MMM.2 CT Example with Images and Presentation States

This example presumes that the Q/R SCP contains the same images and presentation states described in Annex LLL.

MMM.2.1 C-FIND and C-MOVE At Study Level With Classic View

Study Root Study Level C-FIND Request with Patient ID and Accession Number as keys:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Study Date

(0008,0020)

DA

0

Study Time

(0008,0030)

TM

0

Accession Number

(0008,0050)

SH

10

2263295914110886

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

8

CLASSIC

Modalities in Study

(0008,0061)

CS

0

SOP Classes in Study

(0008,0062)

UI

0

Referring Physician's Name

(0008,0090)

PN

0

Study Description

(0008,1030)

LO

0

Physicians of Record

(0008,1048)

PN

0

Name of Physicians Reading Study

(0008,1060)

PN

0

Admitting Diagnoses Description

(0008,1080)

LO

0

Patient's Name

(0010,0010)

PN

0

Patient's ID

(0010,0020)

LO

10

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

0

Patient's Birth Time

(0010,0032)

TM

0

Patient's Sex

(0010,0040)

CS

0

Patient's Age

(0010,1010)

AS

0

Patient's Size

(0010,1020)

DS

0

Patient's Weight

(0010,1030)

DS

0

Occupation

(0010,2180)

SH

0

Additional Patient History

(0010,21b0)

LT

0

Patient Comments

(0010,4000)

LT

0

Study Instance UID

(0020,000d)

UI

0

Study ID

(0020,0010)

SH

0

Other Study Numbers

(0020,1070)

IS

0

Number of Study Related Series

(0020,1206)

IS

0

Number of Study Related Instances

(0020,1208)

IS

0

Study Root Study Level C-FIND Response:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Study Date

(0008,0020)

DA

8

20061230

Study Time

(0008,0030)

TM

6

100000

Accession Number

(0008,0050)

SH

10

2263295914110886

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

8

CLASSIC

Modalities in Study

(0008,0061)

CS

6

CT\PR

SOP Classes in Study

(0008,0062)

UI

36

1.2.840.10008.5.1.4.1.1.11.1​\1.2.840.10008.5.1.4.1.1.2

Referring Physician's Name

(0008,0090)

PN

0

Study Description

(0008,1030)

LO

0

Physicians of Record

(0008,1048)

PN

0

Name of Physicians Reading Study

(0008,1060)

PN

0

Admitting Diagnoses Description

(0008,1080)

LO

0

Patient's Name

(0010,0010)

PN

6

277654

Patient's ID

(0010,0020)

LO

10

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

8

19301018

Patient's Birth Time

(0010,0032)

TM

0

Patient's Sex

(0010,0040)

CS

0

Patient's Age

(0010,1010)

AS

0

Patient's Size

(0010,1020)

DS

0

Patient's Weight

(0010,1030)

DS

0

Occupation

(0010,2180)

SH

0

Additional Patient History

(0010,21b0)

LT

0

Patient Comments

(0010,4000)

LT

0

Study Instance UID

(0020,000d)

UI

3e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Study ID

(0020,0010)

SH

4

1234

Other Study Numbers

(0020,1070)

IS

0

Number of Study Related Series

(0020,1206)

IS

2

2

Number of Study Related Instances

(0020,1208)

IS

2

3

Study Root Study Level C-MOVE Request with Study Instance UID as unique key:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

8

CLASSIC

Study Instance UID

(0020,000d)

UI

3e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Study Root Study Level C-MOVE Pending Responses illustrating SOP Instances retrieved:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Affected SOP Class UID

(0000,0002)

UI

1c

1.2.840.10008.5.1.4.1.1.11.1

Affected SOP Instance UID

(0000,1000)

UI

38

1.2.276.0.7230010.3.1.4.2989371993.3196.1272478982.1246

Affected SOP Class UID

(0000,0002)

UI

1a

1.2.840.10008.5.1.4.1.1.2

Affected SOP Instance UID

(0000,1000)

UI

3e

1.3.6.1.4.1.9328.50.1.​118458571690318148036673922876743615666

Affected SOP Class UID

(0000,0002)

UI

1a

1.2.840.10008.5.1.4.1.1.2

Affected SOP Instance UID

(0000,1000)

UI

3c

1.3.6.1.4.1.9328.50.1.​21169049221871725649891126757390969029

Note

Only the Classic image instances and the original Presentation State that refers to it are transferred with this STUDY level request.

MMM.2.2 C-FIND and C-MOVE at Study Level with Enhanced View

Study Root Study Level C-FIND Request with Patient ID and Accession Number as keys:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Study Date

(0008,0020)

DA

0

Study Time

(0008,0030)

TM

0

Accession Number

(0008,0050)

SH

10

2263295914110886

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

a

ENHANCED

Modalities in Study

(0008,0061)

CS

0

SOP Classes in Study

(0008,0062)

UI

0

Referring Physician's Name

(0008,0090)

PN

0

Study Description

(0008,1030)

LO

0

Physicians of Record

(0008,1048)

PN

0

Name of Physicians Reading Study

(0008,1060)

PN

0

Admitting Diagnoses Description

(0008,1080)

LO

0

Patient's Name

(0010,0010)

PN

0

Patient's ID

(0010,0020)

LO

10

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

0

Patient's Birth Time

(0010,0032)

TM

0

Patient's Sex

(0010,0040)

CS

0

Patient's Age

(0010,1010)

AS

0

Patient's Size

(0010,1020)

DS

0

Patient's Weight

(0010,1030)

DS

0

Occupation

(0010,2180)

SH

0

Additional Patient History

(0010,21b0)

LT

0

Patient Comments

(0010,4000)

LT

0

Study Instance UID

(0020,000d)

UI

0

Study ID

(0020,0010)

SH

0

Other Study Numbers

(0020,1070)

IS

0

Number of Study Related Series

(0020,1206)

IS

0

Number of Study Related Instances

(0020,1208)

IS

0

Note

This is exactly the same as for the CLASSIC view, except that Query/Retrieve View (0008,0053) has a value of ENHANCED rather than CLASSIC.

Study Root Study Level C-FIND Response:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Study Date

(0008,0020)

DA

8

20061230

Study Time

(0008,0030)

TM

6

100000

Accession Number

(0008,0050)

SH

10

2263295914110886

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

a

ENHANCED

Modalities in Study

(0008,0061)

CS

6

CT\PR

SOP Classes in Study

(0008,0062)

UI

3a

1.2.840.10008.5.1.4.1.1.11.1​\1.2.840.10008.5.1.4.1.1.2.2

Referring Physician's Name

(0008,0090)

PN

0

Study Description

(0008,1030)

LO

0

Physicians of Record

(0008,1048)

PN

0

Name of Physicians Reading Study

(0008,1060)

PN

0

Admitting Diagnoses Description

(0008,1080)

LO

0

Patient's Name

(0010,0010)

PN

6

277654

Patient's ID

(0010,0020)

LO

10

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

8

19301018

Patient's Birth Time

(0010,0032)

TM

0

Patient's Sex

(0010,0040)

CS

0

Patient's Age

(0010,1010)

AS

0

Patient's Size

(0010,1020)

DS

0

Patient's Weight

(0010,1030)

DS

0

Occupation

(0010,2180)

SH

0

Additional Patient History

(0010,21b0)

LT

0

Patient Comments

(0010,4000)

LT

0

Study Instance UID

(0020,000d)

UI

3e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Study ID

(0020,0010)

SH

4

1234

Other Study Numbers

(0020,1070)

IS

0

Number of Study Related Series

(0020,1206)

IS

2

2

Number of Study Related Instances

(0020,1208)

IS

2

2

Note

This is the same as for the CLASSIC view, except that Query/Retrieve View (0008,0053) has a value of ENHANCED rather than CLASSIC, the SOP Classes in Study (0008,0062) has a different value for the Image Storage SOP Class, and the Number of Study Related Instances (0020,1208) is fewer.

Study Root Study Level C-MOVE Request with Study Instance UID as unique key:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

a

ENHANCED

Study Instance UID

(0020,000d)

UI

3e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Note

This is exactly the same as for the CLASSIC view, except that Query/Retrieve View (0008,0053) has a value of ENHANCED rather than CLASSIC. In particular, the same Study Instance UID is retrieved.

Study Root Study Level C-MOVE Pending Responses illustrating SOP Instances retrieved:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Affected SOP Class UID

(0000,0002)

UI

1c

1.2.840.10008.5.1.4.1.1.11.1

Affected SOP Instance UID

(0000,1000)

UI

38

1.3.6.1.4.1.5962.1.1.0.0.0.1344614718.10917.0

Affected SOP Class UID

(0000,0002)

UI

1a

1.2.840.10008.5.1.4.1.1.2.2

Affected SOP Instance UID

(0000,1000)

UI

3c

1.3.6.1.4.1.5962.99.1.2830.2144.​1344607895685.1.1.1234.8.1

Note

Only the converted instances are transferred with this STUDY level request, including the Legacy Enhanced image and the converted Presentation State with updated UID references.