DICOM PS3.16 2026b - Content Mapping Resource

TID 8131 Medications and Mixture Medications

This template encodes a description of medications (including but not limited to anesthetic agents) used during a procedure (e.g., pre-medication drugs for an imaging procedure on humans, or anesthesia for imaging of research small animals).

Note

This template combines selected concepts from the [AQI Schema] elements, their complex types, and their children:

Table TID 8131. Parameters

Parameter Name

Parameter Usage

$DrugAdministered

Type of drug administered


Type:

Extensible

Order:

Non-Significant

Root:

No

Table TID 8131. Medications and Mixture Medications

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (182833002, SCT, "Medication given")

1

M

2

>

CONTAINS

DATETIME

EV (111526, DCM, "DateTime Started")

1

U

3

>

CONTAINS

DATETIME

EV (111527, DCM, "DateTime Ended")

1

U

4

>

CONTAINS

CODE

EV (410675002, SCT, "Route of administration")

1

M

DCID 11 “Administration Route”

5

>

CONTAINS

CONTAINER

EV (272163001, SCT, "Mixture")

1-n

M

6

>>

CONTAINS

CODE

EV (122083, DCM, "Drug administered")

1

MC

XOR Row 7

$DrugAdministered

7

>>

CONTAINS

TEXT

EV (122083, DCM, "Drug administered")

1

MC

XOR Row 6

8

>>

CONTAINS

CODE

EV (111516, DCM, "Medication Type")

1

M

DCID 621 “Medication Type for Small Animal Anesthesia”

DCID 76 “Premedication Type”

9

>>

CONTAINS

NUM

EV (260911001, SCT, "Dosage")

1

U

UNITS = DCID 82 “Measurement Unit”

10

>>

CONTAINS

NUM

EV (122093, DCM, "Concentration")

1

U

UNITS = DCID 82 “Measurement Unit”

11

>>

CONTAINS

CODE

EV (113510, DCM, "Drug Product Identifier")

1

U

12

>>>

HAS PROPERTIES

TEXT

EV (111529, DCM, "Brand Name")

1

U

13

>>

CONTAINS

NUM

DCID 3410 “Drug/Contrast Numeric Parameter”

1-n

U


Content Item Descriptions

Row 1

AQI Medication type and element correspond to (182833002, SCT, "Medication given") (situation). (See TID 3806 Cath Procedure).

Rows 2, 3

AQI DoseStart and DoseEnd elements correspond to (111526, DCM, "DateTime Started") and (111527, DCM, "DateTime Ended") respectively. If the medication is delivered as a bolus, the end time is omitted.

Row 4

AQI MedicationRoute corresponds to (410675002, SCT, "Route of administration"). The existing CID 11 “Administration Route” contains a relevant subset of concepts for the enumerated values of AQI MedicationRouteCodeType.

Row 5

The AQI schema allows the Medication type not only to describe medications with a single component, but also to add MixtureMedications children, each of which is encoded following a similar pattern to the contents of Medication, though the start and end time and route of administration are shared. This had been modeled by allowing every medication to have one or more mixture children. For medications that are not a mixture, a single instance of this row defines the medication (even though the mixture container is still used).

Rows 6, 7

AQI MedicationName and MixtureMedicationName elements correspond to (122083, DCM, "Drug administered"). (See TID 3806 Cath Procedure). The medication (e.g., anesthesia agent) can be described with a code or text, e.g., (387368002, SCT, "Isoflurane") or "isoflurane".

Row 9

Both AQI MedDose (or MixtureMedDose) and DoseUnits (or MixtureDoseUnits) elements are combined in one Content Item. Units are required to be encoded as UCUM but are not otherwise constrained.

Row 10

Both AQI MedConcentration (or MixtureMedConcentration) and MedConcentrationUnit (or MixtureMedConcentrationUnit) elements are combined in one Content Item. Units are required to be encoded as UCUM but are not otherwise constrained.

Row 11

Registered drug establishment code for the product. Equivalent codes can be encoded in this item using the Equivalent Code Sequence (0008,0121). See Section 8.9 “Equivalent Code Sequence” in PS3.3 .

DICOM PS3.16 2026b - Content Mapping Resource