DICOM PS3.16 2026c - Content Mapping Resource

TID 3814 Left Ventriculography Findings

The information contained here about the left ventricle is relatively qualitative in nature. It is a high-level summary of the more detailed information that may be contained in an optional Quantitative Ventricular Analysis report. This Template addresses findings about any ventricular septal defect (Row 7), the myocardial wall (Row 11), and about the aortic root (Row 16).

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3814. Left Ventriculography Findings

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (59776-5, LN, "Findings")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (121058, DCM, "Procedure reported")

1

M

DT (265484009, SCT, "Left Ventriculography")

3

>

CONTAINS

CODE

EV (366188009, SCT, "Left Ventricular Function - Finding")

1

M

DCID 242 “Normal-Abnormal”

4

>

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (10230-1, LN, "LV Ejection Fraction")

$Units = EV (%, UCUM, "%")

$Method = DCID 3748 “Angiographic EF Testing Method”

$Derivation = DCID 3745 “Calculation Method”

5

>

CONTAINS

CODE

EV (250929008, SCT, "Left Ventricular Cavity Size")

1

U

DCID 3705 “Chamber Size”

6

>

CONTAINS

CODE

EV (250909007, SCT, "Left Ventricular Contractility")

1

U

DCID 3706 “Overall Contractility”

7

>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1

U

EV (30288003, SCT, "Ventricular Septal Defect")

8

>>

HAS PROPERTIES

CODE

EV (116676008, SCT, "Associated Morphology")

1

U

DCID 3707 “VSD Description”

9

>

CONTAINS

INCLUDE

DTID 3816 “Ventricular Assessment”

1

U

10

>

CONTAINS

CONTAINER

EV (59776-5, LN, "Findings")

1

U

11

>>

HAS CONCEPT MOD

CODE

EV (363698007, SCT, "Finding Site")

1

M

DT (272657006, SCT, "Myocardial Wall")

12

>>

CONTAINS

CODE

EV (18179-2, LN, "Wall Segment")

1-n

M

BCID 3717 “Left Ventricle Myocardial Wall 17 Segment Model”

13

>>>

HAS PROPERTIES

CODE

EV (60797005, SCT, "Cardiac Wall Motion")

1

M

DCID 3703 “Wall Motion”

14

>>>

HAS PROPERTIES

CODE

EV (116676008, SCT, "Associated Morphology")

1

U

DCID 3704 “Myocardium Wall Morphology Finding”

15

>>>

HAS PROPERTIES

NUM

DT (246262008, SCT, "Score")

1

U

16

>

CONTAINS

CONTAINER

EV (59776-5, LN, "Findings")

1

U

17

>>

HAS CONCEPT MOD

CODE

EV (363698007, SCT, "Finding Site")

1

M

DT (364091008, SCT, "Aortic Root")

18

>>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1-n

M

DCID 3709 “Aortic Root Description”


DICOM PS3.16 2026c - Content Mapping Resource