DICOM PS3.16 2026c - Content Mapping Resource

TID 3602 Cardiovascular Patient Characteristics

This Template describes the characteristics of the patient that are specific to the current clinical presentation (visit). Patient Characteristic concepts in this Template, which may replicate Attributes in the Patient Study Module, are included here as possible targets of by-reference relationships from other Content Items in the SR tree.

Note

Several of the concepts in this Template duplicate concepts in TID 1007 “Subject Context, Patient”. The difference in use is that this Template has those concepts as primary observations of the patient, while in TID 1007 “Subject Context, Patient” the concepts are used to set (or reset) the context for other observations.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3602. Cardiovascular Patient Characteristics

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (121118, DCM, "Patient Characteristics")

1

M

2

>

CONTAINS

NUM

EV (121033, DCM, "Subject Age")

1

M

UNITS = DCID 7456 “Age Unit”

3

>

CONTAINS

CODE

EV (121032, DCM, "Subject Sex")

1

M

DCID 7455 “Sex”

4

>

CONTAINS

NUM

EV (8302-2, LN, "Patient Height")

1

M

UNITS = EV (cm, UCUM, "cm")

5

>

CONTAINS

NUM

EV (29463-7, LN, "Patient Weight")

1

M

UNITS = EV (kg, UCUM, "kg")

6

>

CONTAINS

NUM

EV (122221, DCM, "Thorax diameter, sagittal")

1

U

UNITS = EV (cm, UCUM, "cm")

7

>

CONTAINS

NUM

EV (8277-6, LN, "Body Surface Area")

1

MC

IF BSA used for indexed measurements in SOP Instance

UNITS = EV (m2, UCUM, "m2")

8

>>

INFERRED FROM

CODE

EV (8278-4, LN, "Body Surface Area Formula")

1

U

BCID 3663 “Body Surface Area Equation”

9

>

CONTAINS

NUM

EV (60621009, SCT, "Body Mass Index")

1

U

UNITS = EV (kg/m2, UCUM, "kg/m2")

10

>>

INFERRED FROM

CODE

EV (121420, DCM, "Equation")

1

U

DT (122265, DCM, "BMI = Wt/Ht^2")

11

>

CONTAINS

NUM

EV (8867-4, LN, "Heart Rate")

1

U

UNITS = EV ({H.B.}/min, UCUM, "BPM")

12

>

CONTAINS

NUM

EV (271649006, SCT, "Systolic Blood Pressure")

1

U

UNITS = DCID 3500 “Pressure Unit”

13

>

CONTAINS

NUM

EV (271650006, SCT, "Diastolic Blood Pressure")

1

U

UNITS = DCID 3500 “Pressure Unit”

14

>

CONTAINS

CODE

DT (8884-9, LN, "Cardiac Rhythm")

1

U

BCID 3415 “Cardiac Rhythm”

15

>

CONTAINS

NUM

EV (248366000, SCT, "Chest Circumference")

1

U

UNITS = EV (cm, UCUM, "cm")

16

>

CONTAINS

TEXT

EV (248808008, SCT, "Breast size")

1

U

Bra size as text string

17

>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1

U

DCID 3202 “Chest Pain”

18

>

CONTAINS

CODE

EV (429160000, SCT, "Functional capacity")

1

U

DCID 3719 “Canadian Clinical Classification”

19

>

CONTAINS

CODE

EV (429160000, SCT, "Functional capacity")

1

U

DCID 3736 “NYHA Classification”

20

>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1-n

U

21

>

CONTAINS

TEXT

EV (55108-5, LN, "Patient Presentation")

1

U


Content Item Descriptions

Rows 11, 12, 13

Cardiac vital signs, for use when the SR SOP Instance does not record vital signs at multiple procedure phases or stages.

Row 16

Breast size for interpretation of attenuation in nuclear medicine imaging

DICOM PS3.16 2026c - Content Mapping Resource