Studies (see Section 10.1.1)
|
|
studies
|
Search for Studies
Store Instances
|
Section 10.6
Section 10.5
|
|
{StudyInstance}
|
Retrieve Study
Store Study Instances
|
Section 10.4
Section 10.5
|
|
metadata
|
Retrieve Study Metadata
|
Section 10.4
|
|
rendered
|
Retrieve Rendered Study
|
Section 10.4
|
|
renderedmpr
|
Retrieve Rendered MPR Volume Study
|
Section 10.4
|
|
rendered3d
|
Retrieve Rendered 3D Volume Study
|
Section 10.4
|
|
thumbnail
|
Retrieve Study Thumbnail
|
Section 10.4
|
|
bulkdata
|
Retrieve Study Bulk Data
|
Section 10.4
|
|
pixeldata
|
Retrieve Study Pixel Data
|
Section 10.4
|
|
series
|
Search for Study Series
|
Section 10.6
|
|
{SeriesInstance}
|
Retrieve Series
|
Section 10.4
|
|
metadata
|
Retrieve Series Metadata
|
Section 10.4
|
|
rendered
|
Retrieve Rendered Series
|
Section 10.4
|
|
renderedmpr
|
Retrieve Rendered MPR Volume Series
|
Section 10.4
|
|
rendered3d
|
Retrieve Rendered 3D Volume Series
|
Section 10.4
|
|
thumbnail
|
Retrieve Series Thumbnail
|
Section 10.4
|
|
bulkdata
|
Retrieve Series Bulk Data
|
Section 10.4
|
|
pixeldata
|
Retrieve Series Pixel Data
|
Section 10.4
|
|
instances
|
Search for Study Series Instances
|
Section 10.4
|
|
{SOPInstance}
|
Retrieve Instance
|
Section 10.4
|
|
metadata
|
Retrieve Instance Metadata
|
Section 10.4
|
|
rendered
|
Retrieve Rendered Instance
|
Section 10.4
|
|
renderedmpr
|
Retrieve Rendered MPR Volume Instance
|
Section 10.4
|
|
rendered3d
|
Retrieve Rendered 3D Volume Instance
|
Section 10.4
|
|
thumbnail
|
Retrieve Instance Thumbnail
|
Section 10.4
|
|
bulkdata
|
Retrieve Instance Bulk Data
|
Section 10.4
|
|
pixeldata
|
Retrieve Instance Pixel Data
|
Section 10.4
|
|
frames
|
N/A
|
N/A
|
|
{framelist}
|
Retrieve Frames
|
Section 10.4
|
|
rendered
|
Retrieve Rendered Frames
|
Section 10.4
|
|
renderedmpr
|
Retrieve Rendered MPR Volume Frames
|
Section 10.4
|
|
rendered3d
|
Retrieve Rendered 3D Volume Frames
|
Section 10.4
|
|
thumbnail
|
Retrieve Frame Thumbnail
|
Section 10.4
|
|
pixeldata
|
Retrieve Frame Pixel Data
|
Section 10.4
|
|
instances
|
Search for Study Instances
|
Section 10.6
|
|
series
|
Search for Series
|
Section 10.6
|
|
{SeriesInstance}
|
N/A
|
N/A
|
|
{instances}
|
Search for Instances
|
Section 10.6
|
|
instances
|
Search for Instances
|
Section 10.6
|
|
{BulkDataReference}
|
Retrieve Bulk Data
|
Section 10.4
|
|
Worklist (see Section 11.1.1)
|
|
workitems
|
Search for Workitem
Create Workitem
|
Section 11.9
Section 11.4
|
|
{Workitem}
|
Retrieve Workitem
Update Workitem
|
Section 11.4
Section 11.6
|
|
state
|
Change Workitem State
|
Section 11.7
|
|
cancelrequest
|
Request Workitem Cancellation
|
Section 11.8
|
|
subscribers
|
N/A
|
N/A
|
|
{AETitle}
|
Subscribe
Unsubscribe
|
Section 11.10
Section 11.11
|
|
1.2.840.10008.5.1.4.34.5
|
N/A
|
N/A
|
|
subscribers
|
N/A
|
N/A
|
|
{AETitle}
|
Subscribe
Unsubscribe
|
Section 11.10
Section 11.11
|
|
suspend
|
Unsubscribe
|
Section 11.11
|
|
1.2.840.10008.5.1.4.34.5.1
|
N/A
|
N/A
|
|
subscribers
|
N/A
|
N/A
|
|
{AETitle}
|
Subscribe
Unsubscribe
|
Section 11.10
Section 11.11
|
|
suspend
|
Suspend Worklist Subscription
|
Section 11.11
|
|
Non-Patient Instance (see Section 12.1.1)
|
|
color-palettes
|
N/A
|
N/A
|
|
{uid}
|
Retrieve
Store
Search
|
Section 12.4
Section 12.5
Section 12.6
|
|
defined-procedure-protocol
|
N/A
|
N/A
|
|
{uid}
|
Retrieve
Store
Search
|
Section 12.4
Section 12.5
Section 12.6
|
|
hanging-protocol
|
N/A
|
N/A
|
|
{uid}
|
Retrieve
Store
Search
|
Section 12.4
Section 12.5
Section 12.6
|
|
implant-templates
|
N/A
|
N/A
|
|
{uid}
|
Retrieve
Store
Search
|
Section 12.4
Section 12.5
Section 12.6
|
|
inventories
|
N/A
|
N/A
|
|
{uid}
|
Retrieve
Store
Search
|
Section 12.4
Section 12.5
Section 12.6
|
|
Storage Commitment requests (see Section 13.1.1)
|
|
commitment-requests
|
Request
|
Section 13.4
|
|
Result Check
|
Section 13.5
|
|
Modality Scheduled Procedure Step Service (see Section 14.1.1)
|
|
modality-scheduled-procedure-steps
|
Search
|
Section 14.4
|
|
Modality Performed Procedure Step Service (see Section 15.1.1)
|
|
modality-performed-procedure-steps
|
Create
|
Section 15.4
|
|
Update
|
Section 15.5
|
|
Retrieve
|
Section 15.6
|