The origin server shall perform a search according to the requirements specified in Section 8.3.4.
For each matching modality scheduled procedure step, the origin server shall include in the results:
All Attributes in Table K.6-1 “Attributes for the Modality Worklist Information Model” in PS3.4 with a Return Key Type of 1 or 2.
All Attributes in Table K.6-1 “Attributes for the Modality Worklist Information Model” in PS3.4 with a Return Key Type of 1C or 2C for which the conditional requirements are met.
All other Attributes passed as match parameters that are supported by the origin server as either matching or return Attributes.
All other Attributes passed as includefield parameter values that are supported by the origin server as return Attributes.