File Set Identification Module
|
|
File-set ID
|
(0004,1130)
|
GENERATED
|
|
|
|
|
|
|
Specific Character Set of File-set Descriptor File
|
(0004,1142)
|
GENERATED
|
|
|
|
|
|
|
Directory Information Module
|
|
Offset of the First Directory Record of the Root Directory Entity
|
(0004,1200)
|
GENERATED
|
|
|
|
|
|
|
Offset of the Last Directory Record of the Root Directory Entity
|
(0004,1202)
|
GENERATED
|
|
|
|
|
|
|
File-set Consistency Flag
|
(0004,1212)
|
GENERATED
|
|
|
|
|
|
|
Directory Record Sequence
|
(0004,1220)
|
GENERATED
|
|
|
|
|
|
|
>Offset of the Next Directory Record
|
(0004,1400)
|
GENERATED
|
|
|
|
|
|
|
>Record In-use Flag
|
(0004,1410)
|
GENERATED
|
|
|
|
|
|
|
>Offset of Referenced Lower-Level Directory Entity
|
(0004,1420)
|
GENERATED
|
|
|
|
|
|
|
>Directory Record Type
|
(0004,1430)
|
GENERATED
|
|
|
|
|
|
|
>Referenced File ID
|
(0004,1500)
|
GENERATED
|
|
|
|
|
|
|
>Referenced SOP Class UID in File
|
(0004,1510)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Referenced SOP Instance UID in File
|
(0004,1511)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Referenced Transfer Syntax UID in File
|
(0004,1512)
|
SRC_INSTANCE
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Patient Keys
|
|
>Specific Character Set
|
(0008,0005)
|
GENERATED
|
|
|
|
|
|
|
>Patient's Name
|
(0010,0010)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Patient ID
|
(0010,0020)
|
SRC_INSTANCE
|
|
|
|
|
|
|
…
|
|
|
|
|
|
|
|
|
Study Keys
|
|
>Study Date
|
(0008,0020)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Study Time
|
(0008,0030)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Study Description
|
(0008,1030)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Study Instance UID
|
(0020,000D)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Study ID
|
(0020,0010)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Accession Number
|
(0008,0050)
|
SRC_INSTANCE
|
|
|
|
|
|
|
…
|
|
|
|
|
|
|
|
|
Series Keys
|
|
>Specific Character Set
|
(0008,0005)
|
GENERATED
|
|
|
|
|
|
|
>Modality
|
(0008,0060)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Series Instance UID
|
(0020,000E)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Series Number
|
(0020,0011)
|
SRC_INSTANCE
|
|
|
|
|
|
|
…
|
|
|
|
|
|
|
|
|
Image Keys
|
|
>Specific Character Set
|
(0008,0005)
|
GENERATED
|
|
|
|
|
|
|
>Instance Number
|
(0020,0013)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Samples per Pixel
|
(0028,0002)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Photometric Interpretation
|
(0028,0004)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Rows
|
(0028,0010)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Columns
|
(0028,0011)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Bits Allocated
|
(0028,0100)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Bits Stored
|
(0028,0101)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>High Bit
|
(0028,0102)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Pixel Representation
|
(0028,0103)
|
SRC_INSTANCE
|
|
|
|
|
|
|
…
|
|
|
|
|
|
|
|
|
SR Document Keys
|
|
>Specific Character Set
|
(0008,0005)
|
GENERATED
|
|
|
|
|
|
|
>Instance Number
|
(0020,0013)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Completion Flag
|
(0040, A491)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Verification Flag
|
(0040, A493)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Content Date
|
(0008,0023)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Content Time
|
(0008,0033)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Verification DateTime
|
(0040,A030)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>Concept Name Code Sequence
|
(0040,A043)
|
SRC_INSTANCE
|
|
|
|
|
|
|
>>Code Value
|
(0008,1000)
|
|
|
|
|
|
|
|
>>Coding Scheme Designator
|
(0008,1002)
|
|
|
|
|
|
|
|
>>Coding Scheme Version
|
(0008,1003)
|
|
|
|
|
|
|
|
>>Code Meaning
|
(0008,1004)
|
|
|
|
|
|
|