DICOM PS3.16 2026c - Content Mapping Resource

CID 6033 Malignant Pathology Code from BI-RADS®

Note

From BI-RADS® Third Edition, with Addendum 3.1 (National Mammography Database,F110)

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

MalignantPathologyCodeFromBIRADS

FHIR Keyword:

dicom-cid-6033-MalignantPathologyCodeFromBIRADS

Type:

Extensible

Version:

20250401

UID:

1.2.840.10008.6.1.363

Table CID 6033. Malignant Pathology Code from BI-RADS®

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

11671000

Adenoid cystic carcinoma

M-82003

C0010606

DCM

111300

Axillary node with lymphoma

DCM

111301

Axillary nodal metastases

SCT

57141000

Apocrine adenocarcinoma

M-84013

C0334346

SCT

39000009

Angiosarcoma

M-91203

C0018923

DCM

111307

Basal cell carcinoma of nipple

DCM

111303

Blood vessel (vascular) invasion

SCT

72495009

Mucinous adenocarcinoma (Colloid carcinoma)

M-84803

C0007130

DCM

111304

Carcinoma in children

SCT

1163016002

Chondrosarcoma

C0008479

DCM

111305

Carcinoma in ectopic breast

DCM

111306

Carcinoma with endocrine differentiation

SCT

78197004

Comedocarcinoma (intraductal)

M-85012

C0334369

SCT

189336000

Carcinoma in situ of breast

D1-F3507

C0154084

SCT

22694002

Carcinoma with metaplasia

M-85733

C0334396

DCM

111309

Cartilaginous and osseous change

DCM

111310

Carcinoma in pregnancy and lactation

SCT

63264007

Carcinosarcoma

M-89803

C0007140

DCM

111312

Intraductal comedocarcinoma with necrosis

DCM

111341

Intraductal carcinoma, high grade

DCM

111313

Intraductal carcinoma, low grade

SCT

128696009

Intraductal carcinoma micro-papillary

M-85072

C1266080

SCT

53654007

Fibrosarcoma

M-88103

C0016057

SCT

74280008

Glycogen-rich carcinoma

M-83153

C0334319

SCT

128736003

Hemangiopericytoma

M-88150

C1266119

SCT

1163005009

Hodgkin's lymphoma

C0019829

SCT

30156004

Invasive cribriform carcinoma

M-82013

C0205643

DCM

111315

Intracystic papillary carcinoma

SCT

82711006

Infiltrating duct carcinoma

M-85003

C1412014

DCM

111316

Invasive and in-situ carcinoma

SCT

89740008

Invasive lobular carcinoma

M-85203

C0206692

SCT

32968003

Inflammatory carcinoma

M-85303

C0334385

SCT

25910003

Papillary carcinoma (invasive)

M-80503

C0007133

DCM

111318

Leukemic infiltration

SCT

1163022006

Leiomyosarcoma

C0023269

SCT

1162815008

Liposarcoma

C0023827

SCT

3839000

Lipid-rich (lipid-secreting) carcinoma

M-83143

C0334318

DCM

111320

Lympathic vessel invasion

SCT

1163043007

Lymphoma

C0024299

DCM

111322

Occult carcinoma presenting with axillary lymph node metastases

DCM

111323

Metastatic cancer to the breast

DCM

111324

Metastatic cancer to the breast from the colon

DCM

111325

Metastatic cancer to the breast from the lung

DCM

111326

Metastatic melanoma to the breast

DCM

111327

Metastatic cancer to the breast from the ovary

DCM

111328

Metastatic sarcoma to the breast

SCT

32913002

Medullary carcinoma

M-85103

C0206693

DCM

111329

Multifocal intraductal carcinoma

DCM

111330

Metastatic disease to axillary node

SCT

34360000

Malignant fibrous histiocytoma

M-88303

C0334463

DCM

111332

Multifocal invasive ductal carcinoma

DCM

111333

Metastasis to an intramammary lymph node

DCM

111334

Malignant melanoma of nipple

SCT

1172592001

Non-Hodgkin's lymphoma

C0024305

SCT

126510002

Neoplasm of the mammary skin

D0-F035F

C1290094

SCT

1163405004

Osteosarcoma

C0029463

SCT

10376009

Papillary carcinoma in-situ

M-80502

C0334242

SCT

2985005

Paget's disease, mammary (of the nipple)

M-85403

C0030185

SCT

1187107005

Plasmacytoma

C0032131

SCT

87913009

Phyllodes tumor, malignant

M-90203

C0600066

DCM

111338

Recurrent malignancy

SCT

87737001

Signet ring cell carcinoma

M-84903

C0206696

DCM

111340

Squamous cell carcinoma of the nipple

SCT

110451006

Spindle cell nodule (tumor)

M-78190

C0333821

SCT

41919003

Secretory (juvenile) carcinoma of the breast

M-85023

C0334371

SCT

1162767002

Squamous cell carcinoma

C0007137

SCT

4631006

Tubular adenocarcinoma

M-82113

C0205645


DICOM PS3.16 2026c - Content Mapping Resource