The SOP Classes in the Media Storage Service Class identify the Composite and Normalized IODs to be stored. The following Standard SOP Classes are identified in Table I.4-1
Table I.4-1. Media Storage Standard SOP Classes
|
SOP Class Name |
SOP Class UID |
IOD Specification (defined in PS3.3) |
|---|---|---|
|
Media Storage Directory Storage |
1.2.840.10008.1.3.10 |
|
|
Computed Radiography Image Storage |
1.2.840.10008.5.1.4.1.1.1 |
|
|
Digital X-Ray Image Storage - For Presentation |
1.2.840.10008.5.1.4.1.1.1.1 |
|
|
Digital X-Ray Image Storage - For Processing |
1.2.840.10008.5.1.4.1.1.1.1.1 |
|
|
Digital Mammography X-Ray Image Storage - For Presentation |
1.2.840.10008.5.1.4.1.1.1.2 |
|
|
Digital Mammography X-Ray Image Storage - For Processing |
1.2.840.10008.5.1.4.1.1.1.2.1 |
|
|
Digital Intra-Oral X-Ray Image Storage - For Presentation |
1.2.840.10008.5.1.4.1.1.1.3 |
|
|
Digital Intra-Oral X-Ray Image Storage - For Processing |
1.2.840.10008.5.1.4.1.1.1.3.1 |
|
|
CT Image Storage |
1.2.840.10008.5.1.4.1.1.2 |
|
|
Enhanced CT Image Storage |
1.2.840.10008.5.1.4.1.1.2.1 |
|
|
Legacy Converted Enhanced CT Image Storage |
1.2.840.10008.5.1.4.1.1.2.2 |
|
|
Ultrasound Multi-frame Image Storage |
1.2.840.10008.5.1.4.1.1.3.1 |
|
|
MR Image Storage |
1.2.840.10008.5.1.4.1.1.4 |
|
|
Enhanced MR Image Storage |
1.2.840.10008.5.1.4.1.1.4.1 |
|
|
MR Spectroscopy Storage |
1.2.840.10008.5.1.4.1.1.4.2 |
|
|
Enhanced MR Color Image Storage |
1.2.840.10008.5.1.4.1.1.4.3 |
|
|
Legacy Converted Enhanced MR Image Storage |
1.2.840.10008.5.1.4.1.1.4.4 |
|
|
Ultrasound Image Storage |
1.2.840.10008.5.1.4.1.1.6.1 |
|
|
Enhanced US Volume Storage |
1.2.840.10008.5.1.4.1.1.6.2 |
|
|
Secondary Capture Image Storage |
1.2.840.10008.5.1.4.1.1.7 |
|
|
Multi-frame Single Bit Secondary Capture Image Storage |
1.2.840.10008.5.1.4.1.1.7.1 |
|
|
Multi-frame Grayscale Byte Secondary Capture Image Storage |
1.2.840.10008.5.1.4.1.1.7.2 |
|
|
Multi-frame Grayscale Word Secondary Capture Image Storage |
1.2.840.10008.5.1.4.1.1.7.3 |
|
|
Multi-frame True Color Secondary Capture Image Storage |
1.2.840.10008.5.1.4.1.1.7.4 |
|
|
12-lead ECG Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.1.1 |
|
|
General ECG Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.1.2 |
|
|
Ambulatory ECG Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.1.3 |
|
|
Hemodynamic Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.2.1 |
|
|
Cardiac Electrophysiology Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.3.1 |
|
|
Basic Voice Audio Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.4.1 |
|
|
General Audio Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.4.2 |
|
|
Arterial Pulse Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.5.1 |
|
|
Respiratory Waveform Storage |
1.2.840.10008.5.1.4.1.1.9.6.1 |
|
|
Grayscale Softcopy Presentation State Storage |
1.2.840.10008.5.1.4.1.1.11.1 |
|
|
Color Softcopy Presentation State Storage |
1.2.840.10008.5.1.4.1.1.11.2 |
|
|
Pseudo-Color Softcopy Presentation State Storage |
1.2.840.10008.5.1.4.1.1.11.3 |
|
|
Blending Softcopy Presentation State Storage |
1.2.840.10008.5.1.4.1.1.11.4 |
|
|
XA/XRF Grayscale Softcopy Presentation State Storage |
1.2.840.10008.5.1.4.1.1.11.5 |
|
|
X-Ray Angiographic Image Storage |
1.2.840.10008.5.1.4.1.1.12.1 |
|
|
Enhanced XA Image Storage |
1.2.840.10008.5.1.4.1.1.12.1.1 |
|
|
X-Ray Radiofluoroscopic Image Storage |
1.2.840.10008.5.1.4.1.1.12.2 |
|
|
Enhanced XRF Image Storage |
1.2.840.10008.5.1.4.1.1.12.2.1 |
|
|
X-Ray 3D Angiographic Image Storage |
1.2.840.10008.5.1.4.1.1.13.1.1 |
|
|
X-Ray 3D Craniofacial Image Storage |
1.2.840.10008.5.1.4.1.1.13.1.2 |
|
|
Breast Tomosynthesis Image Storage |
1.2.840.10008.5.1.4.1.1.13.1.3 |
|
|
Intravascular Optical Coherence Tomography Image Storage - For Presentation |
1.2.840.10008.5.1.4.1.1.14.1 |
|
|
Intravascular Optical Coherence Tomography Image Storage - For Processing |
1.2.840.10008.5.1.4.1.1.14.2 |
|
|
Nuclear Medicine Image Storage |
1.2.840.10008.5.1.4.1.1.20 |
|
|
Raw Data Storage |
1.2.840.10008.5.1.4.1.1.66 |
|
|
Spatial Registration Storage |
1.2.840.10008.5.1.4.1.1.66.1 |
|
|
Spatial Fiducials Storage |
1.2.840.10008.5.1.4.1.1.66.2 |
|
|
Deformable Spatial Registration Storage |
1.2.840.10008.5.1.4.1.1.66.3 |
|
|
Segmentation Storage |
1.2.840.10008.5.1.4.1.1.66.4 |
|
|
Surface Segmentation Storage |
1.2.840.10008.5.1.4.1.1.66.5 |
|
|
Real World Value Mapping Storage |
1.2.840.10008.5.1.4.1.1.67 |
|
|
Surface Scan Mesh Storage |
1.2.840.10008.5.1.4.1.1.68.1 |
|
|
Surface Scan Point Cloud Storage |
1.2.840.10008.5.1.4.1.1.68.2 |
|
|
VL Endoscopic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.1 |
|
|
Video Endoscopic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.1.1 |
|
|
VL Microscopic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.2 |
|
|
Video Microscopic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.2.1 |
|
|
VL Slide-Coordinates Microscopic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.3 |
|
|
VL Photographic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.4 |
|
|
Video Photographic Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.4.1 |
|
|
Ophthalmic Photography 8 Bit Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.5.1 |
|
|
Ophthalmic Photography 16 Bit Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.5.2 |
|
|
Stereometric Relationship Storage |
1.2.840.10008.5.1.4.1.1.77.1.5.3 |
|
|
Ophthalmic Tomography Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.5.4 |
|
|
VL Whole Slide Microscopy Image Storage |
1.2.840.10008.5.1.4.1.1.77.1.6 |
|
|
Lensometry Measurements Storage |
1.2.840.10008.5.1.4.1.1.78.1 |
|
|
Autorefraction Measurements Storage |
1.2.840.10008.5.1.4.1.1.78.2 |
|
|
Keratometry Measurements Storage |
1.2.840.10008.5.1.4.1.1.78.3 |
|
|
Subjective Refraction Measurements Storage |
1.2.840.10008.5.1.4.1.1.78.4 |
|
|
Visual Acuity Storage Measurements Storage |
1.2.840.10008.5.1.4.1.1.78.5 |
|
|
Spectacle Prescription Report Storage |
1.2.840.10008.5.1.4.1.1.78.6 |
|
|
Ophthalmic Axial Measurements Storage |
1.2.840.10008.5.1.4.1.1.78.7 |
|
|
Intraocular Lens Calculations Storage |
1.2.840.10008.5.1.4.1.1.78.8 |
|
|
Macular Grid Thickness and Volume Report |
1.2.840.10008.5.1.4.1.1.79.1 |
|
|
Ophthalmic Visual Field Static Perimetry Measurements Storage |
1.2.840.10008.5.1.4.1.1.80.1 |
|
|
Ophthalmic Thickness Map Storage |
1.2.840.10008.5.1.4.1.1.81.1 |
|
|
Corneal Topography Map Storage |
1.2.840.10008.5.1.4.1.1.82.1 |
|
|
Basic Text SR |
1.2.840.10008.5.1.4.1.1.88.11 |
|
|
Enhanced SR |
1.2.840.10008.5.1.4.1.1.88.22 |
|
|
Comprehensive SR |
1.2.840.10008.5.1.4.1.1.88.33 |
|
|
Comprehensive 3D SR |
1.2.840.10008.5.1.4.1.1.88.34 |
|
|
Procedure Log |
1.2.840.10008.5.1.4.1.1.88.40 |
|
|
Mammography CAD SR |
1.2.840.10008.5.1.4.1.1.88.50 |
|
|
Key Object Selection Document |
1.2.840.10008.5.1.4.1.1.88.59 |
|
|
Chest CAD SR |
1.2.840.10008.5.1.4.1.1.88.65 |
|
|
X-Ray Radiation Dose SR |
1.2.840.10008.5.1.4.1.1.88.67 |
|
|
Colon CAD SR |
1.2.840.10008.5.1.4.1.1.88.69 |
|
|
Implantation Plan SR Document Storage |
1.2.840.10008.5.1.4.1.1.88.70 |
|
|
Encapsulated PDF Storage |
1.2.840.10008.5.1.4.1.1.104.1 |
|
|
Encapsulated CDA Storage |
1.2.840.10008.5.1.4.1.1.104.2 |
|
|
Positron Emission Tomography Image Storage |
1.2.840.10008.5.1.4.1.1.128 |
|
|
Enhanced PET Image Storage |
1.2.840.10008.5.1.4.1.1.130 |
|
|
Legacy Converted Enhanced PET Image Storage |
1.2.840.10008.5.1.4.1.1.128.1 |
|
|
Basic Structured Display Storage |
1.2.840.10008.5.1.4.1.1.131 |
|
|
RT Image Storage |
1.2.840.10008.5.1.4.1.1.481.1 |
|
|
RT Dose Storage |
1.2.840.10008.5.1.4.1.1.481.2 |
|
|
RT Structure Set Storage |
1.2.840.10008.5.1.4.1.1.481.3 |
|
|
RT Beams Treatment Record Storage |
1.2.840.10008.5.1.4.1.1.481.4 |
|
|
RT Plan Storage |
1.2.840.10008.5.1.4.1.1.481.5 |
|
|
RT Brachy Treatment Record Storage |
1.2.840.10008.5.1.4.1.1.481.6 |
|
|
RT Treatment Summary Record Storage |
1.2.840.10008.5.1.4.1.1.481.7 |
|
|
RT Ion Plan Storage |
1.2.840.10008.5.1.4.1.1.481.8 |
|
|
RT Ion Beams Treatment Record Storage |
1.2.840.10008.5.1.4.1.1.481.9 |
|
|
RT Beams Delivery Instruction Storage |
1.2.840.10008.5.1.4.34.7 |
|
|
Hanging Protocol Storage |
1.2.840.10008.5.1.4.38.1 |
|
|
Color Palette Storage |
1.2.840.10008.5.1.4.39.1 |
|
|
Generic Implant Template Storage |
1.2.840.10008.5.1.4.43.1 |
|
|
Implant Assembly Template Storage |
1.2.840.10008.5.1.4.44.1 |
|
|
Implant Template Group Storage |
1.2.840.10008.5.1.4.45.1 |
Except for the Media Storage Directory SOP Classes, the above listed Media Storage Standard SOP Classes are assigned the same UID Value as the corresponding network communication SOP Classes. This was done to simplify UID assignment. Although these SOP Classes are based on different Operations, the context of their usage should unambiguously distinguish a Media Storage SOP Class from a Network communication SOP Class.
The storage of Normalized Print SOP Instances on media was previously defined in DICOM. They have been retired. See PS 3.4-1998.
The storage of Detached and Standalone SOP Instances on media was previously defined in DICOM. They have been retired. See PS 3.4-2004
See Annex N.
The requirements of Annex O apply to the following SOP Classes:
Basic Text SR
Enhanced SR
Comprehensive SR
Comprehensive 3D SR
Mammography CAD SR
Chest CAD SR
Procedure Log
X-Ray Radiation Dose SR
Spectacle Prescription Report
Colon CAD SR
Macular Grid Thickness and Volume Report
Implantation Plan SR Document
Annex O requirements do not apply to the Key Object Selection Document SOP Class.