| DICOM PS3.3 2026c - Information Object Definitions |
|---|
Table C.7-5b specifies the Attributes of the Clinical Trial Series Module, which identify a Series in the context of a clinical trial or research.
Table C.7-5b. Clinical Trial Series Module Attributes
|
The name of the institution that is responsible for coordinating the medical imaging data for the clinical trial or research. See Section C.7.3.2.1.1. |
|||
|
An identifier of the Series in the context of a clinical trial or research. See Section C.7.3.2.1.2. |
|||
|
Identifier of the Assigning Authority that issued the Clinical Trial Series ID. |
|||
|
A description of the Series in the context of a clinical trial or research. See Section C.7.3.2.1.2. |
The Clinical Trial Coordinating Center Name (0012,0060) identifies the institution responsible for coordinating the collection of images and associated data for subjects enrolled in the clinical trial or research.
The Clinical Trial Series ID (0012,0071) and Clinical Trial Series Description (0012,0072) can be used to identify and describe a Series within the context of a clinical trial or research without requiring the replacement of the Values in Series Number (0020,0011) and Series Description (0008,103E) in the General Series Module, whose manufacturer or user provided values may be relevant and important to retain.
| DICOM PS3.3 2026c - Information Object Definitions |
|---|