This Context Group comprises the ECG lead identifiers of ISO/IEEE 11073-10101, including human and canine leads. The terms included in the table below may not constitute the complete list; see the ISO/IEEE Standard.
Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10101 available through http://standards.ieee.org.
Extensible
20130613
Table CID 3001. ECG Leads
Coding Scheme |
Code Value |
Code Meaning |
ISO/IEEE 11073 MDC Equivalent Reference ID (Informative) |
---|---|---|---|
MDC |
2:71 |
Lead A (Nehb - Anterior) |
MDC_ECG_LEAD_A |
MDC |
2:75 |
Auxiliary unipolar lead 1 |
MDC_ECG_LEAD_A1 |
MDC |
2:76 |
Auxiliary unipolar lead 2 |
MDC_ECG_LEAD_A2 |
MDC |
2:77 |
Auxiliary unipolar lead 3 |
MDC_ECG_LEAD_A3 |
MDC |
2:78 |
Auxiliary unipolar lead 4 |
MDC_ECG_LEAD_A4 |
MDC |
2:127 |
Auxiliary bipolar lead 1 |
MDC_ECG_LEAD_AB1 |
MDC |
2:128 |
Auxiliary bipolar lead 2 |
MDC_ECG_LEAD_AB2 |
MDC |
2:129 |
Auxiliary bipolar lead 3 |
MDC_ECG_LEAD_AB3 |
MDC |
2:130 |
Auxiliary bipolar lead 4 |
MDC_ECG_LEAD_AB4 |
MDC |
2:133 |
EASI Lead AI |
MDC_ECG_LEAD_AI |
MDC |
2:132 |
EASI Lead AS |
MDC_ECG_LEAD_AS |
MDC |
2:64 |
aVF, augmented voltage, foot |
MDC_ECG_LEAD_AVF |
MDC |
2:63 |
aVL, augmented voltage, left |
MDC_ECG_LEAD_AVL |
MDC |
2:62 |
aVR, augmented voltage, right |
MDC_ECG_LEAD_AVR |
MDC |
2:65 |
−aVR |
MDC_ECG_LEAD_AVRneg |
MDC |
2:86 |
Chest lead |
MDC_ECG_LEAD_C |
MDC |
2:124 |
negative: low right scapula Lead |
MDC_ECG_LEAD_CB5 |
MDC |
2:98 |
Chest lead (symmetric placement) |
MDC_ECG_LEAD_CC |
MDC |
2:99 |
Chest lead per V1 and V1R placement |
MDC_ECG_LEAD_CC1 |
MDC |
2:100 |
Chest lead per V2 and V2R placement |
MDC_ECG_LEAD_CC2 |
MDC |
2:101 |
Chest lead per V3 and V3R placement |
MDC_ECG_LEAD_CC3 |
MDC |
2:102 |
Chest lead per V4 and V4R placement |
MDC_ECG_LEAD_CC4 |
MDC |
2:19 |
Chest lead per V5 and V5R placement |
MDC_ECG_LEAD_CC5 |
MDC |
2:103 |
Chest lead per V6 and V6R placement |
MDC_ECG_LEAD_CC6 |
MDC |
2:104 |
Chest lead per V7 and V8R placement |
MDC_ECG_LEAD_CC7 |
MDC |
2:122 |
Lead CH5 |
MDC_ECG_LEAD_CH5 |
MDC |
2:105 |
Chest-manubrium lead |
MDC_ECG_LEAD_CM |
MDC |
2:106 |
Chest-manubrium lead per V1 placement |
MDC_ECG_LEAD_CM1 |
MDC |
2:107 |
Chest-manubrium lead per V2 placement |
MDC_ECG_LEAD_CM2 |
MDC |
2:108 |
Chest-manubrium lead per V3 placement |
MDC_ECG_LEAD_CM3 |
MDC |
2:109 |
Chest-manubrium lead per V4 placement |
MDC_ECG_LEAD_CM4 |
MDC |
2:20 |
Chest-manubrium lead per V5 placement |
MDC_ECG_LEAD_CM5 |
MDC |
2:110 |
Chest-manubrium lead per V6 placement |
MDC_ECG_LEAD_CM6 |
MDC |
2:121 |
Chest-manubrium lead per V7 placement |
MDC_ECG_LEAD_CM7 |
MDC |
2:125 |
Lead CR5 |
MDC_ECG_LEAD_CR5 |
MDC |
2:123 |
negative: right infraclavicular fossa |
MDC_ECG_LEAD_CS5 |
MDC |
2:148 |
Canine, fifth right intercostal space near edge of sternum |
MDC_ECG_LEAD_CV5RL |
MDC |
2:149 |
Canine, sixth left intercostal space near edge of sternum |
MDC_ECG_LEAD_CV6LL |
MDC |
2:150 |
Canine, sixth left intercostal space at costochondral junction |
MDC_ECG_LEAD_CV6LU |
MDC |
2:70 |
Lead D (Nehb - Dorsal) |
MDC_ECG_LEAD_D |
MDC |
2:114 |
Derived Lead aVF |
MDC_ECG_LEAD_dAVF |
MDC |
2:113 |
Derived Lead aVL |
MDC_ECG_LEAD_dAVL |
MDC |
2:112 |
Derived Lead aVR |
MDC_ECG_LEAD_dAVR |
MDC |
2:73 |
Defibrillator lead: anterior-lateral |
MDC_ECG_LEAD_DEFIB |
MDC |
2:31 |
Derived Lead I |
MDC_ECG_LEAD_dI |
MDC |
2:32 |
Derived Lead II |
MDC_ECG_LEAD_dII |
MDC |
2:111 |
Derived Lead III |
MDC_ECG_LEAD_dIII |
MDC |
2:33 |
Derived Lead V1 |
MDC_ECG_LEAD_dV1 |
MDC |
2:34 |
Derived Lead V2 |
MDC_ECG_LEAD_dV2 |
MDC |
2:35 |
Derived Lead V3 |
MDC_ECG_LEAD_dV3 |
MDC |
2:36 |
Derived Lead V4 |
MDC_ECG_LEAD_dV4 |
MDC |
2:37 |
Derived Lead V5 |
MDC_ECG_LEAD_dV5 |
MDC |
2:38 |
Derived Lead V6 |
MDC_ECG_LEAD_dV6 |
MDC |
2:131 |
EASI Lead ES |
MDC_ECG_LEAD_ES |
MDC |
2:74 |
External pacing lead: anterior-posterior |
MDC_ECG_LEAD_EXTERN |
MDC |
2:27 |
Frank Lead A |
MDC_ECG_LEAD_fA |
MDC |
2:26 |
Frank Lead C |
MDC_ECG_LEAD_fC |
MDC |
2:25 |
Frank Lead E |
MDC_ECG_LEAD_fE |
MDC |
2:29 |
Frank Lead F |
MDC_ECG_LEAD_fF |
MDC |
2:30 |
Frank Lead H |
MDC_ECG_LEAD_fH |
MDC |
2:24 |
Frank Lead I |
MDC_ECG_LEAD_fI |
MDC |
2:28 |
Frank Lead M |
MDC_ECG_LEAD_fM |
MDC |
2:1 |
Lead I |
MDC_ECG_LEAD_I |
MDC |
2:2 |
Lead II |
MDC_ECG_LEAD_II |
MDC |
2:61 |
Lead III |
MDC_ECG_LEAD_III |
MDC |
2:72 |
Lead J (Nehb - Inferior) |
MDC_ECG_LEAD_J |
MDC |
2:21 |
Left Arm Lead |
MDC_ECG_LEAD_LA |
MDC |
2:23 |
Left Leg Lead |
MDC_ECG_LEAD_LL |
MDC |
2:91 |
Modified chest lead (left arm indifferent) |
MDC_ECG_LEAD_MCL |
MDC |
2:92 |
Modified chest lead per V1 placement |
MDC_ECG_LEAD_MCL1 |
MDC |
2:93 |
Modified chest lead per V2 placement |
MDC_ECG_LEAD_MCL2 |
MDC |
2:94 |
Modified chest lead per V3 placement |
MDC_ECG_LEAD_MCL3 |
MDC |
2:95 |
Modified chest lead per V4 placement |
MDC_ECG_LEAD_MCL4 |
MDC |
2:96 |
Modified chest lead per V5 placement |
MDC_ECG_LEAD_MCL5 |
MDC |
2:97 |
Modified chest lead per V6 placement |
MDC_ECG_LEAD_MCL6 |
MDC |
2:126 |
Modified limb lead |
MDC_ECG_LEAD_ML |
MDC |
2:22 |
Right Arm Lead |
MDC_ECG_LEAD_RA |
MDC |
2:147 |
Right Leg Lead |
MDC_ECG_LEAD_RL |
MDC |
2:134 |
EASI upper sternum lead |
MDC_ECG_LEAD_S |
MDC |
2:87 |
Precordial lead |
MDC_ECG_LEAD_V |
MDC |
2:3 |
Lead V1 |
MDC_ECG_LEAD_V1 |
MDC |
2:151 |
Canine, over dorsal spinous process of 7th thoracic vertebra |
MDC_ECG_LEAD_V10 |
MDC |
2:4 |
Lead V2 |
MDC_ECG_LEAD_V2 |
MDC |
2:10 |
Lead V2R |
MDC_ECG_LEAD_V2R |
MDC |
2:5 |
Lead V3 |
MDC_ECG_LEAD_V3 |
MDC |
2:11 |
Lead V3R |
MDC_ECG_LEAD_V3R |
MDC |
2:6 |
Lead V4 |
MDC_ECG_LEAD_V4 |
MDC |
2:12 |
Lead V4R |
MDC_ECG_LEAD_V4R |
MDC |
2:7 |
Lead V5 |
MDC_ECG_LEAD_V5 |
MDC |
2:13 |
Lead V5R |
MDC_ECG_LEAD_V5R |
MDC |
2:8 |
Lead V6 |
MDC_ECG_LEAD_V6 |
MDC |
2:14 |
Lead V6R |
MDC_ECG_LEAD_V6R |
MDC |
2:9 |
Lead V7 |
MDC_ECG_LEAD_V7 |
MDC |
2:15 |
Lead V7R |
MDC_ECG_LEAD_V7R |
MDC |
2:66 |
Lead V8 |
MDC_ECG_LEAD_V8 |
MDC |
2:68 |
Lead V8R |
MDC_ECG_LEAD_V8R |
MDC |
2:67 |
Lead V9 |
MDC_ECG_LEAD_V9 |
MDC |
2:69 |
Lead V9R |
MDC_ECG_LEAD_V9R |
MDC |
2:90 |
Lead VF, nonaugmented voltage, vector of LL |
MDC_ECG_LEAD_VF |
MDC |
2:89 |
Lead VL, nonaugmented voltage, vector of LA |
MDC_ECG_LEAD_VL |
MDC |
2:88 |
Lead VR, nonaugmented voltage, vector of RA |
MDC_ECG_LEAD_VR |
MDC |
2:16 |
Lead X |
MDC_ECG_LEAD_X |
MDC |
2:17 |
Lead Y |
MDC_ECG_LEAD_Y |
MDC |
2:18 |
Lead Z |
MDC_ECG_LEAD_Z |
MDC |
2:0 |
Unspecified lead |
MDC_ECG_LEAD_CONFIG |
A prior version of this context group used codes from the SCP-ECG vocabulary.
In a prior version of this table, the code 2:26 was specified for the concept Chest lead and the code 2:19 was specified for the concept Chest-manubrium lead per V5 placement.