This Context Group comprises the ECG lead placement system identifiers of ISO/IEEE 11073-10102. The terms included in the table below may not constitute the complete list; see the ISO/IEEE Standard.
Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.
Extensible
20080927
Table CID 3263. Electrode Placement Values
Coding Scheme |
Code Value |
Code Meaning |
ISO/IEEE 11073 MDC Equivalent Reference ID (Informative) |
---|---|---|---|
MDC |
10:11264 |
Unspecified 12-lead system |
MDC_ECG_LDSYS_12LD_UNSPECIFIED |
MDC |
10:11265 |
Standard 12-lead positions, electrodes placed individually |
MDC_ECG_LDSYS_12LD_STD |
MDC |
10:11266 |
Mason-Likar lead positions, electrodes placed individually |
MDC_ECG_LDSYS_12LD_MASON_LIKAR |
MDC |
10:11267 |
Mason-Likar lead positions, V1-V6 in electrode pad |
MDC_ECG_LDSYS_12LD_VPAD |
MDC |
10:11268 |
12-lead electrode pad |
MDC_ECG_LDSYS_12LD_PAD |
MDC |
10:11269 |
12-lead derived from Frank XYZ leads |
MDC_ECG_LDSYS_12LD_FROM_FRANK |
MDC |
10:11270 |
12-lead derived from non-standard leads |
MDC_ECG_LDSYS_12LD_NON_STANDARD |
MDC |
10:11271 |
12-lead for bicycle exercise testing, limb leads on back of patient |
MDC_ECG_LDSYS_12LD_BICYCLE |
MDC |
10:11272 |
Standard 12-lead positions one intercostal space higher |
MDC_ECG_LDSYS_12LD_RAISED_INTERCOSTAL |
MDC |
10:11273 |
Unspecified XYZ lead system |
MDC_ECG_LDSYS_XYZ_UNSPECIFIED |
MDC |
10:11274 |
Frank XYZ lead system |
MDC_ECG_LDSYS_XYZ_FRANK |
MDC |
10:11275 |
McFee-Parungao XYZ lead system |
MDC_ECG_LDSYS_XYZ_MCFEE_PARUNAGO |
MDC |
10:11276 |
Cube XYZ lead system |
MDC_ECG_LDSYS_XYZ_CUBE |
MDC |
10:11277 |
Bipolar uncorrected XYZ lead system |
MDC_ECG_LDSYS_XYZ_BIPOLAR |
MDC |
10:11278 |
Pseudo-orthogonal XYZ lead system |
MDC_ECG_LDSYS_XYZ_PSEUDO_ORTH |
MDC |
10:11279 |
XYZ leads derived from standard 12-lead |
MDC_ECG_LDSYS_XYZ_FROM_12LD |
MDC |
10:11280 |
NEHB lead system |
MDC_ECG_LDSYS_3LD_NEHB |
MDC |
10:11281 |
3-lead system, CC5-CM5-ML |
MDC_ECG_LDSYS_3LD_CC5_CM5_ML |
MDC |
10:11282 |
3-lead system, CC5-CM5-CH5 |
MDC_ECG_LDSYS_3LD_CM5_CC5_CH5 |
MDC |
10:11283 |
12-lead from Frank leads XYZ leads by Dower transformation |
MDC_ECG_LDSYS_12LD_FROM_DOWER |
MDC |
10:11284 |
12-lead from EASI leads (ES, AS, AI) by Dower/EASI transformation |
MDC_ECG_LDSYS_12LD_FROM_EASI |
MDC |
10:11285 |
12-lead from Limb Leads (I, II) and one or more V leads |
MDC_ECG_LDSYS_12LD_FROM_LIMB |
MDC |
10:11286 |
Standard 12-lead and XYZ |
MDC_ECG_LDSYS_12LD_STD_AND_XYZ |
MDC |
10:11287 |
Standard 12-lead and NEHB |
MDC_ECG_LDSYS_12LD_STD_AND_NEHB |
MDC |
10:11288 |
Standard 12-lead and CC5-CM5-ML |
MDC_ECG_LDSYS_12LD_STD_AND_CC5_CM5_ML |
MDC |
10:11289 |
Standard 12-lead and CM5-CC5-CH5 |
MDC_ECG_LDSYS_12LD_STD_AND_CM5_CC5_CH5 |
MDC |
10:11290 |
Standard 12-lead with extra leads to the right and/or left sides |
MDC_ECG_LDSYS_12LD_STD_EXTD |
MDC |
10:11291 |
Standard 12-lead extended to the right by V5R, V4R, V3R |
MDC_ECG_LDSYS_12LD_STD_EXTD_RIGHT |
MDC |
10:11292 |
Standard 12-lead extended to the left by V7, V8, V9 |
MDC_ECG_LDSYS_12LD_STD_EXTD_LEFT |
A prior version of this context group used codes from the SCP-ECG vocabulary.