DICOM PS3.21 2026d - Transformations between DICOM and other Representations

PS3.21

DICOM PS3.21 2026d - Transformations between DICOM and other Representations

DICOM Standards Committee

A DICOM® publication


Table of Contents

Notice and Disclaimer
Foreword
1. Scope and Field of Application
2. Normative and Informative References
Bibliography
3. Definitions
Glossary
4. Symbols and Abbreviations
5. Conventions
A. Transformation Between AIM and DICOM SR
A.1. Scope and Field of Application
A.2. Use Cases
A.3. Structure of DICOM SR Documents
A.3.1. Header
A.3.2. Document Body
A.3.2.1. DICOM SR "Measurement Report" Template Structure
A.3.2.2. Mapping Considerations
A.3.2.3. DICOM Composite Object References
A.4. Structure of AIM Version 4 Instances
A.5. AIM v4 Structure
A.6. AIM v4 to DICOM TID 1500 Mapping
A.6.1. Mapping of Constrained AIM v4
A.6.1.1. Header
A.6.1.1.1. Mapping of DICOM Patient Module
A.6.1.1.2. Mapping of DICOM Clinical Trial Subject Module
A.6.1.1.3. Mapping of DICOM General Study Module
A.6.1.1.4. Mapping of DICOM Patient Study Module
A.6.1.1.5. Mapping of DICOM Clinical Trial Study Module
A.6.1.1.6. Mapping of DICOM SR Document Series Module
A.6.1.1.7. Mapping of DICOM Clinical Trial Series Module
A.6.1.1.8. Mapping of DICOM General Equipment Module
A.6.1.1.9. Mapping of DICOM SR Document General Module
A.6.1.1.10. Mapping of DICOM SR Document Content Module
A.6.1.1.11. Mapping of DICOM SOP Common Module
A.6.1.2. Content Tree
TID 1500. Mapping of Measurement Report
TID 1501. Mapping of Measurement Group
TID 1502. Mapping of Time Point Context
TID 1410. Mapping of Planar ROI Measurements
TID 1411. Mapping of Volumetric ROI Measurements
TID 1419. Mapping of ROI Measurements
TID 1420. Mapping of Measurements Derived From Multiple ROI Measurements
TID 300. Mapping of Measurement
TID 320. Mapping of Image or Spatial Coordinates
TID 4019. Mapping of Algorithm Identification
TID 4108. Mapping of Tracking Identifier
TID 1204. Mapping of Language of Content Item and Descendants
TID 1001. Mapping of Observation Context
TID 1002. Mapping of Observer Context
TID 1003. Mapping of Person Observer Identifying Attributes
TID 1600. Mapping of Image Library
TID 1601. Mapping of Image Library Entry
TID 1602. Mapping of Image Library Entry Descriptors
A.7. Sample Documents
A.7.1. Source AIM v4 Instance
A.7.2. Target DICOM SR "Measurement Report" (TID 1500)
A.8. Overview of Data Types

List of Figures

A.2-1. Annotation Creation and Transformation
A.3-1. SR Document Structure
A.3.2.1-1. Template Structure Summarized from PS 3.16
A.4-1. AIM v4 Instance Structure

List of Tables

A.3.1-1. Transformation of DICOM SR IOD Modules
A.6.1.1.1-1. Mapping of DICOM Patient Module
A.6.1.1.3-1. Mapping of DICOM General Study Module
A.6.1.1.6-1. Mapping of DICOM SR Document Series Module
A.6.1.1.8-1. Mapping of DICOM General Equipment Module
A.6.1.1.9-1. Mapping of DICOM SR Document General Module
A.6.1.1.11-1. Mapping of DICOM SOP Common Module
TID 1500. Mapping of Measurement Report
TID 1501. Mapping of Measurement Group
TID 1502. Mapping of Time Point Context
TID 1410. Mapping of Planar ROI Measurements
TID 1411. Mapping of Volumetric ROI Measurements
TID 1419. Mapping of ROI Measurements
TID 1420. Mapping of Measurements Derived From Multiple ROI Measurements
TID 300. Mapping of Measurement
TID 320. Mapping of Image or Spatial Coordinates
TID 4019. Mapping of Algorithm Identification
TID 4108. Mapping of Tracking Identifier
TID 1204. Mapping of Language of Content Item and Descendants
TID 1001. Mapping of Observation Context
TID 1002. Mapping of Observer Context
TID 1003. Mapping of Person Observer Identifying Attributes
TID 1600. Mapping of Image Library
TID 1601. Mapping of Image Library Entry
TID 1602. Mapping of Image Library Entry Descriptors
A.7.2-1. Transformed SR document encoding at the Attribute level
A.8-1. ISO 21090 Data Types used in AIM V4
A.8-2. Mapping between DICOM Basic Code Attributes and AIM ISO 21090 Code Data Types (CD)
A.8-3. Mapping between DICOM Person Name (PN) ans ISO 21090 Data Type Person Name (PN)
A.8-4. Mapping between DICOM Numeric Measurement Value Types and ISO 21090 Data Types
A.8-5. Mapping between DICOM Numeric Value Qualifier Code Sequence and AIM ST
A.8-6. DICOM Image references to AIM Path
A.8-7. DICOM Segmentation references to AIM Path

List of Examples

A.8-1. Person Name Example
A.8-2. HL7 V3 Multi-Part Person Name Example