DICOM PS3.16 2026b - Content Mapping Resource

TID 9002 Medication, Substance, Environmental Exposure

This general Template provides detailed information on a patient's medication or substance use, or exposure to environmental factors, including type and duration of use or exposure.

Table TID 9002. Parameters

Parameter Name

Parameter Usage

$ContainerConcept

Coded term for the concept name of the CONTAINER, identifying it as medication, substance, or environmental exposure history.

$CodeConcept

Coded term for the concept name of the CODE, identifying it as medication, substance, or environmental exposure.

$CodeValue

Coded term or Context Group for value of the medication, substance, or environmental exposure.

$Classification

Coded term or Context Group for classification of the medication, substance, or environmental exposure.

$Route

Coded term or Context Group for the route of administration of the medication, substance, or route of environmental exposure.

$Site

Coded term or Context Group for the anatomical site of administration of the medication, substance, or anatomical site of environmental exposure.


Type:

Extensible

Order:

Significant

Root:

No

Table TID 9002. Medication, Substance, Environmental Exposure

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

$ContainerConcept

1

M

2

>

CONTAINS

CODE

$CodeConcept

1-n

M

$CodeValue

3

>>

HAS CONCEPT MOD

CODE

EV (278201002, SCT, "Classification")

1

U

$Classification

4

>>

HAS OBS CONTEXT

CODE

EV (111534, DCM, "Role of person reporting")

1

U

DCID 7450 “Person Role”

5

>>

HAS PROPERTIES

NUM

EV (111524, DCM, "Age Started")

1

U

DCID 7456 “Age Unit”

6

>>

HAS PROPERTIES

NUM

EV (111525, DCM, "Age Ended")

1

U

DCID 7456 “Age Unit”

7

>>

HAS PROPERTIES

DATETIME

EV (111526, DCM, "DateTime Started")

1

U

8

>>

HAS PROPERTIES

DATETIME

EV (111527, DCM, "DateTime Ended")

1

U

9

>>

HAS PROPERTIES

NUM

EV (103335007, SCT, "Duration")

1

U

UNITS = DCID 6046 “Follow-up Interval Unit”

10

>>

HAS PROPERTIES

CODE

EV (111528, DCM, "Ongoing")

1

U

DCID 230 “Yes-No”

11

>>

HAS PROPERTIES

TEXT

EV (111529, DCM, "Brand Name")

1

U

12

>>

HAS PROPERTIES

NUM

DCID 6092 “Usage/Exposure Qualitative Concept”

1

U

The unit of measure shall be quantity per unit of time

13

>>

HAS PROPERTIES

CODE

DCID 6093 “Usage/Exposure/Amount Qualitative Concept”

1

U

DCID 6090 “Relative Usage/Exposure Amount”

14

>>

HAS PROPERTIES

CODE

DCID 6094 “Usage/Exposure/Frequency Qualitative Concept”

1

U

DCID 6091 “Relative Frequency of Event Value”

15

>>

HAS PROPERTIES

CODE

EV (410675002, SCT, "Route of administration")

1

U

$Route

16

>>>

HAS PROPERTIES

CODE

EV (272737002, SCT, "Site of")

1

U

$Site

17

>>>>

HAS CONCEPT MOD

CODE

EV (272741003, SCT, "Laterality")

1

MC

IF Row 16 has laterality

DCID 244 “Laterality”


Content Item Descriptions

Row 3

Classification is mapped in UMLS to (C0008902, UMLS, "Classification"). Its definition is completely generic; i.e., it does not refer to any particular type of classification.

Rows 13 & 14

If both of these Content Items are instantiated, the concept names selected for each should match. For example, use "Relative dose amount" as the concept name for Row 13 with "Relative dose frequency" as the concept name for Row 14.

Row 15

Even though the concept name is route of administration, it is also used for route of exposure in the case of environmental exposure.

Rows 16, 17

This pattern of route with a site and laterality modifier follows that used in TID 10022 “Radiopharmaceutical Administration Event Data”.

DICOM PS3.16 2026b - Content Mapping Resource