M.2 Vascular Examples

The following are simple, non-comprehensive illustrations of significant report sections.

M.2.1 Example 1: Renal Vessels

Nest

Code Meaning of Concept Name

Code Meaning or Example Value

TID

1

Vascular Ultrasound Procedure Report

TID 5100

1.1

Language of Content Item and Descendants

English

TID 1204

1.2

Subject Name

John Doe

TID 1007

1.3

Subject ID

123-45-9876

TID 1007

1.4

Procedure Study Instance UID

1.2.842.111724.7678.12.33

TID 1005

1.5

Procedure Study Component UID

1.2.842.111724.7678.55.33

TID 1005

1.6

Procedure Accession Number

20011007-21

TID 1005

1.7

Patient Characteristics

TID 5101

1.7.n

TID 5101

1.8

Summary

TID 5102

1.8.n

TID 5102

1.9

Findings

TID 5103

1.9.1

Finding Site

Vascular Structure Of Kidney

TID 5103

1.9.2

Laterality

Right

TID 5103

1.9.3

Renal Artery

TID 5104

1.9.3.1

Topographical Modifier

Origin

TID 5104

1.9.3.2

Peak Systolic Velocity

420 cm/s

TID 300

1.9.3.3

End Diastolic Velocity

120 cm/s

TID 300

1.9.3.4

Resistive Index

3.7

TID 300

1.9.3.5

Pulsatility Index

0.7

TID 300

1.9.3.6

Systolic to Diastolic Velocity Ratio

3.5

TID 300

1.9.4

Renal Artery

TID 5104

1.9.4.1

Topographical Modifier

Proximal

TID 5104

1.9.4.n

. . . other measurements

TID 300

1.9.5

Renal Artery

TID 5104

1.9.5.1

Topographical Modifier

Middle

TID 5104

1.9.5.n

. . . other measurements

TID 300

1.9.6

Renal Artery

TID 5104

1.9.6.1

Topographical Modifier

Distal

TID 5104

1.9.6.n

. . . other measurements

TID 300

1.9.7

Renal Vein

TID 5104

1.9.7.1

Topographical Modifier

Middle

TID 5104

1.9.7.2

Peak Systolic Velocity

120 cm/s

TID 300

1.9.7.n

. . . other measurements

TID 300

1.9.8

Renal Artery/Aorta Velocity Ratio

2.9

TID 5103

1.9.n

other renal vessels

TID 5104

1.10

Findings

TID 5103

1.10.1

Finding Site

Vascular Structure of Kidney

TID 5103

1.10.2

Laterality

Left

TID 5103

TID 5104

M.2.2 Example 2: Carotids Extracranial

Nest

Code Meaning of Concept Name

Code Meaning or Example Value

TID

1

Vascular Ultrasound Procedure Report

TID 5100

1.n

….

TID 5100

1.10

Findings

TID 5103

1.10.1

Findings Site

Artery of neck

TID 5103

1.10.2

Laterality

Right

TID 5103

1.10.3

Common Carotid Artery

TID 5104

1.10.3.1

Topographical Modifier

Proximal

TID 5104

1.10.3.2

Peak Systolic Velocity

80 cm/s

TID 300

1.10.3.3

Peak Systolic Velocity

88 cm/s

TID 300

1.10.3.4

Peak Systolic Velocity

84 cm/s

TID 300

1.10.3.4.1

Derivation

Mean

TID 300

1.10.4

Common Carotid Artery

TID 5104

1.10.4.1

Topographical Modifier

Middle

TID 5104

1.10.4.2

Peak Systolic Velocity

180 cm/s

TID 300

1.10.5

Common Carotid Artery

TID 5104

1.10.5.1

Topographical Modifier

Distal

TID 5104

1.10.5.2

Peak Systolic Velocity

180 cm/s

TID 300

1.10.6

Carotid bulb

TID 5104

1.10.6.1

Peak Systolic Velocity

190 cm/s

TID 300

1.10.7

Internal Carotid Artery

TID 5104

1.10.7.1

Topographical Modifier

Proximal

TID 5104

1.10.7.2

Peak Systolic Velocity

180 cm/s

TID 300

1.10.8

Internal Carotid Artery

TID 5104

1.10.8.1

Topographical Modifier

Distal

TID 5104

1.10.8.2

Peak Systolic Velocity

180 cm/s

TID 300

1.10.9

ICA/CCA velocity ratio

1.5

TID 5103

1.10.n

….

TID 300

1.11

Findings

TID 5103

1.11.1

Finding Site

Artery of neck

TID 5103

1.11.2

Laterality

Left

TID 5103

….