| DICOM PS3.16 2026b - Content Mapping Resource |
|---|
The templates that comprise the Planned Imaging Agent Administration are interconnected as in Figure A-19.
This template describes single administration plan.
This template defines a container (the root) with subsidiary Content Items, each of which corresponds to a single Imaging Agent Administration that is planned.
If a planned SR is a modification of a previous planned SR, it can reference the previous plan using the Predecessor Documents Sequence (0040,A360).
Table TID 11001. Planned Imaging Agent Administration
This template describes an Imaging Agent which may be a single component or a mix of multiple components used in a single administration.
Table TID 11002. Imaging Agent Information
|
IFF root Concept Name Code Sequence (130226, DCM, "Planned Imaging Agent Administration") |
This template describes a single activity as part of the single imaging administration phase. A phase activity is the lowest level of the Imaging Agent delivery model.
Table TID 11003. Imaging Agent Administration Activity
This template describes the Imaging Agent component. The brand and packaging information can be referenced under Section TID 11005 Imaging Agent Administration Consumable.
Table TID 11004. Imaging Agent Component
|
DCID 68 “Imaging Agent Administration Pharmaceutical Presentation Unit” |
||||||||
|
EV (130221, DCM, "Imaging Agent Volume Per Unit of Presentation") |
||||||||
|
IFF root Concept Name Code Sequence = (130226, DCM, "Planned Imaging Agent Administration") |
||||||||
|
IFF root Concept Name Code Sequence = (130227, DCM, "Performed Imaging Agent Administration") |
||||||||
This template describes a material or supply used in the course of an Imaging Agent administration procedure, other than the Imaging Agents themselves and the unit of presentation of the Imaging Agents if pre-filled. This includes such supplies as needles, tubing, cannulas, catheters, empty syringes. This template may describe reusable or disposable materials.
For the planned administration, these are the expected consumables. For the performed administration, this template describes what was actually used.
Table TID 11005. Imaging Agent Administration Consumable
|
EV (130223, DCM, "Imaging Agent Administration Consumable Type") |
||||||||
|
IF value of Row 2 = (19923001, SCT, "Catheter") |
||||||||
|
IF value of Row 2 = (19923001, SCT, "Catheter") If Row 10 = (82449006, SCT, "Peripheral intravenous catheter") |
UNITS = DCID 3510 “Catheter Size Unit” |
|||||||
|
IF value of Row 2 = (19923001, SCT, "Catheter") |
DCID 74 “Imaging Agent Administration Consumable Catheter Type” |
|||||||
|
IFF root Concept Name Code Sequence = (130226, DCM, "Planned Imaging Agent Administration") |
||||||||
|
IFF root Concept Name Code Sequence = (130227, DCM, "Performed Imaging Agent Administration") |
||||||||
|
Quantity of the Imaging Agent consumed or quantity of accessories or other consumables used. |
|
|
When included in TID 11020 “Performed Imaging Agent Administration”, this value indicates whether the consumable was changed (i.e., newly installed) during preparation for this administration. When included in TID 11001 “Planned Imaging Agent Administration”, this value indicates whether the consumable must be changed during preparation for this administration or whether it need not be. |
|
|
The billing codes for material used for Imaging Agent administration procedure. It does not include performance and interpretation of the imaging. |
|
|
The number from the barcode associated with the unit of presentation e.g., the individual blister package. Some examples for type of codes are UPC, EAN, GTIN. Multiple items are permitted for planned Imaging Agent administration since multiple container sizes may be allowed. |
This template provides detailed information on Imaging Agent Administration Steps. It consists of multiple administration steps; a step in turn consists of multiple administration phases.
Table TID 11006. Imaging Agent Administration Steps
This template provides detailed information on an Imaging Agent Administration step. A step is part of a plan. Steps are usually distinguished from other steps because an operator's intervention is required between steps. Steps are also distinguished when they have different routes of administration. A step may consist of multiple phases.
Table TID 11007. Imaging Agent Administration Step
This template provides detailed information on Imaging Agent Administration Phase. A phase is part of the administration step and is not interrupted except under abnormal conditions.
Table TID 11008. Imaging Agent Administration Phase
|
Imaging Agent Administration Phase Identifier is specified as numeric text string, and shall be treated as the ordinal of the recorded administration phase within an administration step (i.e., "1" for the first phase, "2" for the second, etc.). |
|
|
Indicates any occurrence of a manual suspend/resume of administration during the phase as it is understood by the CiA 425 CANopen standard [CiA 425 CANopen]. Exact timing of suspend/resume events can be documented in TID 11022 Imaging Agent Administration Injector Events. |
|
|
There will be one item for each activity that is administering an agent during this phase. The value multiplicity of Row 5 shall be the same between the phases of a multiphase administration and shall not exceed the value of TID 11007 (Imaging Agent Administration Step) Row 15 (EV (130219, DCM, "Number of Injector Heads")), if present. |
|
|
Datetime that the earliest syringe/pump starts administering. |
|
|
Total duration of this phase starting from where the earliest syringe/pump starts administering until the last syringe/pump ends administering. |
|
|
Imaging Agent Administration Injector Phase Identifier is the injector phase identifier presented to the user during administration. There are no definitions/restrictions made for being ordinal numberings, but it may be "1" for the first phase, etc. |
| DICOM PS3.16 2026b - Content Mapping Resource |
|---|