModelName
|
LO
|
1
|
|
(0018,1019)
|
Secondary Capture Device Software Versions
|
SecondaryCaptureDeviceSoftwareVersions
|
LO
|
1-n
|
|
(0018,101A)
|
Hardcopy Device Software Version
|
HardcopyDeviceSoftwareVersion
|
LO
|
1-n
|
RET
|
(0018,101B)
|
Hardcopy Device Manufacturer's Model Name
|
HardcopyDeviceManufacturerModelName
|
LO
|
1
|
RET
|
(0018,1020)
|
Software Version(s)
|
SoftwareVersions
|
LO
|
1-n
|
|
(0018,1022)
|
Video Image Format Acquired
|
VideoImageFormatAcquired
|
SH
|
1
|
|
(0018,1023)
|
Digital Image Format Acquired
|
DigitalImageFormatAcquired
|
LO
|
1
|
|
(0018,1030)
|
Protocol Name
|
ProtocolName
|
LO
|
1
|
|
(0018,1040)
|
Contrast/Bolus Route
|
ContrastBolusRoute
|
LO
|
1
|
|
(0018,1041)
|
Contrast/Bolus Volume
|
ContrastBolusVolume
|
DS
|
1
|
|
(0018,1042)
|
Contrast/Bolus Start Time
|
ContrastBolusStartTime
|
TM
|
1
|
|
(0018,1043)
|
Contrast/Bolus Stop Time
|
ContrastBolusStopTime
|
TM
|
1
|
|
(0018,1044)
|
Contrast/Bolus Total Dose
|
ContrastBolusTotalDose
|
DS
|
1
|
|
(0018,1045)
|
Syringe Counts
|
SyringeCounts
|
IS
|
1
|
|
(0018,1046)
|
Contrast Flow Rate
|
ContrastFlowRate
|
DS
|
1-n
|
|
(0018,1047)
|
Contrast Flow Duration
|
ContrastFlowDuration
|
DS
|
1-n
|
|
(0018,1048)
|
Contrast/Bolus Ingredient
|
ContrastBolusIngredient
|
CS
|
1
|
|
(0018,1049)
|
Contrast/Bolus Ingredient Concentration
|
ContrastBolusIngredientConcentration
|
DS
|
1
|
|
(0018,1050)
|
Spatial Resolution
|
SpatialResolution
|
DS
|
1
|
|
(0018,1060)
|
Trigger Time
|
TriggerTime
|
DS
|
1
|
|
(0018,1061)
|
Trigger Source or Type
|
TriggerSourceOrType
|
LO
|
1
|
|
(0018,1062)
|
Nominal Interval
|
NominalInterval
|
IS
|
1
|
|
(0018,1063)
|
Frame Time
|
FrameTime
|
DS
|
1
|
|
(0018,1064)
|
Cardiac Framing Type
|
CardiacFramingType
|
LO
|
1
|
|
(0018,1065)
|
Frame Time Vector
|
FrameTimeVector
|
DS
|
1-n
|
|
(0018,1066)
|
Frame Delay
|
FrameDelay
|
DS
|
1
|
|
(0018,1067)
|
Image Trigger Delay
|
ImageTriggerDelay
|
DS
|
1
|
|
(0018,1068)
|
Multiplex Group Time Offset
|
MultiplexGroupTimeOffset
|
DS
|
1
|
|
(0018,1069)
|
Trigger Time Offset
|
TriggerTimeOffset
|
DS
|
1
|
|
(0018,106A)
|
Synchronization Trigger
|
SynchronizationTrigger
|
CS
|
1
|
|
(0018,106C)
|
Synchronization Channel
|
SynchronizationChannel
|
US
|
2
|
|
(0018,106E)
|
Trigger Sample Position
|
TriggerSamplePosition
|
UL
|
1
|
|
(0018,1070)
|
Radiopharmaceutical Route
|
RadiopharmaceuticalRoute
|
LO
|
1
|
|
(0018,1071)
|
Radiopharmaceutical Volume
|
RadiopharmaceuticalVolume
|
DS
|
1
|
|
(0018,1072)
|
Radiopharmaceutical Start Time
|
RadiopharmaceuticalStartTime
|
TM
|
1
|
|
(0018,1073)
|
Radiopharmaceutical Stop Time
|
RadiopharmaceuticalStopTime
|
TM
|
1
|
|
(0018,1074)
|
Radionuclide Total Dose
|
RadionuclideTotalDose
|
DS
|
1
|
|
(0018,1075)
|
Radionuclide Half Life
|
RadionuclideHalfLife
|
DS
|
1
|
|
(0018,1076)
|
Radionuclide Positron Fraction
|
RadionuclidePositronFraction
|
DS
|
1
|
|
(0018,1077)
|
Radiopharmaceutical Specific Activity
|
RadiopharmaceuticalSpecificActivity
|
DS
|
1
|
|
(0018,1078)
|
Radiopharmaceutical Start DateTime
|
RadiopharmaceuticalStartDateTime
|
DT
|
1
|
|
(0018,1079)
|
Radiopharmaceutical Stop DateTime
|
RadiopharmaceuticalStopDateTime
|
DT
|
1
|
|
(0018,1080)
|
Beat Rejection Flag
|
BeatRejectionFlag
|
CS
|
1
|
|
(0018,1081)
|
Low R-R Value
|
LowRRValue
|
IS
|
1
|
|
(0018,1082)
|
High R-R Value
|
HighRRValue
|
IS
|
1
|
|
(0018,1083)
|
Intervals Acquired
|
IntervalsAcquired
|
IS
|
1
|
|
(0018,1084)
|
Intervals Rejected
|
IntervalsRejected
|
IS
|
1
|
|
(0018,1085)
|
PVC Rejection
|
PVCRejection
|
LO
|
1
|
|
(0018,1086)
|
Skip Beats
|
SkipBeats
|
IS
|
1
|
|
(0018,1088)
|
Heart Rate
|
HeartRate
|
IS
|
1
|
|
(0018,1090)
|
Cardiac Number of Images
|
CardiacNumberOfImages
|
IS
|
1
|
|
(0018,1094)
|
Trigger Window
|
TriggerWindow
|
IS
|
1
|
|
(0018,1100)
|
Reconstruction Diameter
|
ReconstructionDiameter
|
DS
|
1
|
|
(0018,1110)
|
Distance Source to Detector
|
DistanceSourceToDetector
|
DS
|
1
|
|
(0018,1111)
|
Distance Source to Patient
|
DistanceSourceToPatient
|
DS
|
1
|
|
(0018,1114)
|
Estimated Radiographic Magnification Factor
|
EstimatedRadiographicMagnificationFactor
|
DS
|
1
|
|
(0018,1120)
|
Gantry/Detector Tilt
|
GantryDetectorTilt
|
DS
|
1
|
|
(0018,1121)
|
Gantry/Detector Slew
|
GantryDetectorSlew
|
DS
|
1
|
|
(0018,1130)
|
Table Height
|
TableHeight
|
DS
|
1
|
|
(0018,1131)
|
Table Traverse
|
TableTraverse
|
DS
|
1
|
|
(0018,1134)
|
Table Motion
|
TableMotion
|
CS
|
1
|
|
(0018,1135)
|
Table Vertical Increment
|
TableVerticalIncrement
|
DS
|
1-n
|
|
(0018,1136)
|
Table Lateral Increment
|
TableLateralIncrement
|
DS
|
1-n
|
|
(0018,1137)
|
Table Longitudinal Increment
|
TableLongitudinalIncrement
|
DS
|
1-n
|
|
(0018,1138)
|
Table Angle
|
TableAngle
|
DS
|
1
|
|
(0018,113A)
|
Table Type
|
TableType
|
CS
|
1
|
|
(0018,1140)
|
Rotation Direction
|
RotationDirection
|
CS
|
1
|
|
(0018,1141)
|
Angular Position
|
AngularPosition
|
DS
|
1
|
RET
|
(0018,1142)
|
Radial Position
|
RadialPosition
|
DS
|
1-n
|
|
(0018,1143)
|
Scan Arc
|
ScanArc
|
DS
|
1
|
|
(0018,1144)
|
Angular Step
|
AngularStep
|
DS
|
1
|
|
(0018,1145)
|
Center of Rotation Offset
|
CenterOfRotationOffset
|
DS
|
1
|
|
(0018,1146)
|
Rotation Offset
|
RotationOffset
|
DS
|
1-n
|
RET
|
(0018,1147)
|
Field of View Shape
|
FieldOfViewShape
|
CS
|
1
|
|
(0018,1149)
|
Field of View Dimension(s)
|
FieldOfViewDimensions
|
IS
|
1-2
|
|
(0018,1150)
|
Exposure Time
|
ExposureTime
|
IS
|
1
|
|
(0018,1151)
|
X-Ray Tube Current
|
XRayTubeCurrent
|
IS
|
1
|
|
(0018,1152)
|
Exposure
|
Exposure
|
IS
|
1
|
|
(0018,1153)
|
Exposure in µAs
|
ExposureInuAs
|
IS
|
1
|
|
(0018,1154)
|
Average Pulse Width
|
AveragePulseWidth
|
DS
|
1
|
|
(0018,1155)
|
Radiation Setting
|
RadiationSetting
|
CS
|
1
|
|
(0018,1156)
|
Rectification Type
|
RectificationType
|
CS
|
1
|
|
(0018,115A)
|
Radiation Mode
|
RadiationMode
|
CS
|
1
|
|
(0018,115E)
|
Image and Fluoroscopy Area Dose Product
|
ImageAndFluoroscopyAreaDoseProduct
|
DS
|
1
|
|
(0018,1160)
|
Filter Type
|
FilterType
|
SH
|
1
|
|
(0018,1161)
|
Type of Filters
|
TypeOfFilters
|
LO
|
1-n
|
|
(0018,1162)
|
Intensifier Size
|
IntensifierSize
|
DS
|
1
|
|
(0018,1164)
|
Imager Pixel Spacing
|
ImagerPixelSpacing
|
DS
|
2
|
|
(0018,1166)
|
Grid
|
Grid
|
CS
|
1-n
|
|
(0018,1170)
|
Generator Power
|
GeneratorPower
|
IS
|
1
|
|
(0018,1180)
|
Collimator/grid Name
|
CollimatorGridName
|
SH
|
1
|
|
(0018,1181)
|
Collimator Type
|
CollimatorType
|
CS
|
1
|
|
(0018,1182)
|
Focal Distance
|
FocalDistance
|
IS
|
1-2
|
|
(0018,1183)
|
X Focus Center
|
XFocusCenter
|
DS
|
1-2
|
|
(0018,1184)
|
Y Focus Center
|
YFocusCenter
|
DS
|
1-2
|
|
(0018,1190)
|
Focal Spot(s)
|
FocalSpots
|
DS
|
1-n
|
|
(0018,1191)
|
Anode Target Material
|
AnodeTargetMaterial
|
CS
|
1
|
|
(0018,11A0)
|
Body Part Thickness
|
BodyPartThickness
|
DS
|
1
|
|
(0018,11A2)
|
Compression Force
|
CompressionForce
|
DS
|
1
|
|
(0018,11A4)
|
Paddle Description
|
PaddleDescription
|
LO
|
1
|
|
(0018,1200)
|
Date of Last Calibration
|
DateOfLastCalibration
|
DA
|
1-n
|
|
(0018,1201)
|
Time of Last Calibration
|
TimeOfLastCalibration
|
TM
|
1-n
|
|
(0018,1202)
|
DateTime of Last Calibration
|
DateTimeOfLastCalibration
|
DT
|
1
|
|
(0018,1210)
|
Convolution Kernel
|
ConvolutionKernel
|
SH
|
1-n
|
|
(0018,1240)
|
Upper/Lower Pixel Values
|
UpperLowerPixelValues
|
IS
|
1-n
|
RET
|
(0018,1242)
|
Actual Frame Duration
|
ActualFrameDuration
|
IS
|
1
|
|
(0018,1243)
|
Count Rate
|
CountRate
|
IS
|
1
|
|
(0018,1244)
|
Preferred Playback Sequencing
|
PreferredPlaybackSequencing
|
US
|
1
|
|
(0018,1250)
|
Receive Coil Name
|
ReceiveCoilName
|
SH
|
1
|
|
(0018,1251)
|
Transmit Coil Name
|
TransmitCoilName
|
SH
|
1
|
|
(0018,1260)
|
Plate Type
|
PlateType
|
SH
|
1
|
|
(0018,1261)
|
Phosphor Type
|
PhosphorType
|
LO
|
1
|
|
(0018,1271)
|
Water Equivalent Diameter
|
WaterEquivalentDiameter
|
FD
|
1
|
|
(0018,1272)
|
Water Equivalent Diameter Calculation Method Code Sequence
|
WaterEquivalentDiameterCalculationMethodCodeSequence
|
SQ
|
1
|
|
(0018,1300)
|
Scan Velocity
|
ScanVelocity
|
DS
|
1
|
|
(0018,1301)
|
Whole Body Technique
|
WholeBodyTechnique
|
CS
|
1-n
|
|
(0018,1302)
|
Scan Length
|
ScanLength
|
IS
|
1
|
|
(0018,1310)
|
Acquisition Matrix
|
AcquisitionMatrix
|
US
|
4
|
|
(0018,1312)
|
In-plane Phase Encoding Direction
|
InPlanePhaseEncodingDirection
|
CS
|
1
|
|
(0018,1314)
|
Flip Angle
|
FlipAngle
|
|