DICOM PS3.2 2026d - Conformance

N.8.2 External Network Requirements

Table N.8-1 describes additional non-DICOM network protocols that are used by <Product>.

[From this table, delete any Profiles/Actors/Transactions that are not supported at all.If the Profile is supported using a secure mechanism use Y for yes in the "Security Support" column, otherwise use N for No.]

Table N.8-1. External Network Requirements

Profile

Actor

Transaction

Protocol Used

RFCs

Security Support

Reference

Basic Time Synchronization

NTP Server

Maintain Time

NTP

RFC5905;

<<RFC5906

RFC8633>>

N.11.1.1

Find NTP Servers

NTP

RFC5905;

<<RFC5906

RFC8633>>

N.11.1.1

NTP Client

Maintain Time

NTP

RFC5905;

<<RFC5906

RFC8633>>

N.11.1.1

Find NTP Servers

NTP

RFC5905;

<<RFC5906

RFC8633>>

N.11.1.1

SNTP Client

Maintain Time

SNTP

RFC2030

N.11.1.1

DHCP Server

Find NTP Servers

DHCP

RFC2131;

RFC2132;

RFC2563

N.11.1.1

DHCP Client

Find NTP Servers

DHCP

RFC2131;

RFC2132;

RFC2563

N.11.1.1

Basic Network Address Management

DHCP Server

Configure DHCP Server

-

-

N.11.1.2

Find and Use DHCP Server

DHCP

RFC2131;

RFC2132;

RFC2563

N.11.1.2

Maintain Lease

DCP

RFC2131;

RFC2132

N.11.1.2

Resolve Hostname

DNS

RFC1035;

RFC2181

N.11.1.2

DDNS Coordination

DNS

RFC2136

N.11.1.2

DHCP Client

Find and Use DHCP Server

DHCP

RFC2131;

RFC2132;

RFC2563

N.11.1.2

Maintain Lease

DHCP

RFC2131;

RFC2132

N.11.1.2

DNS Server

DNS Coordination

DNS

RFC2136;

<<RFC4033

RFC4034

RFC4035>>

N.11.1.2

Resolve Hostname

DNS

RFC1035;

RFC2181;

<<RFC4033

RFC4034

RFC4035>>

N.11.1.2

DNS Client

Resolve Hostname

DNS

RFC1035;

RFC2181;

<<RFC4033

RFC4034

RFC4035>>

N.11.1.2

Application Configuration Management

LDAP Server

Query LDAP Server

LDAP

RFC2251

N.11.1.3

Update LDAP Server

LDAP

RFC2251

N.11.1.3

Maintain LDAP Server

LDAP

RFC2849

N.11.1.3

LDAP Client

Find LDAP Server

LDAP

RFC2181;

RFC2219;

RFC2782

N.11.1.3

Query LDAP Server

LDAP

RFC2251

N.11.1.3

Update LDAP Server

LDAP

RFC2251

N.11.1.3

DNS Server

Find LDAP Server

LDAP

RFC2181;

RFC2219;

RFC2782

N.11.1.3

DNS Service Discovery

DNS Server

Find DICOM Service

DNS

RFC2136;

RFC2181;

RFC2219;

RFC2782;

RFC6762;

RFC6763;

RFC8553;

<<RFC4033

RFC4034

RFC4035>>

N.11.1.4

DNS Client

Find DICOM Service

DNS

RFC2136;

RFC2181;

RFC2219;

RFC2782;

RFC6762;

RFC6763;

RFC8553;

<<RFC4033

RFC4034

RFC4035>>

N.11.1.4

[Any additional profile]


DICOM PS3.2 2026d - Conformance