
Version 1.09, August 9, 2002
The purpose of this document is to provide a summary of the current activities and future directions of the DICOM standard. The content of the document is largely based on information submitted by individual working group chairs. WG10 will update this document on an annual basis and submit it for review and approval by the DICOM Committee at the committee’s annual RSNA meeting.
The introduction of digital medical image sources in the 1970’s and the use of computers in processing these images after their acquisition led the American College of Radiology (ACR) and the National Electrical Manufacturers Association (NEMA) to form a joint committee in order to create a standard method for the transmission of medical images and their associated information. This committee, formed in 1983, published in 1985 the ACR-NEMA Standards Publication No. 300-1985. Prior to this, most devices stored images in a proprietary format and transferred files of these proprietary formats over a network or on removable media in order to perform image communication. While the initial versions of the ACR-NEMA effort (version 2.0 was published in 1988) created standardized terminology, an information structure, and unsanctioned file encoding, most of the promise of a standard method of communicating digital image information was not realized until the release of version 3.0 of the Standard in 1993. The release of version 3.0 saw a name change, to Digital Imaging and Communications in Medicine (DICOM), and numerous enhancements that delivered on the promise of standardized communications.
The DICOM standard now specified a network protocol utilizing TCP/IP, defined the operation of Service Classes beyond the simple transfer of data, and created a mechanism for uniquely identifying Information Objects as they are acted upon across the network. DICOM was also structured as a multi-part document in order to facilitate extension of the Standard. Additionally, DICOM defined Information Objects not only for images but also for patients, studies, reports, and other data groupings. With the enhancements made in DICOM (Version 3.0), the Standard was now ready to deliver on its promise not only of permitting the transfer of medical images in a multi-vendor environment, but also facilitating the development and expansion of picture archiving and communication systems (PACS) and interfacing with medical information systems.
The DICOM Standards Committee exists to create and maintain international standards for communication of biomedical diagnostic and therapeutic information in disciplines that use digital images and associated data. The goals of DICOM are to achieve compatibility and to improve workflow efficiency between imaging systems and other information systems in healthcare environments worldwide. DICOM is a cooperative standard. Therefore, connectivity works because vendors cooperate in testing via scheduled public demonstration, over the Internet, and during private test sessions. Every major diagnostic medical imaging vendor in the world has incorporated the standard into their product design and most are actively participating in the enhancement of the Standard. Most of the professional societies throughout the world have supported and are participating in the enhancement of the standard as well.
DICOM is used or will
soon be used by virtually every medical profession that utilizes images within
the healthcare industry. These include
cardiology, dentistry, endoscopy, mammography, opthamology, orthopedics,
pathology, pediatrics, radiation therapy, radiology, surgery, etc. DICOM is even used in veterinary medical
imaging applications.
The DICOM Standard addresses multiple levels of the ISO OSI network model and provides support for the exchange of information on interchange media. DICOM currently defines an upper layer protocol (ULP) that is used over TCP/IP (independent of the physical network), messages, services, information objects and an association negotiation mechanism. These definitions ensure that any two implementations of a compatible set of services and information objects can effectively communicate.
Independence from the underlying network technology allows DICOM to be deployed in many functional areas of application, including but not limited to communication within a single site (often using various forms of Ethernet), between sites over leased lines or virtual private networks (VPNs), within a metropolitan area (often using ATM), across dial-up or other remote access connections (such as by modem, ISDN or DSL), and via satellite (with optimized protocol stacks to account for increased latency).
At the application layer, the services and information objects address five primary areas of functionality:
· Transmission and persistence of complete objects (such as images, waveforms and documents),
· Query and retrieval of such objects,
· Performance of specific actions (such as printing images on film),
· Workflow management (support of worklists and status information) and
· Quality and consistency of image appearance (both for display and print).
DICOM does not define an architecture for an entire system; nor does it specify functional requirements, beyond the behavior defined for specific services. For example, storage of image objects is defined only in terms of what information must be transmitted and retained, not how images are displayed or annotated. DICOM can be considered as a standard for communication across the “boundaries” between heterogeneous or disparate applications, devices and systems.
The services and objects that are defined in DICOM are designed to address specific, real-world applications (such as the performance of an imaging study on an acquisition device). As such, DICOM is not a general-purpose tool for distributed object management. In general, information is transferred “in bulk” according to a “document” paradigm.
By contrast, general-purpose standards for distributed object or database management generally provide lower level, more atomic access to individual attributes. Though the DICOM standard does provide the so-called “normalized” services for patient and study management, these have not proven popular, and the “composite”, document-oriented, services have prevailed. This is mostly likely a consequence of the natural division of functionality between different vendors, devices and applications. For example, the ability to “set” or “change” a patient’s name is generally implemented in a proprietary and centralized manner. To safely distribute responsibility for such a change across boundaries between different applications requires more underlying support than DICOM currently possesses (such as support for transactions and two-phase commitment).
At the present time, the pressing needs in DICOM (as indicated by the priorities of the various working groups) are to address issues relating to security, performance, new modality technology, and workflow management. These needs are being successfully addressed using the conventional “underlying” DICOM technology. Where there are interfaces to standards based on other technologies (such as HL7 V2.x and 3), the focus for harmonization is on a shared “information model”. It may be the case that the nature of the underlying technology needs to be revisited in the future, whether it is to make use of more sophisticated off-the-shelf distributed object management tools such as CORBA, or less sophisticated encoding tools such as XML. However, the current priority is to address improvements in functionality to better meet the needs of the end-user, rather than to adopt an alternative technology for the sake of it. This priority is continually reinforced by a desire to remain compatible with the installed base of equipment.
When specific new technology is required, such as in support of new features such as security and compression, the strategy is to adopt proven international, industry or de facto standards. Accordingly, network confidentiality and peer authentication in DICOM are provided by the use of either TLS (an Internet standard) or ISCL (an ISO-based standard). Similarly, rather then develop medical-image-specific compression schemes, DICOM adopts standards developed by ISO/IEC JTC 1/SC 29/WG 1 such as JPEG and JPEG 2000. For interchange media, standard file systems compatible with conventional software (such as ISO 9660 and UDF) are used.
Throughout the development of DICOM, much attention was devoted to establishing working relationships with other related standard initiatives throughout the world. The initial version of the standard leveraged prior work by ASTM. The Internet protocol TCP/IP was adopted in 1993. In the nineties, solid cooperation with CEN, the European Committee for Standardization, resulted in a number of jointly developed supplements. In parallel, the convergence of a Japanese interchange media format (IS&C) with DICOM required much joint work where JIRA, the Japan Industries Association of Radiological Systems played a major role. In the USA, DICOM participated in the early coordination efforts for healthcare standards with the ANSI-HISBB from which DICOM adopted a harmonized patient name structure, and started progressively to define links with HL7. This cooperation has now entered in a very active phase with the creation, in 1999, of a joint DICOM-HL7 working group. Finally, it was a logical step for DICOM to establish a Type A liaison with the ISO Technical Committee 215 at its creation in 1999. ISO TC 215 has decided not to create an imaging working group, but to rely on DICOM for bio-medical imaging standards.
DICOM is also focusing its attention to the evolution of standards linked to the Internet. DICOM strategy is to integrate Internet Recommendations as soon as they are stable and largely disseminated in consumer commercial products. In this evolution, much care is taken to ensure that the consistency of the DICOM standard is maintained with its large installed base. DICOM already uses standard healthcare enterprise intranets and soon the e-mail exchange of DICOM objects (Standard MIME type) should be possible. It is clear that the use of DICOM objects and services in commonly used information technology applications will grow in the future.
DICOM is a standards organization administered by the NEMA Diagnostic Imaging and Therapy Systems Division. The complete bylaws of the DICOM Standards Committee are available on the NEMA web site at www.nema.org. Working groups of the DICOM Committee perform the majority of work on the extension of and corrections to the Standard. Working groups are formed by the DICOM Committee to work on a particular classification of tasks. Once formed, working groups petition the DICOM Committee to approve work items for which the working group will execute the plan delineated in the work item. Once the output of a work item (generally a supplement or correction proposal) has been completed, it is submitted to Base Standards Working Group (WG6), for their review. Supplements to the standard then go through a public comment period, after which the DICOM Committee authorizes the supplement for letter ballot by DICOM members. Letter ballots require approval by two-thirds of those voting affirmative or negative and return of more than one-half of the ballots sent to members in good standing relative to letter ballots. Since the working groups perform the majority of work on the extension of and corrections to the Standard, the current status and future directions of the DICOM standard are best represented by review of each working group.
|
|
|
Secretariat NEMA
Secretary Howard Clark, NEMA
Vendor Co-Chair David Clunie, M.D. RadPharm
User Co-Chair Lloyd Hildebrand, M.D., American Academy of Ophthalmology
Date of Last Update: March 6, 2002
The DICOM Standards Committee exists to create and maintain international standards for communication of bio-medical diagnostic and therapeutic information in disciplines that use digital images and associated data. The goals of DICOM are to achieve compatibility and to improve workflow efficiency between imaging systems and other information systems in healthcare environments worldwide.
Secretariat NEMA
Secretary Howard Clark, NEMA
Co-Chair Jon Elion, MD, FACC, Heartlab
Co-Chair Harry Solomon, GE Medical Systems
Date of Last Update: July 6, 2001
To develop standards for the digital interchange of the cardiovascular images, physiologic waveforms and core clinical information, which characterize a patient undergoing a catheterization procedure.
The WG-01 roadmap is a long-term strategy to specify information objects and services to fully digitize and integrate data flow within and beyond the catheterization laboratory. The ultimate goal is a comprehensive digital cardiovascular record for the patient, of which the cath lab record is a significant part.
The cath lab is a multi-modality mix of many types of equipment from many different manufacturers. Moreover, cardiovascular medicine requires consultation and interaction between many medical disciplines. Standardized data interchange is critical in this environment.
The initial WG-01 work effort was directed toward the definition of X-ray Angiography (XA) image exchange, including both a Basic Cardiac profile and a 1024 profile for media-based exchange. The next step was the development of DICOM cardiovascular waveform exchange, with specializations for hemodynamics, cardiac electrophysiology, and electrocardiography. Completing the data acquisition aspect is definition of intra-vascular ultrasound (IVUS) image exchange.
The next level of integration involves definition of various structured data interchanges in the cath lab, to support the interpretation and effective use of the basic images and waveforms. This structured data includes procedure logs, quantitative and qualitative measurements, and clinical reports, and requires specialization of the DICOM Structured Report services.
Finally, the overall workflow management of the cath lab within the cardiology department and within the larger institution will be evaluated. This will be done with regard to adapting the DICOM Study Management services to the particular needs of cardiology practice (as distinct from radiology).
· Completion of DICOM standards for IVUS image exchange, currently in Public Comment.
· Specification of IODs, Templates, and SOP Classes for cath lab structured reports:
o Hemodynamics
o Quantitative Coronary and Ventricular Analysis
o Cath Lab Procedure Log
o Electrocardiography
o Cath Lab Clinical Report
· Drafts templates are available for prototyping and demonstration.
· Technical support for public demonstrations of DICOM for the cardiovascular community.
WG-01 plans to meet approximately four times per year for 1-2 days each, plus interim discussions by telephone conference.
· IVUS (Supplement 48)
· Cath Lab Structured Reports (pending approval)
The integrated data flow in the cath lab requires the implementation of multiple DICOM Services in the equipment, such as DICOM image and waveform interchange, and various types of structured reports. It will be important to establish a forum (not necessarily within WG-01) that will promote the adoption of comprehensive interoperation profiles for the cath lab, similar to the effort of IHE in radiology.
Further, the various types of objects must be synchronized to provide clinically meaningful and accurate data acquisition. For example, IVUS images must be accurately synchronized to ECG and audio waveforms, and to the procedure log, to post-process for 3-D reconstruction and to be able to identify the sites imaged and the acquisition context. These multiple objects of different SOP classes must be effectively managed as coordinated whole, and effective technical mechanisms for inter-equipment synchronization need to be developed.
Most of WG-01’s current work is based on DICOM Structured Reporting, which is new and as yet unproven in practice. This presents several risks to the work of WG-01:
· DICOM SR relies extensively on coded terminology and templates. There remain both practical and theoretical questions regarding the processes for development, distribution, and maintenance of code sets and templates for the cath lab SR information objects.
· DICOM SR does not currently support a means of controlling presentation, similar to Grayscale Presentation State for images. Rendering of SR is a major area for development, and substantial inter-product differences in presentation may affect the acceptance of SR by the clinical community.
· Tool support for DICOM SR is still rudimentary. This may be an impediment to adoption of SR information exchange.
· SR involves formalizing and standardizing much clinical knowledge, which has hitherto been informal or ad hoc. Development of SR templates thus requires much more involvement from the clinical community, as well as willingness by that community to adopt standardized formats over custom local formats.
The WG-01 effort has the potential to significantly improve the operation of the catheterization laboratory, with consequent improvement in both patient care and facility administration. Major improvements in lab productivity and clinical response time to emergent cardiovascular conditions can result from integrated data flow within and between the cath department and the hospital. This integration includes both data moving into the lab (e.g., demographics, blood lab results), and data moving out (e.g., images and reports to the emergency department). The structured coding of cath lab data can facilitate analysis and improvement of patient outcomes, quality assurance, automated support for billing, as well as administrative analysis of organizational effectiveness. Beyond the institution, this data can support broad clinical research and regional or national clinical data registries.
The work effort must studiously adhere to the roadmap for progressive and incremental integration of the cath lab data flow, focusing on pragmatic next steps in the standardization process which bring real benefit to the cardiovascular user community (clinicians and administrators). A major challenge will be developing standards that facilitate the conversion of legacy cath lab systems to DICOM standard data interchange. The standards must be effective even in environments that have a mix of fully DICOM-compliant subsystems and legacy systems that may support only a limited subset of DICOM functionality.
Strong participation in WG-01 from the European Society of Cardiology, as well as the American College of Cardiology, has helped ensure a broad international applicability of the work. It is critical to maintain this liaison and engagement.
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair – Pro Tem Heinz
Blendinger
Date of Last Update: August 5, 2002
Secretariat NEMA
Secretary Richard Eaton, NEMA
Chair Jeff Pohlhammer, Philips Medical Systems
jeff.pohlhammer@cle.philips.com
Date of Last Update: March 28, 2002
To develop standards for the digital interchange of Nuclear Medicine and PET images.
Potential work items would be generation of CPs to address the goals listed below.
Working with the Society for Nuclear Medicine and the joint task force on cardiac NM, address issues with the NM IOD. These include:
· Identified the SNOMED terms that were already in use for required attributes in the NM IOD and made sure they are included in Part 16. These are included in the latest draft of the standard.
· Generated CP to define SNOMED terms that can be used in the View Code Sequence to identify cardiac image views of Short-Axis, Vertical Long Axis, and Horizontal Long Axis. The CP is in process.
· Discussions for clarification of the NM IOD are ongoing.
None.
None, yet.
Outside groups, such as the Society of Nuclear Medicine have recently become more interested in DICOM, and have expressed concerns related to the issues mentioned above. This presents an opportunity to work with the SNM, and other related groups, to address these issues in a manner consistent with the architecture of the current NM IOD. The challenge is to do so in a timely manner.
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair Alan Rowberg, MD, University of Washington (ACR)
Date of Last Update: July 6, 2001
To provide data compression facilities for the DICOM standard and to advise on application or object-related definitions of data compression parts of the DICOM Standard created by other working groups.
Develop appropriate DICOM transfer syntaxes for JPEG 2000 when it is released.
· Expected release of JPEG 2000 Part 1 is December 2000
Expectations for the next few years, after the current work items are finished:
· JPEG 2000 (ISO 15444-1 CD stage)
o lossless & lossy progressive wavelet
· MPEG-2 (WG-12)
· M-JPEG 2000?
· Retirement of unused 10918-1 processes
Use of Future Image Schemes
· Network
o any transfer syntax can be negotiated
o uncompressed default baseline
o compressed baselines?
· Media
o general purpose uncompressed
o XA/CT/MR 10918-1; US RLE & 10918-1
o future - Mammo DVD JPEG-LS ? 2000 ?
Future schemes for other data
· Single bit (scanned document)
o CCITT Fax
o JBIG
o JBIG2
· Overlays
· Waveforms (if not combined with images)
· Audio
· Future JPEG 2000 work
Beyond JPEG 2000 Part 1 (ISO 15444-1)
· Part 2 extensions (may not be royalty free)
· 3D transform (multi-slice or multi-spectral)
· Line/block based coders (major IPR issues)
· More Region-of-Interest modes
· Part 2 lags 6-9 months behind part 1
We plan to serve a maximal number of modalities and clinical situations, with support for growing areas such as telemedicine and the use of new technologies such as DVD. We shall develop the appropriate DICOM transfer syntaxes for JPEG 2000 when it is released.
Compression that is already available in the standard:
JPEG (ISO 10918-1) - all processes
· lossy (DCT)
· lossless
· sequential, progressive
· Huffman, arithmetic entropy coders
RLE (aka TIFF Packbits)
· ultrasound
JPEG-LS (ISO 14495-1) (DICOM CP-174)
· lossless, lossy (“near-lossless”)
Tracking the progress of the JPEG 2000 standard, evaluating its performance in medical imaging, and planning to develop appropriate DICOM transfer syntaxes for JPEG 2000 when it is released.
The risk of JPEG 2000 not issuing as an international standard is low. We expect no problems in creating the proper transfer syntaxes. The success of other items will depend on support from the DICOM vendor community.
In the area of multi-frame and 3D compression, WG-12 is making progress on the incorporation of MPEG compression into the DICOM Standard. We now have a technical expert on MPEG to assist us in our work. The first phase of our work is to determine whether MPEG really offers considerably greater compression ratios and/or performance for Ultrasound cine than Lossy JPEG or JPEG 2000 compression. We have been concentrating on MPEG2 and have found that one of the key issues is the limited capability of most decoders. Most current MPEG2 decoders can only handle certain image frame sizes. We need to investigate this issue further to determine if we want to create a transfer syntax for MPEG2 with restricted allowable image frame sizes.
DICOM has cross-representation to JPEG 2000.
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair David Clunie, ComView Corporation
Date of Last
Update: June 12,
2001
To develop DICOM standards for interchange media.
Potential work items with respect to new types of media:
· Larger capacity MOD media are widely used but not actually recognized in the standard, both for 90mm and 130mm
Potential work items with respect to secure media:
· WG 14 has an assigned work item to develop media security proposals, currently at either the file or attribute level; the possibility of using a secure file-system has been raised and OSTA has begun work on Secure UDF; should this become a reality then WG-05 will need to review the implications of incorporating Secure UDF in PS 3.10, 3.11 and 3.12
Potential work items with respect to the DICOMDIR:
· Opportunities exist to improve or replace the DICOMDIR to better support:
o Large number of small files
o Longer file names (such as those based on UIDs)
o A “.dcm” extension
o Security features
Potential work items with respect to archival
· At present DICOM only defines interchange media, not archive media
· DICOM PS 3.10 files (+/- DICOMDIR) are frequently used on optical archive media, both removable and in jukeboxes
· A proposal from the VA has been received to consider defining an “archive migration format” to facilitate migrating studies from obsolete archives to new devices
· Consideration of DVD media beyond existing DVD-RAM support
· Consideration of 130mm 4.xGB CT/MR profile proposal
· Consideration of 90mm > 640MB US profile proposal
· Consideration of Secure UDF proposal (with WG 14)
· Supplement 40 completed May 2001, after conversion to support DVD-RAM only
· Progress on DVD-R stalled awaiting developments in optical media industry, specifically:
· More than one DVD-R vendor (expected 3Q 2001)
· Support/requirement from application-specific WG
· None
Roadmap - new types of media:
· MOD vendors are few, especially in 90mm
· Larger capacity 130mm based on 512 bytes per sector and FAT 16 file system are extremely wasteful of space (e.g. 4.1GB vs. 5.2GB); use of non-partitioned file system causes problems with NT but is required for backward compatibility
Roadmap - secure media:
· Secure UDF effort has just begun, has yet to attract widespread OS support, and place role in the consumer market is unclear; there is talk of “special drives” with hardware keys which would not be acceptable for medical apps (could not leverage consumer volume)
Roadmap - DICOMDIR:
· Any significant changes would impair compatibility with installed base, and suggested changes may only be of benefit to implementers rather than users
Roadmap – archival:
· Choices of archive media and format are usually based on such factors as access time, transfer rate, durability and cost, rather than interoperability, and DICOM has never been considered to have a role in standardizing these choices
· Migrating “internal” media from a decommissioned archive is a recognized and difficult problem, but still may not justify standardization
· Leverage the popularity of consumer optical media formats like DVD, when versions that can be written actually do become popular
· Leverage the popularity of consumer logical file system formats like UDF
· Leverage consumer and internet standards for media security solutions, such as Secure UDF
An “informal” liaison with OSTA exists to harmonize efforts with respect to UDF, MOD and DVD
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair Andrei Leontiev, IDX Systems Corporation
Date of Last
Update: June 12,
2001
WG-06 maintains the overall consistence of the DICOM standard. Some of the responsibilities include:
· Execution the DICOM Maintenance Process (Correction Proposals). The process is used to make “corrections and minor changes” to the current versions of the Standard.
· Provision of technical coordination and guidance for all WGs. This includes review and official approval before the Public Comment, Letter Ballot, and Final Text draft releases of all supplements.
· Development of Supplements to the standard related to Print, Image Management, etc.
· Coordination of joint development efforts with CEN, JIRA, and Medis DC.
· Coordination with NEMA for the publication of DICOM.
On-going DICOM Maintenance Process:
· Correction Proposals submitted by the members and other interested parties will continue to be considered by the WG-06
· All Correction Proposals accepted by WG-06 and designated for inclusion into voting package, will be published on the FTP server for the comments by all DICOM Committee members at least 2 weeks before the WG-06 meeting considering such voting package for Letter Ballot
Potential work items of other Working Groups:
· WG-06 will provide assistance to the working groups working on their assigned work items
· All work items (as supplements to DICOM Standard) approved by corresponding working groups will be accepted for review by WG-06 and for preparation of Letter Ballot.
· All Supplements approved by the Letter Ballot will be considered in order to prepare Final Text, with addressing of any comments received
Potential work items with respect to Workflow Management:
· WG-06 is considering potential work items that may address areas of Medical Imaging Workflow that may require development of new or improved mechanisms, in such areas as:
o Hardcopy Management
o Archive Management and Image Availability Notifications
o Support for Patient Information Reconciliation (update of information in composite instances)
Potential work items with respect to the Structured Reporting:
· SR implementations may require introduction of new or improved mechanisms to address such functionality as:
o Query/Retrieve
o Search – ability to retrieve information from SR instances or to identify SR instances with particular content in the document content tree
Potential work items with respect to Conformance:
· Development of Conceptual Model and XML Schema for DICOM Conformance Statement, example of XML-based statements
· Finalize work on retirement of obsolete parts of the Standard (Part 9, Storage Commitment Pull Model)
· Revision of Part 2 - DICOM Conformance
· Consideration of Configuration Management
The following Supplements developed by WG-06 have recently been completed and are in Final Text :
· Supplement 53
· Supplement 54
· Supplement 57
· Supplement 59
· Supplement 64 – Revised Part 2 (Conformance) – Released for Public Comment
· Supplement 44 – Retirement of Part 9
· Supplement 67 – Configuration Management
· Supplement 68 – Retirement of Storage Commitment Pull Model
Progress of the IHE initiative is being regularly reviewed by WG-06.
Secretariat NEMA
Secretary Stephen
Vastagh, NEMA
Chair David
Murray, TomoTherapy Incorporated
Date of Last Update: April 23, 2002
To develop and maintain radiotherapy information objects for the DICOM Standard and promote their implementation and acceptance within the industry.
In the next few years, the RT-specific objects in the standard need to be maintained to completely stabilize existing implementations. Extensions to existing objects have been and will be introduced to accommodate new techniques. Ion therapy is being addressed, and work in this emerging area will continue. Another major goal is to address how workflow in the RT department can be enhanced using existing and upcoming DICOM objects and concepts.
The primary work of WG7 involves maintenance of existing RT-specific DICOM objects, correcting issues discovered during detailed implementation and introducing minor extensions to deal with new techniques and approaches in radiotherapy. A number of Change Proposals are awaiting ratification or under development.
Supplement 11 (RT Image, RT Structure Set, RT Dose, RT Plan) and Supplement 29 (RT Treatment Record objects and Media Support) are part of the DICOM 1999 standard. Work is continuing on Supplement 74 (Radiotherapy General Purpose Worklist Extensions and Calculation Service Model).
Several CPs are under discussion. These will extend brachtherapy and external beam therapy, correct some errors and clarify wording. Work is continuing on Supplement 74 (Radiotherapy General Purpose Worklist Extensions and Calculation Service Model). Extension of DICOM to handle ion therapy is being worked on and a draft proposal exists.
Implementation of existing standardized objects is well advanced. There is no clearly identifiable risk to achieving short-term goals. Incorporation of workflow concepts into RT may depend on other working groups introducing the concepts needed by RT departments (such as studies distributed over time).
Smooth incorporation of RT procedures into DICOM workflow concepts, in particular Interpretation Worklist and Modality Performed Procedure Step.
RT objects use IEC-61217 for treatment machine descriptions and ICRU concepts for dosimetry. The DICOM patient-based coordinate system (Amendment to IEC 61217, 62C/269) also has a well-defined relationship to the IEC Patient coordinate system. IEC/TR 62266 (“Medical Electrical Equipment - Guidelines for Implementation of DICOM in Radiotherapy”) is now published. WG7 is active in review of a new IEC standard under development – IEC 62274 (“Safety of Radiotherapy Record and Verify Systems”).
Secretariat College of American Pathologists
Secretary John Kilbourne, SNOMED
Chair Frank Krickhahn, Siemens
Frank.Krickhahn@siemens.com
Date of Last Update: March 6, 2002
To develop and maintain the DICOM Structured Reporting specification, and to collaborate with DICOM working groups and other standards development committees in the development of specialized reports and other documents based on the generic SR specification.
A.
Create a set of guidelines for template creators.
B.
Support the creation of general, reusable templates
components and outlines
C.
Maintenance
of the SR infrastructure
D.
Cross-specialty
SR template creation
E.
Development
of a methodology (with a standardized graphical notation) to describe
templates.
F.
Assist
WG-20 in the integration of DICOM SR with other standards efforts, in
particular HL7, and support of SR development in the various DICOM WGs.
G. Technical support for demonstration
of SR, as required by IHE, NEMA, etc.
H. Development a process
for submitting clinical use cases and requirements for SR templates
I.
Development
of a means of specifying SR presentation
J.
Development
of a formal syntax for encoding the definition of templates and context groups
in efforts to facilitate creation of a machine-readable version of these parts
of the standard.
Kick-off meeting held June 6th
TBD
A. Identify issues retarding SR template creation
B. Identify commonalities in SR template creation in efforts to create cross modality SR template consistency
C. Identify a process for communicating work.
D. Identify WG-20 and WG-6 AHG relationship
E. Change Proposals
Secretariat American Academy of Ophthalmology
Secretary Flora Lum, M.D.
Co-Chair Lloyd Hildebrand, M.D., American Academy of Ophthalmology
Co-Chair Rainer Waedlich, IFA Systems Group
Date of Last Update: January 24, 2001
To address all issues relating to imaging and reporting of image-based studies in ophthalmic applications.
The implementation of ophthalmology relevant objects (e.g. VL, SR, U/S) will be emphasized in eye care environments. Coordinated education and demonstration projects for vendors and users will be essential to get broad adoption of the standard in eye care. Extensions/refinements to existing objects will be introduced to accommodate new techniques. Visual field and corneal topography will be addressed.
Implementation of existing standardized objects is just beginning. While there has been heightened awareness of DICOM in the vendor and user communities, many major vendors still do not participate in the standard development process or use the standard in their products.
WG-09 anticipates working closely with SNOMED in the development of structured terminology for use in Structured Reporting object for ophthalmic applications.
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair Cor
Loef, Philips Medical Systems
Chair Joel Chabriais, Societe Francaise de Radiologie
joel.chabriais@nck.ap-hop-paris.fr
Date of Last Update: July 6, 2001
To consider issues and opportunities related to the strategic evolution of DICOM; to provide liaison to other standards developing organizations; to review standards and technology in healthcare, biomedical imaging, commerce, telecommunications, and informatics; and to develop and maintain the long-term strategic plan of the DICOM Standards Committee.
· Advise the DICOM Committee on the influence of technology advances on DICOM, e.g. streaming video.
· Advise the DICOM Committee on possible actions related to Healthcare security regulations.
· Coordinate the relation between DICOM and ISO TC 215.
· Advise the DICOM Committee about the relation and possible actions resulting from the IHE (Integrating the Healthcare Enterprise) initiative of RSNA and HIMSS.
· Explore and guide the evolution of DICOM Structured Reporting in relation to the progress in HL7 Clinical Document Architecture and web-developments such as XML.
· Explore and advice the DICOM Committee about the influence of Web-technology on DICOM.
· Complete DICOM position paper on the relation between Structured Reporting and XML in the light of the HL7 Roadmap for Clinical Document Architecture.
· Complete DICOM Mime type (Supplement 54) and explore DICOM URL.
· Complete the 1st version of the DICOM Strategic Document.
· Advise the DICOM Committee on Coding Schemes for non-US countries.
· 1st version DICOM Strategic Document completed by Dec. 2000
See Short Term Goals
· The integration of DICOM with other standards is becoming an increasingly important point, however the maturity of such standards (e.g. HL7 V3.0) is a complex process, on which DICOM has little influence.
Challenges:
· Acceptance and development of Structured Reporting also outside the strict DICOM community.
· The rapid development of web-based distribution of healthcare information. The clear positioning of DICOM in this respect.
· HL7 Clinical Document Architecture development needs to be coordinated with DICOM SR to ensure a complementary and compatible role.
· DICOM has type-A relation to ISO TC215, and cooperates with ISO TC215 on the standards for communication of biomedical diagnostics and therapeutic information in disciplines using digital images and associated data.
· For Security, the relation to HIPAA (United States), European Union Data Protection Directive, and HPB 517 in Japan.
· CEN TC251 on Medical Informatics Standards.
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair Brad Hemminger, University of North Carolina
Date of Last
Update: March
28, 2002
To develop a display function standard and DICOM services related to image presentation objects.
· Hanging Protocols ready for public comment early 2002.
· Interactive Collaboration approved as work item June 2001. Interactive Collaboration ready for public comment by summer 2002.
·
Several other topics may be addressed. Those that have the highest interest level
are color presentation (in conjunction with WG-12, WG-21 et. al.), 3D
presentation (in conjunction with WG-17 which is addressing 3D representation),
Advanced Presentation State,
and Structured Display, which is combining presentation state with structured
reporting and potentially hanging protocols.
· Bring Hanging Protocols (Supplement 60) to Public Comment.
· Bring Interactive Collaboration (IC) to Public Comment.
· Work with DICOM working groups involved with color, to develop unified support for color presentation within DICOM, tentatively as an extension to the GSPS Standard.
· Advise WG-17 regarding 3D presentation.
· Maintenance of existing two standards (Grayscale Standard Display Function, and Grayscale Softcopy Presentation State Storage).
· Grayscale Standard Display Function (GSDF), Supplement 28, Part 14 of DICOM 1998.
· CP-200: Table correction in DICOM Part 14; Final Text, September 2000.
· Grayscale Softcopy Presentation State Storage (GSPS), Supplement 33, September 1999, incorporated into DICOM 2000.
· Demonstration of Grayscale Softcopy Presentation State and Grayscale Standard Display Function at ECR 1999.
· Demonstration of Grayscale Softcopy Presentation State, Grayscale Standard Display Function and Presentation LUT (hardcopy consistency) at RSNA 1999.
· Public availability on the NEMA server of demonstration and test software supporting Grayscale Softcopy Presentation State.
· CP-202: Revised Presentation LUT for hardcopy so that it is consistent with the rest of the standard (Softcopy Presentation LUT); Final Text, January 2001.
· Supplement 60: Hanging Protocols
· Supplement XX: Interactive Collaboration
· Achieving a unified approach to color presentation within DICOM.
· Achieving a unified approach to 3D presentation within DICOM.
· Requests for future work items will be dependent on the active participation of vendors and clinicians that perceive a need to expand the DICOM Standard in a specific area. Some items may require cooperation from other working groups, and/or a broadening of the scope of the Display working group.
· Maintaining expertise, champions, vendor and clinical participation.
· Hanging Protocols can advance and unify softcopy-reading paradigms.
· Work with WG-01 to integrate waveform representation into Hanging Protocols, and help WG-01 integrate GSPS and Hanging Protocols into waveform presentation.
· Work with WG-14 (Security) for interactive collaboration (identification of users).
· Work with WG-03, WG-12, WG-13, WG-16, WG-17, and WG-21 to define a unified color presentation.
· Work with WG-17 on 3D presentation.
· Support the use of Grayscale Softcopy Presentation State in IHE year 3 (2001-2002).
· Work with WG-08 (Structured Reporting) for Structured Display.
· GSDF refers to calibration (quality assurance and quality control) guidelines for electronic displays. Currently work is underway by AAPM Task Group 18 in this area, as well as potential work by IEC group 62B on electronic displays.
· Evaluate similarities with ITU-T.126 in preparation of Interactive Collaboration.
Secretariat NEMA
Secretary Richard Eaton, NEMA
Chair David Heaney, A.L.I. Technologies Inc.
Date of Last Update: March 6, 2002
To develop extensions to DICOM that are specific to the needs of the ultrasound imaging community. This includes all aspects of ultrasound acquisition related workflow and generated data, such as single and multi-frame images, waveform data (doppler audio, phonocardiogram, voice, etc.), and measurements.
· Work items related to ultrasound procedure reports:
o Currently adding support for Ob/Gyn, Vascular, and Echocardiography Procedure Reports.
o Support of additional Procedures Reports is to be addressed in the future.
o Existing Work Items all pertain to Structured Reports generated on the ultrasound modality itself. WG-12 may wish to address some requirements pertaining to final reports for ultrasound exams.
· Potential work items related to spatially 3 dimensional ultrasound acquisition and processing:
o This will be dependent on work completed by WG-17 that standardizes the approach for dealing with such multi-dimensional image sets.
· Work items related to ultrasound waveform data:
o Require the ability to export ECG, Doppler Audio, and Voice Audio waveform data. The DICOM Standard already defines SOP Classes for ECG and Voice Audio but support for Doppler Audio is also required.
· Addition of an informative annex to Part 4 of the DICOM Standard explaining how to implement optimal support for ultrasound staged protocol data management.
· Creating new templates and code Context Groups for ultrasound Ob/Gyn, Vascular, and Echocardiography Procedure Reports.
· Addition of the necessary measurement and observation codes to the LOINC code database required for ultrasound procedure reports.
· Addition of higher capacity 640MB and 1.3GB 90mm MOD formats to the DICOM Standard as well as their support in Ultrasound Removable Media Application Profiles.
· Acceptance of a Change Proposal that adds the Graphic Annotation Module to the existing Ultrasound Image and Multi-frame Image IODs. WG-12 members have proposed this so that color annotations can be conveyed in both Ultrasound Image and Multi-frame Image IODs. WG-12 members do not wish to use separate GSPS SOP Instances to support this or add GSPS-like support for color images.
· Support for ultrasound staged protocol data management has been added with Change Proposals, CP 201 and CP230, related to protocol and ultrasound stage codes. The goal is for the staged protocol data management informative annex defined in Supplement 45 to be approved for Public Comment in January 2002.
· Supplement 26: Ultrasound Procedure Reports is nearing Public Comment for ultrasound Ob/Gyn Procedure Reports. The goal is to have the Supplement approved for Public Comment phase in February 2002. Supplements for Vascular and Echocardiography Procedure Reports will soon follow.
· Supplement 69 has been created to add the larger capacity 90mm Media to the DICOM Standard. The goal is to have this ready for letter ballot in January 2002. This is somewhat dependent on whether the GIGAMO formatting is being made an ISO/IEC Standard, and if so, the anticipated timeline for this.
· WG-12 members consider the addition of support for Ultrasound Doppler Audio Waveform to be a low priority. For this reason no progress has been made for Supplement 56 recently.
· A Change Proposal has been proposed that will add the Graphic Annotation Module to the Ultrasound Image and Multi-frame Image IODs.
· Supplement 45: Ultrasound Protocol Data Management Informative Annex.
· WG-12 has a Work Item for Ultrasound Procedure Reports. This will result in the creation of new SR Templates and Code Context Groups for Ob/Gyn, Vascular, and Echocardiography. Supplement 26 contains Ob/Gyn reporting. Additional Supplements will be created for Vascular and Echocardiography reports.
· Supplement 56: Ultrasound Waveform Data. This is not a current priority so no recent progress has been made. WG-12 will address this Work Item again once the higher priority Structured Reporting Supplements have been completed.
· WG-12 is no longer interested in adding MPEG compression to the DICOM Standard. As such WG-12 has dropped this Work Item.
· There are still large numbers of terms that are lacking in the LOINC database. Delays in completing the codification process will result in delays in implementation of ultrasound Structured Reports or compatibility issues resulting from the use of private codes in such reports.
· Standardization of Templates and Codes for ultrasound Structured Reports offers greater opportunities for interchange of unambiguous coded measurements and observations. This will facilitate development and enhancement of data mining and research applications, as the data will no longer be interchanged only in text format.
· As detailed earlier there are still some significant gaps in our coded terminology. There is an opportunity for creating closer long-term relationships with the professional societies reviewing the coded terminology, but there is also a risk of delay due to the large amount of work still to be completed.
· Use of LOINC for the codification of ultrasound measurement and observation terminology compiled by WG-12.
![]()
Secretariat European Society of Cardiology
Secretary Pr. Dr. Med. Rudieger Simon
Co-Chairman Emmanuel Cordonnier ETIAM (pro tem)
Co-Chairman Jan Rorive, SONY (pro tem)
jan.rorive@eu.sony.com
Date of Last Update: June 25, 2002
· To extend the DICOM standard beyond still Visible Light images, with still and motion color images produced by endoscopes, microscopes, or photographic cameras.
· Address the video sequence aspects (MPEG2).
· See if other topics must be specifically addressed, like, for example, streaming video, and/or, automation of workflow based on simple acquisition modalities (one button operation based).
· To develop a new transfer syntax for existing Visible Light IODs, and, potentially, Secondary Capture IODs, in order to support MPEG-2 encoding of images.
· WG13 has been stopped its activity for months. Some global vendors in Europe and users are asking for addressing the critical video aspect.
· The new group will meet for a "kick-off" meeting in September, 2002. A formal work item will be developed and submitted for approval for the DSC September meeting.
· Addition of MPEG-2 compression to the DICOM Standard: This work will be based on the users/vendors requirements as well as the already done work on MPEG (Supplement 42).
· Come too late and too many proprietary systems are used.
· Today several manufacturers are offering medical MPEG video-recording solutions to these modalities working with visible images. All of the known manufacturers are using propriety standards. Because the build-up databases are incompatible with the DICOM standard vendors likes to propose an MPEG-2 DICOM standard. Targeted modalities are Gastro-Enterology, Laparoscopy, Orthopedics, Ophthalmology, Ear Nose Throat, Gynaecology, Bronchoscopes.
· Visible Ligth IODs are correct for static images, although not commonly used, yet. MPEG2 extension can make them attractive for vendors and users in that DICOM provides a consistent solution for both still and compressed motion images.
· MPEG-2, ISO/IEC 13818, 1996
Secretariat NEMA
Secretary Howard Clark, NEMA
how_clark@nema.org
Chair Lawrence Tarbox, Siemens Corporate Research, Inc.
Date of Last Update: April 30, 2002
To develop extensions to DICOM that address the technical details of providing secure information exchange.
· Cooperate with the SPC and other organizations in identifying and understanding:
· Specify the technical means needed to fill those holes:
1. Utilizing existing standards wherever possible;
2. Jointly developing standards where appropriate;
3. Developing DICOM-specific standards only if no appropriate alternative is available.
· Address the need to exchange audit-trail information.
· Investigate means to add Digital Signature capabilities to Structured Reports.
· Supplement 31, specifying secure connections for networks, passed letter ballot and was incorporated into the standard.
· Supplement 41, specifying a general purpose Digital Signature mechanism, passed letter ballot and was incorporated into the standard.
· Supplement 51, addressing security on interchange media, passed letter ballot.
· Supplement 55, passed letter ballot with comments. Having addressed these comments, WG 14 recommends that the supplement be adopted by WG-06.
· Audit-trail message exchange work item, which WG-14 is perusing in conjunction with HL7, IHE, SPC, and ASTM.
· Digital Signatures for Structured Reports work item, and WG-14 has started preliminary discussions with WG-08.
· The mechanisms utilized become obsolete or broken.
· Mechanisms that are appropriate for one regulatory body are inappropriate for another.
· Clearly understanding the level of security required by local and governmental regulations.
· Resolving differences between seemingly conflicting regulations from different bodies.
· Specifying mechanisms that are easily incorporated, and that do not conflict with work done by other bodies.
· DICOM security mechanisms should be coordinated with mechanisms being developed by other organizations, such as HL7 and ASTM, to create a comprehensive security package for the entire Electronic Patient Record.
Secretariat American College of Radiology
Secretary Lynne Fairobent, ACR
Co-Chair Dr. Carl Vyborny, ACR/LaGrange Memorial Hospital
Co-Chair Janet E. Keyes, R2 Technology, Inc.
Date of Last Update: June 15, 2001
To develop extensions to DICOM to support digital mammography, and the structured reporting of Computer-Aided Detection / Diagnosis (CAD) results.
The following are potential work items with respect to Structured Reporting:
· Reporting of Mammography CAD output across modalities: expansion beyond X-Ray projection into Ultrasound and/or MR breast imaging analysis.
· Reporting of CAD output results that are 3-Dimensional.
· Reporting of CAD output for additional anatomy.
The following are potential work items with respect to Image IODs:
· Addition of attributes or modules to describe DX/Mammography quality control and phantom images.
· Evaluation of the Ultrasound and MR Image IODs for completeness with respect to attributes specific to breast imaging.
· Addition of attributes or modules for energy subtraction in breast imaging.
· Use of CAD output to drive digital display devices.
· Short term: Supplement 65, Chest CAD SR, is dependent on the clinical input received toward reaching consensus on a subset of chest radiography terminology to use in describing Chest CAD output results, and assignment of codes for that terminology.
· Short term: Patient Clinical History for Breast Imaging is dependent on the work of WG-08, Structured Reporting, for the definition of general and/or common templates that can be used by multiple working groups that are dealing with representation of patient clinical history.
· Roadmap: Requests for future work items will be dependent on the active participation of vendors and clinicians that perceive a need to expand the DICOM Standard in a specific area, and support of the Secretariat for those work items. Some items may require cooperation from other working groups.
· Correction Proposal for TID 1400, Linear Measurement Template, to allow numeric measurements to be defined without requiring a reference to spatial coordinates, to Letter Ballot in June 2001.
· Supplement 65: Chest CAD SR SOP Class, to Public Comment in November 2001.
· General Mammography Report and Patient Clinical History for Breast Imaging Supplement(s), to Public Comment in January 2002.
· Add scheduling of CAD processing and the reporting of CAD output to the IHE Year 4 technical framework.
· Maintenance of the Digital Mammography X-Ray Image IOD and Mammography CAD SR IOD.
· The Digital Mammography working group was convened initially in February 1998, to ensure that Supplement 32: Digital X-Ray Supplement would meet the needs for the storage of digital mammography image objects in DICOM. The Secretariat is the American College of Radiology (ACR).
· Digital Mammography X-Ray Image Storage – For Presentation and For Processing SOP Classes in Supplement 32: Digital X-Ray Supplement, Final Text, 1 September 1998 (DICOM 1999).
· CP-193: Add Type 3 Partial View image attributes to the Mammography Image module, Final Text September 2000.
· Supplement 50: Mammography CAD SR SOP Class – an extension to DICOM to standardize the reporting of CAD results for mammography, using DICOM Structured Reporting; Final Text, May 2001.
· “Rejected for Quality Reasons” and “Quality Issue” included in Supplement 59, Key Object Selection Document, Final Text, May 2001 (in lieu of CP-192: Add Type 3 Rejected/Replacement image attributes to DX or Mammography Image module, withdrawn).
· Supplement 65: Chest CAD SR SOP Class, to standardize the reporting of CAD results for analysis of chest x-ray and/or CT images, using DICOM Structured Reporting; requested and approved April 2001.
· Definition of SR templates / SOP Class for a General Mammography report (generated by human and/or CAD), including patient clinical history and risk factors that may be used as input by CAD devices; requested and approved April 2001.
· The security of digital mammography image data and associated reports, to prohibit and/or at least recognize alteration, is a significant clinical and regulatory issue in the United States (HIPAA) and worldwide. Follow closely the progress of the Security working group and the NEMA MII Section, Privacy and Security Committee.
· Monitor future developments in CAD research, particularly those that make the technology actively interactive with radiologists.
· Use of American College of Radiology (ACR) BI-RADSTM Third Edition, version 3.1 terminology as the basis of coded terminology for Structured Reporting for Mammography
· Use of the Mammography Quality Control Manual 1999, available from the American College of Radiology (ACR), as a basis of coded terminology for the reporting of mammography image quality characteristics
· Use of the Mammography Quality Standards Act (MQSA), a federal regulation of the United States government, as a basis of coded terminology for the reporting of mammography image quality characteristics
Secretariat NEMA
Secretary Howard Clark
Chair Kees Verduin, Philips Medical Systems
Date of Last Update: April 18, 2002
A new MR object has been developed that contains a more extensive set of descriptive attributes and makes use of a new multi-frame mechanism suitable not only for MR but also for other modalities. It is currently also adopted by CT.
WG-16 will focus on the testing and promotional aspects as well on the issues related to practical implementation into valid DICOM objects.
After this, members will request a work item for Presentation of Spectroscopy Data with WG11.
· Promote the opportunities and implementation of the supplement.
· The Final Text of Supplement 49 was approved on April 26.
· None.
· None
Challenges:
· Education about and demonstration of the implementation of Supplement 49 is seen as one of the most attractive ways of keeping the momentum that the working group has initiated in vendor applications. A vendor independent demonstration tool will have to support this during the next year and a half. It is expected that after this period sufficient implementations will be available to further promote the application of the new objects. The challenge is to find an MR vendor-independent contractor that can make an evaluation tool with sufficient functionality and quality in time.
· MR applications are constantly being refined. A large number of defined terms have been standardized, but new terms should be added through CPs as soon as new techniques emerge in order to support interoperability.
Opportunities:
· NEMA’s Committee for the Advancement of DICOM supports the promotion of Supplement 49.
Secretariat NEMA
Secretary Richard Eaton, NEMA
Chair Doug Sluis, ATL
Date of Last
Update: June 10,
2002
To extend the DICOM Standard with respect to 3D and other multi-dimensional data sets that relate to real world domains of space, time, and physical properties, both measured or derived. The general classes of DICOM capabilities required are:
· An architecture for multi-dimensional data and the mapping of dimensions and data values to real- world physical domains (Supplement 63). Other working groups can use this architecture to define specific SOP Classes (e.g. WG12’s 3D ultrasound SOP Class) or to define general purpose SOP Classes, e.g. volumetric tissue classifications.
· A Storage SOP Class to specify the spatial relationship between SOP instances (data fusion).
· Presentation State and annotation for multi-dimensional storage SOP Classes.
· Structured reports for evidence from multi-dimensional IOD’s.
Representative applications include: connectivity for 3D and 4D imaging modalities; data fusion; tissue classification and segmentation; Computer Assisted Detection; quantification; treatment planning; and intra-operative applications/Image Guided Therapy.
· Complete Supplement 73 Registration (estimated Public Comment September-November of 2002).
· Complete Supplement 63 (estimated Public Comment early 2003).
· Begin additional work items after Sup63 is public comment (e.g. segmentation/classification SOP Class).
· Collaborate with WG11 on presentation.
· Develop SR extensions for reporting from multi-dimensional objects.
· Move Supplement 73 and 63 to Public Comment Status.
· A draft copy of Sup63 is in preparation.
· A draft copy of Sup73 is nearly ready for Public Comment.
· Presentation is deferred indefinitely.
· Evaluation is underway for a segmentation SOP Class.
· WG12 has begun using Sup63 to develop a 3D ultrasound SOP Class (Sup43).
· Multi-dimensional storage SOP Class.
· There exists a technical challenge to develop a normative mechanism express constraints on the architecture.
· Presentation is complex and will require significant resources, and coordination with other working groups.
· There is significant opportunity to simplify interoperability with a simple, unified architecture. Low complexity for data consumers. The low complexity, yet general-purpose architecture will greatly simplify creating implementations. Therefore, this standard is conducive to development of the 3D market.
· WG-17 has no relationship with other standards developers. WG17 is coordinating with WG12 on the 3D ultrasound supplement.
· WG-17 evaluates relevant standards (particularly in the area of presentation) to be as consistent as possible with industry familiar standards.
Secretariat National Cancer Institute
Secretary Edward Staab, NIH
Co-Chair Curtis
Langlotz, University of Pennsylvania
Co-Chair Andrew
Kraus, BioCor
Date of Last Update: November 20, 2000
To extend the DICOM Standard with respect to clinical trials information and the storage of images for educational purposes.
DICOM WG-18 was first convened in 1999 to address issues unique to the use of images in clinical trials and education. The working group elected to focus first on clinical trials before devoting significant time to education and imaging teaching files.
In its initial meetings, the Working Group determined that there are several shortcomings of the current DICOM standard when it is used in the context of clinical trials. First, there are no standard methods for “scrubbing” patient-identifying information from the DICOM header while retaining identifiers to reestablish the patient’s identity for audit purposes. Second, a variety of clinical trials attributes are missing, including the ability to capture a unique subject identifier, the protocol for which an image was obtained, and the sponsor of the clinical trial. Third, even when some of this information is stored in optional fields, the storage arrangement varies according to vendor and frequently cannot be displayed on off-the-shelf workstations. Fourth, certain common imaging parameters that are essential for the conduct of clinical trials, such as MR echo time and repetition time, are not stored in consistent locations.
The Working Group believes that the establishment of standard optional attributes for clinical trials information would assist organizations that conduct clinical trials in which images are a key component. The Working Group hopes that the establishment of DICOM standards for clinical trials information would lead to an increasing role for DICOM in submissions to the Food and Drug Administration and the National Cancer Institute, as well as other organizations that support or regulate research on medical imaging.
The Working Group has determined that it is desirable to add optional attributes to existing DICOM Image Storage Information Object Definitions (IODs) that will allow standard locations for certain basic information for clinical trials, as well as certain modality specific attributes (e.g., MR TR/TE) that are commonly encountered in clinical trials images. A work item has been approved for that purpose.
The DICOM Clinical Trials WG-18 has determined that it is desirable to add optional attributes to existing DICOM Image Storage IODs. There are two groups of attributes missing:
It is proposed to create a supplement describing the additional attributes and the information model supporting them.
Secretariat NEMA
Secretary Howard Clark, NEMA
Chair Fred Behlen, ACR
Date of Last Update: August 9, 2002
To develop DICOM and HL7 standards for image-related information for areas where the consistent use of HL7 and DICOM is of prime concern, and the coordination and mutual education and understanding between the HL7 and DICOM organizations and their technical committees/working groups.
· Contribute to HL7 Reference Information Model (RIM) any additional classes or attributes needed for representing DICOM information model.
· Work with Structured Document Technical Committee to develop document description for SR, resulting in the mapping of DICOM SR objects into CDA Level 3 documents.
· Develop messages supporting Imaging Integration.
· Modeling DICOM concepts in the HL7 Reference Information Model.
· Participation in HL7 Version 3 development to maximize compatibility between HL7 and DICOM.
· Extensions to HL7 Version 2.5 order messages to serve the needs identified in the IHE program.
· Revised Version 2 Orders Message Extension passed committee approval and was in the first V2.5 committee ballot, which closed in April of 2002. This is, now, a separate message (based on a different trigger event), Ordering Message for Imaging (OMI), rather than an additional segment on a standard Orders message. No major objections were raised in the balloting, and all minor issues have been resolved. However, due to other issues in the V2.5 ballot, the ballot did not pass, and another committee ballot will occur before full membership ballot. It is expected that the V2.5 membership ballot will be completed in January or, at the latest, April of 2003 with no further changes to the OMI message.
· The Image Reference RIM class proposal passed, with modifications, at the December 2001 HL7 RIM Harmonization meeting. Image Reference is now a clone of Act_Observation, with the dimensionality (1D, 2D, 3D, etc) pre-coordinated into the region type.
· CDA Level 3 continues to progress, but will not reach committee ballot until late in 2002.
· Increased Template activity in HL7 needs to be coordinated with DICOM.
· No current DICOM work items
· HL7 activities:
o Version 2.5 OMI Proposal. Awaiting final ballot of Version 2.5
o Version 3 mapping of DICOM procedure model.
· Linking goals to related efforts in HL7 exposes us to delays over which we may have limited control.
· A risk for DICOM is that non-DICOM visible light imaging in HL7 may compete with DICOM VL.
· A continued challenge is that most of the participants are more experienced in DICOM than in HL7. We need to find ways to encourage participation from information system vendors.
· Opportunity exists in HL7’s beginning a Templates SIG, and it will be important to coordinate HL7 and DICOM template activities. IISIG co-chair Martin Kernberg is also co-chair of the Templates SIG.
· Primary relationship as a joint working group with HL7. WG20 has the same co-chairs and membership as HL7’s Imaging Integration SIG.
· At its HL7 meeting venue, the group has regular informal contact with members of international standards groups such as ISO TC215, CEN, GEHR and HL7 international affiliates.
Secretariat NEMA
Secretary Howard Clark, NEMA
Co-Chair Stephen Metz, GE Medical Systems
Co-Chair Emil Wirsz, Siemens Medical Systems
Date of Last Update: July 6, 2001
To develop an extended
CT image object to support the many
technological and clinical advances in Computed Tomography. In particular, the increase in the number of
slices in an exam and the real-time capabilities of CT technology makes it
desirable to create a new DICOM object with a multi-frame capability. Consistency with the MR Multi-Frame IOD
under specification is important as many workstations support both CT and MR
applications. Consistency with the new
XA Multi-frame IOD is also important so that Cardiology or Angiography
applications can benefit from both CT and X-ray acquisitions.
· The Working Group is in the process of establishing its roadmap and developing the requirements for an enhanced CT IOD.
· Completion of a supplement specifying a new CT Multi-frame Image Object (Supplement 58)
· Maintenance of the CT Image IOD.
· The DICOM Committee approved this new working group in June 2000.
· The first meeting happened in September 2000. During this kick-off meeting, a joint working session was held with the MR WG-16 to ensure consistency of definition between the MR multi-frame and the CT multi-frame image objects.
· Definition of a new CT Multi-frame IOD and its associated Storage SOP Class.
· Unless an XA/RF Second Generation Multi-frame IOD definition is started, the opportunity to define a consistent multi-frame for MR, CT and X-Ray may be missed.
· Ensure rapid progress to not slow down the progress of the MR Working Group.