DICOM PS3.16 2026c - Content Mapping Resource

TID 9003 Previous Procedure

This general Template provides detailed information on a patient's previous procedure, surgery, or treatment.

Table TID 9003. Parameters

Parameter Name

Parameter Usage

$ProcedureList

Coded term or Context Group for value of Previous Procedure

$ProcedureModifier

Coded term or Context Group for value of Previous Procedure Modifier

$NumConceptName

Coded term or Context Group for the concept name of a numeric property of the Previous Procedure

$LateralityValue

Coded term or Context Group for value of Laterality

$ProcedureResult

Coded term or Context Group for value of Result of Procedure

$ComplicationValue

Coded term or Context Group for value of Complication


Type:

Extensible

Order:

Significant

Root:

No

Table TID 9003. Previous Procedure

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111513, DCM, "Relevant Previous Procedures")

1

M

2

>

CONTAINS

CODE

EV (111531, DCM, "Previous Procedure")

1-n

M

$ProcedureList

3

>>

HAS CONCEPT MOD

CODE

EV (111464, DCM, "Procedure Modifier")

1-n

U

$ProcedureModifier

4

>>

HAS OBS CONTEXT

CODE

EV (111534, DCM, "Role of person reporting")

1

U

DCID 7450 “Person Role”

5

>>

HAS PROPERTIES

NUM

$NumConceptName

1-n

U

6

>>

HAS PROPERTIES

CODE

EV (272741003, SCT, "Laterality")

1

U

$LateralityValue

7

>>

HAS PROPERTIES

DATETIME

EV (122146, DCM, "Procedure DateTime")

1

UC

XOR Row 8

8

>>

HAS PROPERTIES

CODE

EV (111395, DCM, "Estimated Timeframe")

1

UC

XOR Row 7

BCID 6164 “Time Interval”

9

>>

HAS PROPERTIES

NUM

EV (246432004, SCT, "Number of occurrences")

1

U

UNITS = EV (1, UCUM, "no units")

10

>>

HAS PROPERTIES

CODE

EV (116224001, SCT, "Complication of procedure")

1-n

U

$ComplicationValue

11

>>>

HAS PROPERTIES

CODE

EV (111466, DCM, "Severity of Complication")

1

U

DCID 251 “Complication Severity”

12

>>

HAS PROPERTIES

CODE

EV (122177, DCM, "Procedure Result")

1

U

$ProcedureResult

13

>>

HAS PROPERTIES

INCLUDE

DTID 4207 “Breast Imaging Pathology Results”

1-n

U


DICOM PS3.16 2026c - Content Mapping Resource