DICOM PS3.16 2026b - Content Mapping Resource

TID 8130 Anesthesia

This template encodes a description of the anesthesia applied during a procedure (e.g., imaging of research small animals).

Note

This template combines selected concepts from the [AQI Schema] elements, their complex types, and their children:

Type:

Extensible

Order:

Non-Significant

Root:

No

Table TID 8130. Anesthesia

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (399097000, SCT, "Administration of anesthesia")

1

M

2

>

CONTAINS

CONTAINER

EV (127300, DCM, "Anesthesia Method Set")

1

M

3

>>

CONTAINS

CONTAINER

EV (127301, DCM, "Anesthesia Method")

1-n

M

4

>>>

CONTAINS

CODE

EV (127302, DCM, "Anesthesia Category")

1

M

DCID 611 “Anesthesia Category Code Type for Small Animal Anesthesia”

5

>>>

CONTAINS

TEXT

EV (127303, DCM, "Anesthesia SubCategory")

1

U

6

>>>

CONTAINS

DATETIME

EV (398325003, SCT, "Anesthesia Start Time")

1

U

7

>>>

CONTAINS

DATETIME

EV (398164008, SCT, "Anesthesia Finish Time")

1

U

8

>>>

CONTAINS

CODE

EV (241687005, SCT, "Anesthesia Induction")

1

U

DCID 613 “Anesthesia Induction Code Type for Small Animal Anesthesia”

9

>>>

CONTAINS

CODE

EV (241695009, SCT, "Anesthesia Maintenance")

1

U

DCID 615 “Anesthesia Maintenance Code Type for Small Animal Anesthesia”

10

>>>

CONTAINS

TEXT

EV (121106, DCM, "Comment")

1

U

11

>

CONTAINS

CONTAINER

EV (127310, DCM, "Airway Management Set")

1

M

12

>>

CONTAINS

CONTAINER

EV (386509000, SCT, "Airway Management")

1-n

M

13

>>>

CONTAINS

CODE

EV (127312, DCM, "Airway Management Method")

1

M

DCID 617 “Airway Management Method Code Type for Small Animal Anesthesia”

14

>>>

CONTAINS

CODE

EV (127313, DCM, "Airway Sub-Management Method")

1

M

DCID 619 “Airway Management Sub-Method Code Type for Small Animal Anesthesia”

15

>

CONTAINS

CONTAINER

EV (127320, DCM, "Medications Set")

1-n

M

16

>>

CONTAINS

CODE

EV (128954007, SCT, "Procedure Phase")

1

M

DCID 631 “Procedure Phase Requiring Anesthesia”

17

>>

CONTAINS

INCLUDE

DTID 8131 “Medications and Mixture Medications”

1-n

M

$DrugAdministered = DCID 623 “Medication for Small Animal Anesthesia”


Content Item Descriptions

Rows 1, 2, 3

If this template is used, at least one description of anesthesia method is required. Note that the specific agents used are described separately, as intra-operative medications, per the [AQI Schema].

Rows 6, 7

These correspond to AQI elements that are named "Time" rather than "DateTime", though their value is a DateTime; the DICOM naming convention is used here.

Row 9

Only inhalational methods of maintenance are included in this row. Absence of this row implies that the (non-inhalational) induction method is used for maintenance.

Row 10

The comment corresponds to AQI element "Anesthesia Notes".

Rows 11, 12, 13

At least one description of airway management is required.

The airway management method also serves as the description of the method of inhalational anesthesia delivery, even if it does not involve "management" of the "airway" per se (e.g., delivery via nose cone).

Rows 15, 16, 17

In the AQI model, a single AQI MedicationsSet is used in the AQI IntraOp element to describe intra-operative medications.

This template allows a more general usage, with one or more Medications Set containers, each of which may be qualified by the phase of the procedure (pre-operative, intra-operative or post-operative). The purpose of the medication (e.g., general anesthetic) is described in the (111516, DCM, "Medication Type") of the included TID 8131 “Medications and Mixture Medications”.

DICOM PS3.16 2026b - Content Mapping Resource