TID 2005 Transcribed Diagnostic Imaging Report

Basic report Template for general diagnostic imaging interpretation reports produced in a dictation/transcription workflow. SR documents encoded using this Template are intended to be transformable to HL7 Clinical Document Architecture format (see Section X.3 “Transcribed Diagnostic Imaging CDA Instance Content” in PS3.17 and Annexes in PS3.20).

This Template can be instantiated only at the root node, and cannot be included in other Templates.

Observation Context shall be inherited from outside the Structured Report Content Tree, and shall not be changed within the Content Tree. To satisfy the requirement that Observer Context is inherited, either or both the Author Observer Sequence (0040,A078) or the Verifying Observer Sequence (0040,A073) from the SR Document General Module must be present in the SOP Instance.

Note

See Section C.17.5 “Observation Context Encoding” in PS3.3 .

Type:

Non-Extensible

Order:

Significant

Root:

Yes

Table TID 2005. Transcribed Diagnostic Imaging Report

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

BCID 7000 “Diagnostic Imaging Report Document Title”

1

M

2

>

HAS CONCEPT MOD

CODE

EV (121058, DCM, "Procedure reported")

1-n

U

3

>

HAS CONCEPT MOD

CODE

EV (122142, DCM, "Acquisition Device Type")

1-n

U

DCID 29 “Acquisition Modality”

4

>

HAS CONCEPT MOD

CODE

EV (123014, DCM, "Target Region")

1-n

U

5

>

HAS CONCEPT MOD

CODE

EV (121049, DCM, "Language of Content Item and Descendants")

1

M

DCID 5000 “Language”

6

>

CONTAINS

CONTAINER

BCID 7001 “Diagnostic Imaging Report Heading”

1-n

M

7

>>

CONTAINS

TEXT

BCID 7002 “Diagnostic Imaging Report Element”

1

U

8

>

CONTAINS

CONTAINER

EV (55113-5, LN, "Key Images")

1-n

U

9

>>

CONTAINS

TEXT

EV (113012, DCM, "Key Object Description")

1

U

10

>>

CONTAINS

IMAGE

1-n

M


Content Item Descriptions

Rows 2, 3, 4

The content of Rows 2, 3, and 4 shall not be inconsistent with the meaning of the report title of Row 1. If the report title does not include the concepts of the procedure type, modality, or target site (e.g., the generic "Diagnostic Imaging Report"), these rows may provide post-coordination of those concepts. If the report title does include such concepts (e.g., "CT Head Report"), they may be encoded duplicatively to support report categorization and search.

Row 6

CONTAINER Concept Name may be absent.

Row 10

IMAGE Concept Name shall be absent. Purpose of reference is not specified.