Vascular Ultrasound Report Templates 

TID 5100 Vascular Ultrasound Report

This is the template for the root the content tree for the vascular ultrasound procedure report.

Type:

Extensible

Order:

Significant

Table TID 5100. Vascular Ultrasound Report

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (125100, DCM, "Vascular Ultrasound Procedure Report")

1

M

2

>

HAS OBS CONTEXT

CODE

EV (R-40FB8, SRT, "Temporal periods Relating to Procedure")

1

U

DCID 12102 “Temporal Periods Relating to Procedure or Therapy”

3

>

HAS CONCEPT MOD

INCLUDE

DTID 1204 “Language of Content Item and Descendants”

1

U

4

>

HAS OBS CONTEXT

INCLUDE

DTID 1001 “Observation Context”

1

M

5

>

CONTAINS

INCLUDE

DTID 5101 “Vascular Patient Characteristics”

1

U

6

>

CONTAINS

CONTAINER

EV (111028, DCM, "Image Library")

1

U

7

>>

CONTAINS

IMAGE

No purpose of reference

1-n

M

8

>

CONTAINS

INCLUDE

DTID 5102 “Vascular Procedure Summary Section”

1

U

9

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-40501, SRT, "Blood Vessel of Head")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12105 “Intracranial Cerebral Vessels”

10

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-40501, SRT, "Blood Vessel of Head")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12105 “Intracranial Cerebral Vessels”

11

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-40501, SRT, "Blood Vessel of Head")

$SectionLaterality = EV (G-A103, SRT, "Unilateral")

$Anatomy = DCID 12106 “Intracranial Cerebral Vessels (unilateral)”

12

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-45005, SRT, "Artery of neck")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12104 “Extracranial Arteries”

$AnatomyRatio = DCID 12123 “Carotid Ratios”

13

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-45005, SRT, "Artery of neck")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12104 “Extracranial Arteries”

$AnatomyRatio = DCID 12123 “Carotid Ratios”

14

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-47040, SRT, "Artery of Lower Extremity")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12109 “Lower Extremity Arteries”

15

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-47040, SRT, "Artery of Lower Extremity")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12109 “Lower Extremity Arteries”

16

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-49403, SRT, "Vein of Lower Extremity")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12110 “Lower Extremity Veins”

17

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-49403, SRT, "Vein of Lower Extremity")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12110 “Lower Extremity Veins”

18

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-47020, SRT, "Artery Of Upper Extremity")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12107 “Upper Extremity Arteries”

19

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-47020, SRT, "Artery Of Upper Extremity")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12107 “Upper Extremity Arteries”

20

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-49103, SRT, "Vein Of Upper Extremity")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12108 “Upper Extremity Veins”

21

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-49103, SRT, "Vein Of Upper Extremity")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12108 “Upper Extremity Veins”

22

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-71019, SRT, "Vascular Structure Of Kidney")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12115 “Renal Vessels”

$AnatomyRatio = DCID 12124 “Renal Ratios”

23

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-71019, SRT, "Vascular Structure Of Kidney")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12115 “Renal Vessels”

$AnatomyRatio = DCID 12124 “Renal Ratios”

24

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-46002, SRT, "Artery of Abdomen")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12111 “Abdominal Arteries (lateral)”

25

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-46002, SRT, "Artery of Abdomen")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12111 “Abdominal Arteries (lateral)”

26

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-46002, SRT, "Artery of Abdomen")

$SectionLaterality = EV (G-A103, SRT, "Unilateral")

$Anatomy = DCID 12112 “Abdominal Arteries (unilateral)”

27

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-487A0, SRT, "Vein of Abdomen")

$SectionLaterality = EV (G-A101, SRT, "Left")

$Anatomy = DCID 12113 “Abdominal Veins (lateral)”

28

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-487A0, SRT, "Vein of Abdomen")

$SectionLaterality = EV (G-A100, SRT, "Right")

$Anatomy = DCID 12113 “Abdominal Veins (lateral)”

29

>

CONTAINS

INCLUDE

DTID 5103 “Vascular Ultrasound Section”

1

U

$SectionScope = DT (T-487A0, SRT, "Vein of Abdomen")

$SectionLaterality = EV (G-A103, SRT, "Unilateral")

$Anatomy = DCID 12114 “Abdominal Veins (unilateral)”

30

>

CONTAINS

INCLUDE

DTID 5105 “Ultrasound Graft Section”

1

U


TID 5101 Vascular Patient Characteristics

Patient Characteristic concepts in this template, which may replicate attributes in the Patient Study Module, are included here as possible targets of by-reference relationships from other content items in the SR tree.

Note

Several of the concepts in this template duplicate concepts in TID 1007 “Subject Context, Patient”. The difference in use is that this template has those concepts as primary observations of the patient, while in TID 1007 “Subject Context, Patient” the concepts are used to set (or reset) the context for other observations.

Type:

Extensible

Order:

Significant

Table TID 5101. Vascular Patient Characteristics

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (121118, DCM, "Patient Characteristics")

1

M

2

>

CONTAINS

NUM

EV (121033, DCM, "Subject Age")

1

U

UNITS = DCID 7456 “Units of Measure for Age”

3

>

CONTAINS

CODE

EV (121032, DCM, "Subject Sex")

1

U

DCID 7455 “Sex”

4

>

CONTAINS

NUM

EV (8867-4, LN, "Heart Rate")

1

U

5

>

CONTAINS

NUM

EV (F-008EC, SRT, "Systolic Blood Pressure")

1

U

6

>

CONTAINS

NUM

EV (F-008ED, SRT, "Diastolic Blood Pressure")

1

U


TID 5102 Vascular Procedure Summary Section

Comments and observations of the procedure of immediate clinical interest.

Type:

Extensible

Order:

Significant

Table TID 5102. Vascular Procedure Summary Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

DT (121111, DCM, "Summary")

1

M

2

>

CONTAINS

TEXT

DCID 12101 “Vascular Summary”

1-n

M


TID 5103 Vascular Ultrasound Section

Sections of a vascular ultrasound report are section containers of an anatomic region consisting of measurement group containers that contain the measurements.

Table TID 5103. Parameters

Parameter Name

Parameter Usage

$SectionScope

The concept name of the section heading modifier

$SectionLaterality

The laterality (if any) of the anatomy in this section heading

$Anatomy

The concept name of the vascular anatomy

$AnatomyRatio

The concept name of anatomy-coordinated ratio concepts


Type:

Extensible

Order:

Significant

Table TID 5103. Vascular Ultrasound Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

DT (121070, DCM, "Findings")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (G-C0E3, SRT, "Finding Site")

1

M

$SectionScope

3

>

HAS CONCEPT MOD

CODE

EV (G-C171, SRT, "Laterality")

1

M

$SectionLaterality

4

>

CONTAINS

INCLUDE

DTID 5104 “Vascular Ultrasound Measurement Group”

1-n

M

$AnatomyGroup = $Anatomy

5

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = $AnatomyRatio


TID 5104 Vascular Ultrasound Measurement Group

This template is an anatomy specific container of measurements.

Table TID 5104. Parameters

Parameter Name

Parameter Usage

$AnatomyGroup

The concept name of the vascular anatomy


Type:

Extensible

Order:

Significant

Table TID 5104. Vascular Ultrasound Measurement Group

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

$AnatomyGroup

1

M

2

>

HAS CONCEPT MOD

CODE

EV (G-A1F8, SRT, "Topographical Modifier")

1

U

DCID 12116 “Vessel Segment Modifiers”

3

>

HAS CONCEPT MOD

CODE

EV (125101, DCM, "Vessel Branch")

1-n

U

DCID 12117 “Vessel Branch Modifiers”

4

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

M

$Measurement = DCID 12119 “Vascular Ultrasound Property”

$Derivation = DCID 3627 “Measurement Type”

5

>>

HAS CONCEPT MOD

CODE

EV (R-4089A, SRT, "Cardiac Cycle Point")

1

U

DCID 12233 “Cardiac Phase”

6

>>

HAS CONCEPT MOD

CODE

EV (R-41FFC, SRT, "Temporal period related to eating")

1

U

DT (G-A491, SRT, "Post-prandial")

7

>>

HAS CONCEPT MOD

CODE

EV (125105, DCM, "Measurement Orientation")

1

U

DCID 12118 “Measurement Orientation”

8

>>

HAS PROPERTIES

NUM

EV (125106, DCM, "Doppler Angle")

1

U

UNIT = EV (deg, UCUM, "degrees")

9

>>

HAS PROPERTIES

NUM

EV (125107, DCM, "Sample Volume Depth")

1

U

UNIT = EV (cm, UCUM, "cm")


Content Item Descriptions

Row 1

Specifies the anatomic context of the observations in the group.

Row 2

Details the anatomical location, e.g., proximal, middle, or distal

Row 3

The particular vessel branch, such as the inferior, medial or lateral

Row 5

Cardiac phase (systolic, diastolic), especially for aorta measurements

Row 6

Eating phase, especially for mesenteric and celiac measurements

TID 5105 Ultrasound Graft Section

This template is a container of measurements on a vascular graft.

Type:

Extensible

Order:

Significant

Table TID 5105. Ultrasound Graft Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

DT (121070, DCM, "Findings")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (G-C0E3, SRT, "Finding Site")

1

M

DT (T-D000F, SRT, "Vascular Graft")

3

>

HAS CONCEPT MOD

CODE

EV (G-C171, SRT, "Laterality")

1

U

DCID 244 “Laterality”

4

>

HAS CONCEPT MOD

CODE

DT (G-D871, SRT, "Proximal anastomosis")

1

M

BCID 12103 “Vascular Ultrasound Anatomic Location”

5

>

HAS CONCEPT MOD

CODE

DT (G-D872, SRT, "Distal Anastomosis")

1

M

BCID 12103 “Vascular Ultrasound Anatomic Location”

6

>

HAS CONCEPT MOD

CODE

DT (125102, DCM, "Graft Type")

1

U

No BCID

7

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

M

$Measurement = DCID 12119 “Vascular Ultrasound Property”


Content Item Descriptions

Proximal anastomosis

The proximal location of the graft

Distal anastomosis

The distal location of the graft

Graft type

The type of graft, e.g., "in situ", "prosthetic", "autogenous"