This template collects a patient's relevant information as it relates to breast imaging. This template, together with its subordinate templates, describes the history of a patient's reproductive system, hormone medications, past procedures, risk factors, and indicated problems as they relate to breast health.
Extensible
Significant
Table TID 9000. Relevant Patient Information for Breast Imaging
This general template collects the details of a patient's reproductive system history, such as number of births, and gynecological surgery history.
Extensible
Significant
Table TID 9001. Gynecological History
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINER |
EV (R-20767, SRT, "Gynecological History") |
1 |
M |
||||
2 |
> |
HAS OBS CONTEXT |
CODE |
1 |
U |
|||
3 |
> |
CONTAINS |
DATE |
1 |
U |
|||
4 |
> |
CONTAINS |
NUM |
EV (111518, DCM, "Age when first menstrual period occurred") |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
|
5 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
6 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
7 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
8 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
9 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
10 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
11 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
12 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
13 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
||
14 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
15 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
16 |
>> |
HAS CONCEPT MOD |
CODE |
EV (R-404ED, SRT, "Extent") |
1 |
U |
EV (R-404F1, SRT, "Complete") EV (R-404FE, SRT, "Partial") |
|
17 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
18 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
19 |
> |
CONTAINS |
CODE |
1 |
U |
|||
20 |
>> |
HAS PROPERTIES |
NUM |
1 |
U |
UNITS = EV (wk, UCUM, "Week") |
||
21 |
> |
CONTAINS |
CODE |
1 |
U |
|||
22 |
> |
CONTAINS |
CODE |
1 |
U |
This general template provides detailed information on a patient's medication or substance use, or exposure to environmental factors, including type and duration of use or exposure.
Table TID 9002. Parameters
Parameter Name |
Parameter Usage |
---|---|
$ContainerConcept |
Coded term for the concept name of the CONTAINER, identifying it as medication, substance, or environmental exposure history. |
$CodeConcept |
Coded term for the concept name of the CODE, identifying it as medication, substance, or environmental exposure. |
$CodeValue |
Coded term or Context Group for value of the medication, substance, or environmental exposure. |
Extensible
Significant
Table TID 9002. Medication, Substance, Environmental Exposure
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINER |
$ContainerConcept |
1 |
M |
||||
2 |
> |
CONTAINS |
CODE |
$CodeConcept |
1-n |
M |
$CodeValue |
|
3 |
>> |
HAS CONCEPT MOD |
CODE |
EV (G-C032, SRT, "Classification") |
1 |
U |
||
4 |
>> |
HAS OBS CONTEXT |
CODE |
1 |
U |
|||
5 |
>> |
HAS PROPERTIES |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
6 |
>> |
HAS PROPERTIES |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
7 |
>> |
HAS PROPERTIES |
DATETIME |
1 |
U |
|||
8 |
>> |
HAS PROPERTIES |
DATETIME |
1 |
U |
|||
9 |
>> |
HAS PROPERTIES |
NUM |
EV (G-7290, SRT, "Duration") |
1 |
U |
||
10 |
>> |
HAS PROPERTIES |
CODE |
1 |
U |
|||
11 |
>> |
HAS PROPERTIES |
TEXT |
1 |
U |
|||
12 |
>> |
HAS PROPERTIES |
NUM |
1 |
U |
The unit of measure shall be quantity per unit of time |
||
13 |
>> |
HAS PROPERTIES |
CODE |
1 |
U |
|||
14 |
>> |
HAS PROPERTIES |
CODE |
DCID 6094 “Qualitative Concepts for Usage, Exposure Frequency” |
1 |
U |
Content Item Descriptions
Row 3 "Classification" |
No context group is provided for the value set, but it is recommended that values from a standard external coding scheme, such as SRT or NDC, be used. |
Rows 13 & 14 |
If both of these content items are instantiated, the concept names selected for each should match. For example, use "Relative dose amount" as the concept name for row 13 with "Relative dose frequency" as the concept name for row 14. |
This general template provides detailed information on a patient's previous procedure, surgery, or treatment.
Table TID 9003. Parameters
Parameter Name |
Parameter Usage |
---|---|
$ProcedureList |
Coded term or Context Group for value of Previous Procedure |
$ProcedureModifier |
Coded term or Context Group for value of Previous Procedure Modifier |
$NumConceptName |
Coded term or Context Group for the concept name of a numeric property of the Previous Procedure |
$LateralityValue |
Coded term or Context Group for value of Laterality |
$ProcedureResult |
Coded term or Context Group for value of Result of Procedure |
$ComplicationValue |
Coded term or Context Group for value of Complication |
Extensible
Significant
Table TID 9003. Previous Procedure
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINER |
1 |
M |
|||||
2 |
> |
CONTAINS |
CODE |
1-n |
M |
$ProcedureList |
||
3 |
>> |
HAS CONCEPT MOD |
CODE |
1-n |
U |
$ProcedureModifier |
||
4 |
>> |
HAS OBS CONTEXT |
CODE |
1 |
U |
|||
5 |
>> |
HAS PROPERTIES |
NUM |
$NumConceptName |
1-n |
U |
||
6 |
>> |
HAS PROPERTIES |
CODE |
EV (G-C171, SRT, "Laterality") |
1 |
U |
$LateralityValue |
|
7 |
>> |
HAS PROPERTIES |
DATETIME |
1 |
UC |
XOR row 8 |
||
8 |
>> |
HAS PROPERTIES |
CODE |
1 |
UC |
XOR row 7 |
||
9 |
>> |
HAS PROPERTIES |
NUM |
EV (R-42009, SRT, "Number of occurrences") |
1 |
U |
UNITS = EV (1, UCUM, "no units") |
|
10 |
>> |
HAS PROPERTIES |
CODE |
EV (DD-60002, SRT, "Complication of procedure") |
1-n |
U |
$ComplicationValue |
|
11 |
>>> |
HAS PROPERTIES |
CODE |
1 |
U |
|||
12 |
>> |
HAS PROPERTIES |
CODE |
1 |
U |
$ProcedureResult |
||
13 |
>> |
HAS PROPERTIES |
INCLUDE |
1-n |
U |
This general template provides information about indicated problems presented by a patient. For example, indicated breast problems relating to the purpose for a mammographic examination.
Table TID 9004. Parameters
Parameter Name |
Parameter Usage |
---|---|
$ProblemList |
Coded term or Context Group for value of Indicated Problem |
$LateralityValue |
Coded term or Context Group for value of Laterality |
$LocationValue |
Coded term or Context Group for value of Location |
Extensible
Significant
Table TID 9004. Indicated Problem
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINER |
1 |
M |
|||||
2 |
> |
CONTAINS |
CODE |
1-n |
M |
$ProblemList |
||
3 |
>> |
HAS OBS CONTEXT |
CODE |
1 |
U |
|||
4 |
>> |
HAS OBS CONTEXT |
DATETIME |
1 |
U |
|||
5 |
>> |
HAS PROPERTIES |
CODE |
EV (G-C171, SRT, "Laterality") |
1 |
U |
$LateralityValue |
|
6 |
>> |
HAS PROPERTIES |
CODE |
EV (G-C0E3, SRT, "Finding site") |
1 |
U |
$LocationValue |
|
7 |
>> |
HAS PROPERTIES |
NUM |
EV (G-7290, SRT, "Duration") |
1 |
U |
||
8 |
>> |
HAS PROPERTIES |
CODE |
EV (R-407E7, SRT, "Frequency") |
1 |
U |
||
9 |
>> |
HAS PROPERTIES |
DATETIME |
1 |
U |
|||
10 |
>> |
HAS PROPERTIES |
TEXT |
1 |
U |
This general template provides detailed information on the risk factors for a patient, related to medical history for themselves and family members.
Table TID 9005. Parameters
Parameter Name |
Parameter Usage |
---|---|
$RiskList |
Coded term or Context Group for value of Risk Factor |
$FamilyList |
Coded term or Context Group for value of Family Member with Risk Factor |
Extensible
Significant
Table TID 9005. Risk Factor
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINER |
1 |
M |
|||||
2 |
> |
CONTAINS |
CODE |
EV (F-01500, SRT, "Risk factor") |
1-n |
M |
$RiskList |
|
3 |
>> |
HAS CONCEPT MOD |
CODE |
1 |
U |
EV (G-0002, SRT, "Family history of") |
||
4 |
>> |
HAS PROPERTIES |
NUM |
1 |
UC |
IFF value of row 2 is (G-0305, SRT, "History of - premature delivery") |
||
5 |
>> |
HAS OBS CONTEXT |
CODE |
1 |
U |
|||
6 |
>> |
HAS PROPERTIES |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
7 |
>> |
HAS PROPERTIES |
NUM |
EV (G-7290, SRT, "Duration") |
1 |
U |
||
8 |
>> |
HAS PROPERTIES |
TEXT |
1 |
U |
|||
9 |
>> |
INFERRED FROM |
CODE |
1-n |
U |
$FamilyList |
||
10 |
>>> |
HAS PROPERTIES |
NUM |
1 |
U |
UNITS = EV (a, UCUM, "Year") |
||
11 |
>>> |
HAS CONCEPT MOD |
CODE |
1 |
U |
|||
12 |
>>> |
HAS CONCEPT MOD |
CODE |
1 |
U |
This general template collects the details of a patient's obstetric history for a current pregnancy. Information regarding previous pregnancies is conveyed using the Gynecological History Template.
Extensible
Significant
Table TID 9006. Obstetric History
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINS |
CONTAINER |
EV (R-20658, SRT, "Obstetric History") |
1 |
M |
|||
2 |
> |
CONTAINS |
DATE |
1-n |
U |
|||
3 |
> |
CONTAINS |
NUM |
1 |
U |
UNITS = EV (d, UCUM, "day") |
||
4 |
> |
CONTAINS |
TEXT |
1-n |
U |
Content Item Descriptions
Row 3 "Gestational Age" |
Observation DateTime (0040,A032) for Content Item shall be present, in order to convey the date and time at which this Gestational Age was established. |
This template collects a patient's relevant information for general purpose use. This template, together with its subordinate templates, describes the history of a patient's reproductive system, medications, substance use, environmental exposure, past procedures, risk factors, and indicated problems.
Extensible
Significant
Table TID 9007. General Relevant Patient Information
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Type |
Condition |
Value Set Constraint |
|
---|---|---|---|---|---|---|---|---|
1 |
CONTAINER |
1 |
M |
|||||
2 |
> |
HAS CONCEPT MOD |
INCLUDE |
1 |
M |
|||
3 |
> |
CONTAINS |
INCLUDE |
1 |
U |
|||
4 |
> |
CONTAINS |
INCLUDE |
1 |
U |
$ContainerConcept = EV (10160-0, LN, "History Of Medication Use") $CodeConcept = EV (111516, DCM, "Medication Type") |
||
5 |
> |
CONTAINS |
INCLUDE |
1 |
U |
$ContainerConcept = EV (111545, DCM, "Substance Use History") $CodeConcept = EV (111546, DCM, "Used Substance Type") $CodeValue = BCID 6089 “Substances” |
||
6 |
> |
CONTAINS |
INCLUDE |
1 |
U |
$ContainerConcept = EV (111547, DCM, "Environmental Exposure History") $CodeConcept = EV (111548, DCM, "Environmental Factor") |
||
7 |
> |
CONTAINS |
INCLUDE |
1 |
U |
$LateralityValue = BCID 244 "Laterality" |
||
8 |
> |
CONTAINS |
INCLUDE |
1 |
U |
$LateralityValue = BCID 244 "Laterality" |
||
9 |
> |
CONTAINS |
INCLUDE |
1 |
U |
$RiskList = BCID 6087 “General Risk Factors” $FamilyList = DCID 7451 “Family Member” |
||
10 |
> |
CONTAINS |
INCLUDE |
1 |
U |
|||
11 |
> |
CONTAINS |
INCLUDE |
1 |
U |
|||
12 |
> |
CONTAINS |
INCLUDE |
1 |
U |
|||
13 |
> |
CONTAINS |
INCLUDE |
1 |
U |